Summary
PRRES20245123
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 11/12/2024 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 11/14/2024 12:00 AM by username 'Kyle Beard'.
09/26/2024
09/30/2024
08/29/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/30/2024
Right of Way Permit Fee $85.00 $85.00 Paid 09/30/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/30/2024
Water Tap Fee $3,973.00 $3,973.00 Paid 09/30/2024
Water Meter Fee $748.03 $748.03 Paid 09/30/2024
Valuation Fee New Single Family $1,464.19 $1,464.19 Paid 09/30/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 05/19/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 05/19/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 06/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 07/18/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 11/12/2024 11/12/2024 11/12/2024
Footing Inspection - Residential Failed - Stop Work 11/12/2024 11/12/2024
Misc
Corrective Action Required
11/12/2024
STOP WORK NO FOOTING INSPECTION ON FILE
Footing Inspection - Residential Failed 11/14/2024 11/14/2024 11/14/2024
Misc
Corrective Action Required
11/12/2024
STOP WORK NO FOOTING INSPECTION ON FILE 2nd request for footing inspection to be uploaded to portal Replace moved erosion control measures 11/14/24. KBEARD
Footing Inspection - Residential Passed 11/14/2024 11/14/2024
Misc
Resolved
11/14/2024
STOP WORK NO FOOTING INSPECTION ON FILE 2nd request for footing inspection to be uploaded to portal Replace moved erosion control measures 11/14/24. KBEARD
Miscellaneous Correction
Informational
11/14/2024
Footing was passed by a third party Exterior piers were not mentioned in the footing reported
Water Service Inspection - R Partial 11/19/2024 11/19/2024 11/19/2024
Misc
Corrective Action Required
11/19/2024
PARTIAL POLY OUT OF FOUNDATION 20' AND 10' COPPER
Water Service Inspection - R Passed 11/19/2024 11/19/2024 11/19/2024
Misc
Resolved
11/19/2024
PARTIAL POLY OUT OF FOUNDATION 20' AND 10' COPPER
Underslab Plumbing Inspection - Residential Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Corrective Action Required
12/06/2024
Inspection denied erosion control, not in compliance
Erosion Control Inspection Residential Failed 12/6/2024 12/6/2024 12/06/2024
DCM5 ESC INSP DENIED
Corrective Action Required
12/06/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/06/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Failed 12/12/2024 12/12/2024 12/12/2024
Misc
Resolved
12/12/2024
Inspection denied erosion control, not in compliance
Misc
Corrective Action Required
12/12/2024
Connect drain tile throughout
Underslab Plumbing Inspection - Residential Not Ready 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/12/2024
Connect drain tile throughout Not done
Underslab Plumbing Inspection - Residential Passed 12/18/2024 12/18/2024 12/18/2024
Misc
Resolved
12/18/2024
Connect drain tile throughout Not done
Piers/Caissons Inspection - Residential Passed 2/27/2025 2/27/2025 02/27/2025
Electrical Service Inspection Failed 3/3/2025 3/3/2025 03/03/2025
Misc
Corrective Action Required
03/03/2025
Requested inspection denied due to lack of erosion control.
Gas Service Inspection - Residential Failed 3/3/2025 3/3/2025 03/03/2025
Misc
Corrective Action Required
03/03/2025
Requested inspection denied due to lack of erosion control.
All Rough Inspection - Residential Failed 3/3/2025 3/3/2025 03/03/2025
Misc
Corrective Action Required
03/03/2025
Requested inspection denied due to lack of erosion control.
Erosion Control Inspection Residential Failed 3/3/2025 3/3/2025 03/03/2025
DCM5 ESC INSP DENIED
Corrective Action Required
12/06/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/03/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 3/4/2025 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
Requested inspection denied due to lack of erosion control.
Misc
Corrective Action Required
03/04/2025
-missing truss bracing multiple places A13, A14, etc. -primary bedroom missing truss hold downs at bearing points in dining areas, primary bedroom, -missing lib bracing at foyer -seal penetrations at foyer bath entry -provide stud shoes at braced where board for dwv in laundry -sister all notched studs in basement full length where notched for anchor bolts. -fire blocking in basement needs to comply with code section 302.11.1 of the 2018 irc. (Cannot use (2)1/2” plywood) -fireblock furr down ends in basement bedroom 1 -fireblock basement bath walls into furr downs -fire block bed 2 into furr down -fire block under primary tub in bed 2 closet. -provide blocking under kitchen island -
Electrical Service Inspection Passed 3/4/2025 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
Requested inspection denied due to lack of erosion control.
Gas Service Inspection - Residential Passed 3/4/2025 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
Requested inspection denied due to lack of erosion control.
All Rough Inspection - Residential Failed 3/14/2025 3/14/2025 03/14/2025
Misc
Corrective Action Required
03/04/2025
-primary bedroom missing truss hold downs at bearing points in dining areas, primary bedroom, -provide stud shoes at braced where board for dwv in laundry -provide protection for dryer vent at top plate -sister all notched studs in basement full length where notched for anchor bolts. -fire blocking in basement needs to comply with code section 302.11.1 of the 2018 irc. (Cannot use (2)1/2” plywood)(complete where moved)
All Rough Inspection - Residential Passed 3/20/2025 3/20/2025 03/20/2025
Misc
Resolved
03/20/2025
-primary bedroom missing truss hold downs at bearing points in dining areas, primary bedroom, -provide stud shoes at braced where board for dwv in laundry -provide protection for dryer vent at top plate -sister all notched studs in basement full length where notched for anchor bolts. -fire blocking in basement needs to comply with code section 302.11.1 of the 2018 irc. (Cannot use (2)1/2” plywood)(complete where moved)
Driveway Inspection Partial 4/22/2025 4/22/2025 04/22/2025
Misc
Informational
04/22/2025
4-22-25 Dustin A, DW is formed to city specs. approved to pour.
Driveway Inspection Partial 5/5/2025 5/5/2025 05/05/2025
Misc
Informational
04/22/2025
4-22-25 Dustin A, DW is formed to city specs. approved to pour. 05-05-25 Jamie S, DW is in compliance with city standards.
Occupancy Inspection - Codes Residential Failed 5/13/2025 5/13/2025 05/13/2025
Misc
Corrective Action Required
05/13/2025
1531 SW Arbor Valley - grade yard and sod, install splash blocks, install sump drainage 36” from foundation - Seal all exterior penetrations - Install soffit vents - Pour landing for deck steps - Obtain final driveway inspection - Address issue with water meter pit full of water - Bottom bracket on large garage door must be within 18” of floor joists - Deck handrail must be graspable as per code - Secure main water line to wall in basement - Cut off excess rebar at main water line entrance - Cut off excess rebar at ufer ground -
Occupancy Inspection - Codes Residential Failed 5/15/2025 5/15/2025 05/15/2025
Misc
Corrective Action Required
05/13/2025
1531 SW Arbor Valley - grade yard and sod, install splash blocks, install sump drainage 36” from foundation - Seal all exterior penetrations - Install soffit vents - Obtain final driveway inspection - Address issue with water meter pit full of water - Bottom bracket on large garage door must be within 18” - Secure main water line to wall in basement - Cut off excess rebar at main water line entrance - Cut off excess rebar at ufer ground -
Occupancy Inspection - Codes Residential Ready for Temp CO 5/19/2025 5/19/2025 05/19/2025
Misc
Corrective Action Required
05/15/2025
1531 SW Arbor Valley - grade yard and sod, install splash blocks, install sump drainage 36” from foundation - Seal all exterior penetrations - Install soffit vents - Obtain final driveway inspection - Address issue with water meter pit full of water -
Occupancy Inspection - Codes Residential Ready for Temp CO 6/18/2025 06/18/2025
Misc
Corrective Action Required
05/19/2025
1531 SW Arbor Valley - grade yard and sod, install splash blocks, install sump drainage 36” from foundation - Seal all exterior penetrations - Install soffit vents - Obtain final driveway inspection - Address issue with water meter pit full of water -
Occupancy Inspection - Codes Residential Ready for Temp CO 7/18/2025 07/18/2025
Misc
Corrective Action Required
06/18/2025
1531 SW Arbor Valley - grade yard and sod, install splash blocks, install sump drainage 36” from foundation - Seal all exterior penetrations - Install soffit vents - Obtain final driveway inspection - Address issue with water meter pit full of water -
Plot Plan Inspection Passed 8/7/2025 08/07/2025
Occupancy Inspection - Codes Residential Failed 8/21/2025 8/21/2025 08/21/2025
Misc
Corrective Action Required
07/18/2025
1531 SW Arbor Valley - Obtain final driveway inspection
Driveway Inspection Passed 8/22/2025 8/22/2025 08/22/2025
Misc
Informational
05/05/2025
4-22-25 Dustin A, DW is formed to city specs. approved to pour. 05-05-25 Jamie S, DW is in compliance with city standards.
Erosion Control Inspection Residential Passed 8/29/2025 08/29/2025
DCM5 ESC INSP DENIED
Resolved
08/29/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Resolved
08/29/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 8/29/2025 8/29/2025 08/29/2025
Misc
Resolved
08/29/2025
1531 SW Arbor Valley - Obtain final driveway inspection
Documents & Images
Date Uploaded File Type Document Name
09/26/2024 HT #82 - PERMIT APP
09/30/2024 Approved Plans APPROVED PLANS
09/30/2024 Plot Plan APPROVED PLOT PLAN
09/30/2024 Approved Plans APPROVED TRUSS LAYOUT
09/30/2024 Approved Plans APPROVED TRUSS PACKAGE
09/30/2024 Permit Codes Residential Plan Review
09/30/2024 Permit DS Building Permit
09/30/2024 Receipt Receipt for transaction:2024-008003
11/02/2024 M L Crose 1531 SW Arbor Valley Dr, LSMO 3rd Party Footing Inspection Report 10-31-24
11/12/2024 Letter Stop Work Order
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 M L Crose 1531 SW Arbor Valley Dr, LSMO 3rd Party Footing Inspection Report 10-31-24
11/14/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
01/07/2025 Approved Plans APPROVED TRUSS PACKAGE
02/27/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/07/2025 Approved Plans APPROVED REVISED PLANS
03/14/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/13/2025 Letter INSPECTION SUMMARY
05/15/2025 Letter INSPECTION SUMMARY
05/19/2025 Letter INSPECTION SUMMARY
05/19/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/19/2025 Receipt Receipt for transaction:2025-003506
06/09/2025 HT #82 - TCOExtension Submitall - 6_9_25
06/18/2025 Letter INSPECTION SUMMARY
06/18/2025 Certificate/License Codes Temporary Certificate of Occupancy
06/18/2025 Receipt Receipt for transaction:2025-004634
07/09/2025 Application Form TCOExtension
07/18/2025 Letter INSPECTION SUMMARY
07/18/2025 Certificate/License Codes Temporary Certificate of Occupancy
07/18/2025 Receipt Receipt for transaction:2025-005590
08/05/2025 LOT 82 ASBUILT
08/06/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
08/07/2025 Letter INSPECTION SUMMARY
08/07/2025 HT #82 - TCO Extension 8_7_25
08/21/2025 Letter INSPECTION SUMMARY
08/22/2025 Letter INSPECTION SUMMARY
08/29/2025 Letter Codes Final Certificate of Occupancy
08/29/2025 Letter Field Certificate of Occupancy
08/29/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home