Summary
PRRES20244614
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNCOVERED DECK - UNFINISHED BASEMENT -
08/28/2024
09/09/2024
03/02/2025
05/16/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/09/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/09/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/09/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 09/09/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 09/09/2024
9110078-Valuation Fee New Single Family $1,200.46 $1,200.46 Paid 09/09/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 01/06/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/9/2024 10/08/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/08/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Straw waddle at the street is in the street instead of being installed No gravel on site or in the lot between the foundation and the street
Footing Inspection - Residential Passed 10/9/2024 10/08/2024
Miscellaneous Correction
Informational
10/08/2024
Footing was passed by a third party. Piers were not present in the footing report. Full erosion control measures were not in place at the time of third party footing inspection because gravel is not on site or between the foundation and the street.
Sewer Service Inspection - R Passed 10/16/2024 10/16/2024 10/16/2024
Erosion Control Inspection Residential Failed 10/17/2024 10/17/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/08/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Straw waddle at the street is in the street instead of being installed No gravel on site or in the lot between the foundation and the street Second notice
Water Service Inspection - R Passed 10/17/2024 10/17/2024 10/17/2024
Erosion Control Inspection Residential Partial 10/23/2024 10/23/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/23/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Straw waddle at the street is in the street instead of being installed No gravel on site or in the lot between the foundation and the street Second notice
Miscellaneous Correction
Informational
10/23/2024
Full erosion control measures are in place and must be properly maintained until CofO
Underslab Plumbing Inspection - Residential Passed 10/23/2024 10/23/2024 10/23/2024
Erosion Control Inspection Residential Partial 11/5/2024 11/05/2024
Miscellaneous Correction
Informational
10/23/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Failed 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/09/2024
Portal frame and front porch roof missing inspection only Approved
Erosion Control Inspection Residential Partial 12/17/2024 12/17/2024
Miscellaneous Correction
Informational
11/05/2024
Full erosion control measures are in place and must be properly maintained until CofO
Gas Service Inspection - Residential Passed 12/17/2024 12/17/2024 12/17/2024
Electrical Service Inspection Failed 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/17/2024
-Shall connect one conductor per grounding clamp. Connection to rebar grounding clamp is not compliant with product design/listing
All Rough Inspection - Residential Failed 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/09/2024
-Nail exterior wall siding along edges @ 6” oc -Fb garage plumbing space from joist space -Provide R-19 thermal envelope at garage ceiling -Tighten all anchor nuts -Complete soffit or ceiling fur down at half bathroom and fb wall per code; lower ducting to ceiling level; secure electrical wiring at max 4.5 ft -Fb rec room wall from soffit -Solid block cantilevered joists to top plates; FYI: deck joists to bear on the top plates. See plan notes -Provide water service shutoff within 5 ft of building entrance -Install entry door frame -Provide a listed floor box at guardrail -Install flashing at plumbing penetration of roof above master bedroom -Strap exterior wall top plates where bored more than 50% -Fb floor at space adjacent to master bathroom shower **DO NOT INSULATE
Electrical Service Inspection Passed 12/23/2024 12/23/2024 12/23/2024
Misc
Resolved
12/23/2024
-Shall connect one conductor per grounding clamp. Connection to rebar grounding clamp is not compliant with product design/listing
All Rough Inspection - Residential Failed 12/23/2024 12/23/2024 12/23/2024
Misc
Corrective Action Required
12/17/2024
-Fb rec room wall from soffit -Provide water service shutoff within 5 ft of building entrance -Strap exterior wall top plates where bored more than 50% OK TO INSULATE
Erosion Control Inspection Residential Partial 12/27/2024 12/27/2024
Miscellaneous Correction
Informational
12/17/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Failed 12/27/2024 12/27/2024 12/27/2024
Misc
Resolved
12/27/2024
-Fb rec room wall from soffit -Provide water service shutoff within 5 ft of building entrance -Strap exterior wall top plates where bored more than 50% OK TO INSULATE
Miscellaneous Correction
Corrective Action Required
12/27/2024
Fb rec room wall from soffit around Ibeam -Strap exterior wall top plates where bored more than 50% (in master bathroom) OK TO INSULATE
Erosion Control Inspection Residential Partial 12/30/2024 12/30/2024
Miscellaneous Correction
Informational
12/27/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Failed 12/30/2024 12/30/2024 12/30/2024
Miscellaneous Correction
Corrective Action Required
12/27/2024
Fb rec room wall from soffit around Ibeam -Strap exterior wall top plates where bored more than 50% (in master bathroom) OK TO INSULATE
Miscellaneous Correction
Corrective Action Required
12/30/2024
Fb rec room wall from soffit around Ibeam OK TO INSULATE
All Rough Inspection - Residential Passed 1/2/2025 1/2/2025 01/02/2025
Miscellaneous Correction
Resolved
01/02/2025
Fb rec room wall from soffit around Ibeam -Strap exterior wall top plates where bored more than 50% (in master bathroom) OK TO INSULATE
Miscellaneous Correction
Resolved
01/02/2025
Fb rec room wall from soffit around Ibeam OK TO INSULATE
Erosion Control Inspection Residential Partial 1/27/2025 01/27/2025
Miscellaneous Correction
Informational
12/30/2024
Full erosion control measures are in place and must be properly maintained until CofO
Piers/Caissons Inspection - Residential Passed 2/10/2025 2/10/2025 02/10/2025
Sidewalk Inspection Partial 2/26/2025 2/26/2025 02/26/2025
Misc
Informational
02/26/2025
02/26/2025 - Jamie S, SW is compacted, and forms are sloped to city standards, North panel will be out of compliance for storm manhole, approved to pour
Driveway Inspection Partial 2/26/2025 2/26/2025 02/26/2025
Misc
Informational
02/26/2025
02/26/2025 - Jamie S, DW is compacted approved to pour
Occupancy Inspection - Codes Residential Failed 3/3/2025 3/3/2025 03/03/2025
Miscellaneous Correction
Corrective Action Required
03/03/2025
-Front porch has a height of over 30 inches and requires hand and guard rails to be installed -Garage to house self closing door will not fully latch -Hatch under basement stairs is not sealed -Bottom step going to the basement has a riser height of 8 3/4 inches and is out of code compliance -First step riser in main entrance going up has a height of 8 1/2 inches -Seal top of electrical meter -Seal top of extras lights -Sod, splash pads and sump pump extension are not installed -Driveway and sidewalk final inspections are not completed -Plot plan could not be completed because of final grading not being completed
Driveway Inspection Passed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/26/2025
02/26/2025 - Jamie S, DW is compacted approved to pour 03-06-25 Jamie S, DW slope is within city standards.
Sidewalk Inspection Failed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/26/2025
02/26/2025 - Jamie S, SW is compacted, and forms are sloped to city standards, North panel will be out of compliance for storm manhole, approved to pour 03-06-25 Jamie S, SW panel north of DW with storm manhole inside of the panel needs to be replaced due to no expansion joint around storm manhole. Expansion joint need to be installed on both sides to existing sidewalk. Will have to call in for reinspection.
Occupancy Inspection - Codes Residential Failed 3/10/2025 3/10/2025 03/10/2025
Miscellaneous Correction
Corrective Action Required
03/03/2025
**Coulter requested call ahead but the phone number given (816-789-9711) is not set up for messages -Hatch under basement stairs is not sealed **Accessible and enclosed space underneath the stair shall have wall and ceiling protected with 1/2” gypsum -Sod, splash pads and sump pump extension are not installed -Sidewalk final inspections are not completed -Plot plan could not be completed because of final grading not being completed **Complete final grading and submit as-graded plot plan for inspection prior to sodding -Reset water meter top&lid
Sidewalk Inspection Partial 3/11/2025 3/11/2025 03/11/2025
Misc
Informational
03/06/2025
02/26/2025 - Jamie S, SW is compacted, and forms are sloped to city standards, North panel will be out of compliance for storm manhole, approved to pour 03-06-25 Jamie S, SW panel north of DW with storm manhole inside of the panel needs to be replaced due to no expansion joint around storm manhole. Expansion joint need to be installed on both sides to existing sidewalk. Will have to call in for reinspection. 3-11-25 DP. SW panel was pulled, expansion added around MH. Cross slopes in compliances, made mention to leave out a tripping hazzard. Approved to pour.
Sidewalk Inspection Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Informational
03/11/2025
02/26/2025 - Jamie S, SW is compacted, and forms are sloped to city standards, North panel will be out of compliance for storm manhole, approved to pour 03-06-25 Jamie S, SW panel north of DW with storm manhole inside of the panel needs to be replaced due to no expansion joint around storm manhole. Expansion joint need to be installed on both sides to existing sidewalk. Will have to call in for reinspection. 3-11-25 DP. SW panel was pulled, expansion added around MH. Cross slopes in compliances, made mention to leave out a tripping hazzard. Approved to pour. 3-12-25 DP. SW was poured, forms have been removed. Please clear off sidewalk and remove caution tape. Passed.
Occupancy Inspection - Codes Residential Ready for Temp CO 3/13/2025 3/13/2025 03/13/2025
Miscellaneous Correction
Corrective Action Required
03/10/2025
-Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed because of final grading not being completed **Complete final grading and submit as-graded plot plan for inspection prior to sodd - Land sewer trace wire to grade
Erosion Control Inspection Residential Passed 05/16/2025
Miscellaneous Correction
Informational
01/27/2025
Full erosion control measures are in place and must be properly maintained until CofO
Plot Plan Inspection Passed 5/16/2025 5/16/2025 05/16/2025
Occupancy Inspection - Codes Residential Full C of O 5/16/2025 5/16/2025 05/16/2025
Miscellaneous Correction
Resolved
05/16/2025
-Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed because of final grading not being completed **Complete final grading and submit as-graded plot plan for inspection prior to sodd - Land sewer trace wire to grade
Documents & Images
Date Uploaded File Type Document Name
09/03/2024 Permit Codes Residential Plan Review
09/05/2024 Plot Plan APPROVED PLOT PLAN
09/09/2024 CB #11 - PERMIT APP
09/09/2024 Approved Plans APPROVED PLANS
09/09/2024 Approved Plans APPROVED TRUSS LAYOUT
09/09/2024 Approved Plans APPROVED TRUSS PACKAGE
09/09/2024 Permit Codes Residential Plan Review
09/09/2024 Permit DS Building Permit
09/09/2024 Receipt Receipt for transaction:2024-007537
10/08/2024 M L Crose 3437 SE Corbin Dr LSMO Cobey Creek Lot 11 Clayton Permit 2024-4614 Footing Inspection Report 10-7-24
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/06/2025 Receipt Receipt for transaction:2025-000050
01/27/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001533
03/26/2025 LOT 11 ASBUILT
03/27/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter Codes Final Certificate of Occupancy
05/16/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home