Permit Application Status

PRRES20251843


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251843
Building Permit - Residential
Issued
WOODLAND OAKS LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK.
05/06/2025
06/05/2025
11/30/2025
Locations
Contacts
Stone Chase Homes,LLC, Address:30906 E stony point school rd , Phone:(816) 266-7395  
WOODLAND OAKS LLC, Address:656 BAYBERRY LN STE 101  
Brian shaw, Address:617 Sw Muriel Dr, Phone:(816) 266-7395  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MSSP LLC, Address:13544 BEGEMANN RD, Phone:(816) 365-7067  
BRIAN@STONECHASEPROPERTIES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 06/05/2025
Right of Way Permit Fee $85.00 $85.00 Paid 06/05/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/05/2025
Valuation Fee New Single Family $1,756.29 $1,756.29 Paid 06/05/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Water Service Inspection - R Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
11/19/2025
Install erosion control along the street and rear of lot
Driveway Inspection Pending
Misc
Informational
11/24/2025
11-21-25 NS Site visited and it appears that driveway has not started.
Erosion Control Inspection Residential Partial 7/11/2025 07/11/2025
Misc
Corrective Action Required
07/11/2025
Erosion control is in compliance
Footing Inspection - Residential Partial 7/11/2025 07/11/2025
Misc
Corrective Action Required
07/11/2025
Garage pads are not ready. OK to pour the rest of footing
Underslab Plumbing Inspection - Residential Passed 8/8/2025 8/8/2025 08/08/2025
Piers/Caissons Inspection - Residential Partial 8/8/2025 8/8/2025 08/08/2025
Misc
Informational
08/08/2025
2 piers in garage ok to pour
All Rough Inspection - Residential Failed 9/4/2025 9/4/2025 09/04/2025
Misc
Corrective Action Required
09/04/2025
Garage PFH wall nailing is OK; however, have engineer address braced wall requirement for rear exterior walls at master bedroom and dining room
Sewer Service Inspection - R Failed 11/3/2025 11/03/2025
Misc
Corrective Action Required
11/03/2025
Not ready
Sewer Service Inspection - R Passed 11/4/2025 11/4/2025 11/04/2025
Misc
Resolved
11/04/2025
Not ready
Gas Service Inspection - Residential Failed 11/19/2025 11/19/2025
Misc
Corrective Action Required
11/19/2025
No pressure
Electrical Service Inspection Failed 11/19/2025 11/19/2025
Misc
Corrective Action Required
11/19/2025
-The grounding clamp to ufer rebar shall be listed for aluminum conductor
Erosion Control Inspection Residential Failed 11/19/2025 11/19/2025
Misc
Corrective Action Required
07/11/2025
Install erosion control along the street and rear of lot
All Rough Inspection - Residential Failed 11/19/2025 11/19/2025 11/19/2025
Misc
Corrective Action Required
09/04/2025
Garage PFH wall nailing is OK; however, have engineer address braced wall requirement for rear exterior walls at master bedroom and dining room
Misc
Corrective Action Required
11/19/2025
-Garage pads were not ready at the footing inspection. Have engineer address -Provide intersystem bonding terminal block near service -Provide floodlight at rear of house -Provide siding and flashing above window at escape well -Garage PFH walls: install 2 anchors with 2”x2”x3/16” washer plates at garage sill plates per plan; install tension straps per plan -Fb all wall plate penetrations throughout -Securely fasten the SE cable within 12” of meter and panel -Remove all construction debris off the attic space -Complete garage plumbing fur out and fire block as required -Protect wiring running across ceiling joists within six ft of attic access with running boards -Support hip rafters above garage at ridge -Protect water lines at wall plates with BOCA strike plates -Install stud shoe at laundry wall stud bored more than 60% -Nail corner studs w/ 16d@12” oc or equivalent nailing -Nail rafters to ceiling joists and blockings to wall top plates per code -Install wall receptacle at rear dining wall -Have engineer address wall bracing for rear dining and master bedroom walls. More windows installed than shown on plan -Install blocking and fully nail all hanger holes at 14” lvl support at I beam -Install rigid gas piping at entry into the fireplace with flue through roof. Secure gas piping per code -Install insulation shield for fireplace flue in attic space -Fb walls at foyer and walkway from roof -Provide a wall receptacle for foyer wall more than 3 ft -Provide security blockings at master bedroom exterior door per security code; install door framing per security code -Securely fasten NM cable within 8” of rear patio receptacle box and front bedroom -Install stud shoe at master bathroom exterior wall stud bored more than 40% -Straps exterior top plates bored more than 50% -Fb floor penetrations at traps; fb wall plate holes at master water closet and shower -Support hip and valley rafters at ridges above hallway bathroom and master water closet -Seal penetrations of return air space -Support front porch beam after slab is poured -Nail one hanger at front bedroom near 3x beam -Toe nail joists to sill plates per code. Use 8d or 10d nails only -Bond gas piping **DO NOT INSULATE
Suspended Slab Inspection Passed 11/19/2025 11/19/2025
Misc
Informational
11/19/2025
Slab at front porch-OK
Footing Inspection - Residential Passed 11/19/2025
Misc
Resolved
11/19/2025
Garage pads are not ready. OK to pour the rest of footing
Piers/Caissons Inspection - Residential Passed 11/24/2025 11/24/2025 11/24/2025
Misc
Informational
08/08/2025
2 piers in garage ok to pour patio roof support piers
Driveway Inspection Partial 11/18/2025 11/24/2025
Misc
Informational
11/24/2025
11-21-25 NS Site visited and it appears that driveway has not started.
All Rough Inspection - Residential Failed 12/23/2025 12/23/2025 12/23/2025
Misc
Resolved
12/23/2025
Garage PFH wall nailing is OK; however, have engineer address braced wall requirement for rear exterior walls at master bedroom and dining room
Misc
Corrective Action Required
11/19/2025
-Garage PFH walls: install 2 anchors with 2”x2”x3/16” washer plates at garage sill plates per plan -Complete garage plumbing fur out and fire block as required **Fire block -Have engineer address wall bracing for rear dining and master bedroom walls. More windows installed than shown on plan **In master bedroom, install blockings and nail straps. OK to install 7/32” sheathing at dining wall -Fb walls at foyer, wall at stair, and wall at stair top landing from roof -Install stud shoe at master bathroom exterior wall stud bored more than 40% **Fully screw/nail the stud shoe at the back holes -Straps exterior top plates bored more than 50% **Also protect plumbing with BOCA plates for extra 2” protection beyond top plate -Bond gas piping **Use proper bonding clamp listed for aluminum conductor **OK TO INSULATE
Electrical Service Inspection Failed 12/23/2025 12/23/2025
Misc
Corrective Action Required
11/19/2025
-The grounding clamp to ufer rebar shall be listed for aluminum conductor
Gas Service Inspection - Residential Passed 12/23/2025 12/23/2025
Misc
Resolved
12/23/2025
No pressure
All Rough Inspection - Residential Passed 1/13/2026 1/13/2026 01/13/2026
Misc
Resolved
01/13/2026
-Have engineer address wall bracing for rear dining and master bedroom walls. More windows installed than shown on plan **In master bedroom, install blockings and nail straps. OK to install 7/32” sheathing at dining wall **OK TO ROCK. SEND PICTURE OF BLOCKINGS AND STRAPS
Electrical Service Inspection Failed 1/13/2026 01/13/2026
Misc
Corrective Action Required
12/23/2025
-The grounding clamp to ufer rebar shall be listed for aluminum conductor
Electrical Service Inspection Passed 2/25/2026 2/25/2026 02/25/2026
Misc
Resolved
02/25/2026
-The grounding clamp to ufer rebar shall be listed for aluminum conductor
Documents & Images
Date Uploaded File Type Document Name
05/20/2025 Permit Codes Residential Plan Review
05/23/2025 Plot Plan APPROVED PLOT PLAN
06/03/2025 Approved Plans APPROVED PLANS
06/03/2025 Letter Codes Residential Plan Review
06/04/2025 Application Form APPLICATION
06/04/2025 Permit Codes Residential Plan Review
06/05/2025 Permit DS Building Permit
06/05/2025 Receipt Receipt for transaction:2025-004179
07/11/2025 Letter INSPECTION SUMMARY
07/11/2025 Letter INSPECTION SUMMARY
08/08/2025 Letter INSPECTION SUMMARY
08/08/2025 Letter INSPECTION SUMMARY
09/04/2025 Letter INSPECTION SUMMARY
11/03/2025 Letter INSPECTION SUMMARY
11/04/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/24/2025 Letter INSPECTION SUMMARY
11/24/2025 Letter INSPECTION SUMMARY
12/22/2025 Engineer Report/Study 1809 NE Cherrybark Ct - Structural Letter (December 4, 2025)
12/23/2025 Letter INSPECTION SUMMARY
12/23/2025 Letter INSPECTION SUMMARY
12/23/2025 Letter INSPECTION SUMMARY
01/13/2026 Letter INSPECTION SUMMARY
01/13/2026 Letter INSPECTION SUMMARY
02/25/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home