Summary
PRRES20252932
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX. UNFINISHED BASEMENT. ROOF TRUSSES.
07/10/2025
07/21/2025
01/11/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
taylor@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,584.63 $2,584.63 Paid 07/21/2025
Water Tap Fee $8,160.00 $8,160.00 Paid 07/21/2025
Water Meter Fee $1,583.06 $1,583.06 Paid 07/21/2025
Sanitary Sewer Development Fee $4,796.00 $4,796.00 Paid 07/21/2025
Right of Way Permit Fee $85.00 $85.00 Paid 07/21/2025
Parks Impact Fee Residential Zone 2 $1,500.00 $1,500.00 Paid 07/21/2025
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 07/21/2025
$0.00 $0.00 $0.00 Not payable online N/A
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Erosion Control Inspection Residential Pending
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Underslab Electrical Inspection - Residential Pending
Rated Assembly Inspection Pending
Occupancy Inspection - Codes Residential Pending
Gas Service Inspection - Residential Pending
Misc
Corrective Action Required
10/29/2025
No pressure at gauge
Electrical Service Inspection Pending
Misc
Corrective Action Required
10/29/2025
Ufer and bonding connections not installed correctly
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
10/29/2025
Both side -address separation wall sill plate in garage bearing and anchor bolts blowing out stem wall -address all walls not tied to separation walls -move all shower enclosures and wall studs to accommodate sheet rock at separation wall per design -insulate behind tub shower enclosures at exterior -trusses missing lateral bracing. (Started with A1, A2 and 3 missing bracing) check throughout 1204 -missing lib in garage -separation of all to extend to sheathing attic space above garage -seal top plate penetration W primary closet wall -remove tub/shower enclosure at separation wall for sheet rock -address open electrical at NE primary bedroom corner -plans do not call for header at rear primary to be continuous -seal top plate penetration at primary bedroom entry -provide strap per plan at rear slider -strap top plate where lapped less than 24” at foyer closet -address cut joist under primary bathroom 1206 -clip at separation wall near pfh missing screws -missing stud at garage owners entry -top plate penetration at laundry/primary closet -complete electrical at primary bedroom -provide strap and slider per plans
Footing Inspection - Residential Passed 8/6/2025 8/6/2025 08/06/2025
Underslab Plumbing Inspection - Residential Passed 8/12/2025 8/12/2025 08/12/2025
Sewer Service Inspection - R Passed 8/20/2025 8/20/2025 08/20/2025
Water Service Inspection - R Passed 8/21/2025 8/21/2025 08/21/2025
All Rough Inspection - Residential Partial 9/26/2025 9/26/2025 09/26/2025
Misc
Corrective Action Required
09/26/2025
Ok to cover portal frame
All Rough Inspection - Residential Not Ready 10/28/2025 10/28/2025 10/28/2025
Misc
Informational
10/28/2025
Ok to cover portal frame
Misc
Corrective Action Required
10/28/2025
Work still being performed. House not ready for inspection
Gas Service Inspection - Residential Failed 10/28/2025 10/28/2025 10/28/2025
Miscellaneous Correction
Corrective Action Required
10/28/2025
Trades still working. Inspection denied
Electrical Service Inspection Failed 10/28/2025 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/28/2025
Trades still working, inspection denied
Gas Service Inspection - Residential Failed 10/29/2025 10/29/2025 10/29/2025
Miscellaneous Correction
Resolved
10/29/2025
Trades still working. Inspection denied
Misc
Corrective Action Required
10/29/2025
No pressure at gauge
Electrical Service Inspection Failed 10/29/2025 10/29/2025 10/29/2025
Misc
Resolved
10/29/2025
Trades still working, inspection denied
Misc
Corrective Action Required
10/29/2025
Ufer and bonding connections not installed correctly
All Rough Inspection - Residential Failed 10/29/2025 10/29/2025 10/29/2025
Misc
Resolved
10/29/2025
Ok to cover portal frame
Misc
Resolved
10/29/2025
Work still being performed. House not ready for inspection
Misc
Corrective Action Required
10/29/2025
Both side -address separation wall sill plate in garage bearing and anchor bolts blowing out stem wall -address all walls not tied to separation walls -move all shower enclosures and wall studs to accommodate sheet rock at separation wall per design -insulate behind tub shower enclosures at exterior -trusses missing lateral bracing. (Started with A1, A2 and 3 missing bracing) check throughout 1204 -missing lib in garage -separation of all to extend to sheathing attic space above garage -seal top plate penetration W primary closet wall -remove tub/shower enclosure at separation wall for sheet rock -address open electrical at NE primary bedroom corner -plans do not call for header at rear primary to be continuous -seal top plate penetration at primary bedroom entry -provide strap per plan at rear slider -strap top plate where lapped less than 24” at foyer closet -address cut joist under primary bathroom 1206 -clip at separation wall near pfh missing screws -missing stud at garage owners entry -top plate penetration at laundry/primary closet -complete electrical at primary bedroom -provide strap and slider per plans
Documents & Images
Date Uploaded File Type Document Name
07/10/2025 BY #2320 - PERMIT APP
07/15/2025 Permit Codes Residential Plan Review
07/21/2025 Plot Plan APPROVED PLOT PLAN
07/21/2025 Approved Plans APPROVED TRUSS PACKAGE
07/21/2025 Approved Plans APPROVED TRUSS LAYOUT
07/21/2025 Approved Plans APPROVED PLANS
07/21/2025 Permit Codes Residential Plan Review
07/21/2025 Permit DS Building Permit
07/21/2025 Receipt Receipt for transaction:2025-005638
08/06/2025 1204 & 1206 SE Windbreak Dr Bailey Farms - FTNG - Stamped
08/06/2025 Letter INSPECTION SUMMARY
08/12/2025 Letter INSPECTION SUMMARY
08/20/2025 Letter INSPECTION SUMMARY
08/21/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/29/2025 Letter INSPECTION SUMMARY
10/29/2025 Letter INSPECTION SUMMARY
10/29/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home