Summary
PRRES20243549
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT.
07/11/2024
07/29/2024
01/12/2025
04/15/2025
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
TRUMARK HOMES LLC, Address:2924 NW THOREAU DR  
MARK A YANCIK, Address:508 nw manor dr  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
TRUMARKHOMES.KYLE@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 07/29/2024
Water Meter Fee $748.03 $748.03 Paid 07/29/2024
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 07/29/2024
Right of Way Permit Fee $85.00 $85.00 Paid 07/29/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/29/2024
Valuation Fee New Single Family $1,328.48 $1,328.48 Paid 07/29/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/05/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 04/14/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Partial 1/28/2025 1/28/2025 08/16/2024
Misc
Informational
08/16/2024
8-16-24 NS Do not forget to make sure water valve is uncovered.
Erosion Control Inspection Residential Failed 8/19/2024 08/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/19/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 8/19/2024 8/19/2024 08/19/2024
Misc
Corrective Action Required
08/19/2024
-Submit footing inspetion report to city. No further inspection until footing inspection report is submitted -Correct erosion control
Footing Inspection - Residential Passed 10/04/2024
Informational
10/04/2024
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Passed 10/04/2024
Misc
Resolved
10/04/2024
-Submit footing inspetion report to city. No further inspection until footing inspection report is submitted -Correct erosion control
Erosion Control Inspection Residential Failed 10/4/2024 10/04/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/19/2024
DEFICIENT EROSION CONTROL INSTALLATION. REPAIR EROSION CONTROL NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Passed 10/4/2024 10/04/2024
Gas Service Inspection - Residential Failed 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/04/2024
Not ready
All Rough Inspection - Residential Failed 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/04/2024
-Nail siding and sheathing per code-along edges @ 6” oc and 12” oc in field -Nail garage PFH wall sheathing per code -Complete garage walkout door; install security blockings -Nail corner studs 16d@12” oc or equivalent nailing -Fb wall plate penetrations throughout -Install stud shoe for over bored 3x stud pack in bathroom -Provide hanger support for rafters above master bathroom shower -Strap wall top plates lapped less than 24” at master closet -Fasten fireplace to framing -Complete gas piping -Face-nail rafter to ceiling joist with 3-10d nails -Support hip rafters above front bedroom; install beam to support all hip rafters off the non-bearing wall -Install front entry door frame per security code -Fb floor at tub trap -Toe nail joists to sill plates (4)8d or (3)10d -Column near basement bathroom not at right location -Solid block underneath 18” lvl point load **DO NOT INSULATE
Sewer Service Inspection - R Passed 10/4/2024 10/4/2024 10/04/2024
Erosion Control Inspection Residential Failed 10/7/2024 10/07/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/04/2024
DEFICIENT EROSION CONTROL INSTALLATION. REPAIR EROSION CONTROL NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Water Service Inspection - R Passed 10/7/2024 10/7/2024 10/07/2024
Erosion Control Inspection Residential Partial 10/9/2024 10/09/2024
Misc
Informational
10/09/2024
EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 10/9/2024 10/9/2024 10/09/2024
Misc
Corrective Action Required
10/04/2024
-Nail siding and sheathing per code-along edges @ 6” oc and 12” oc in field -Strap garage PFH wall lvl beam per code. Extend strap to wall top plates -Complete garage walkout door; install security blockings -Fb wall plate penetrations throughout -Support hip rafters above front bedroom; install beam to support all hip rafters off the non-bearing wall -Install front entry door frame per security code **Shim gap at hinges -Fb floor at tub trap -Toe nail joists to sill plates (4)8d or (3)10d **DO NOT INSULATE FLOOR RIM IN BASEMENT
Gas Service Inspection - Residential Passed 10/9/2024 10/9/2024 10/09/2024
Misc
Resolved
10/09/2024
Not ready
All Rough Inspection - Residential Failed 10/10/2024 10/10/2024 10/10/2024
Misc
Corrective Action Required
10/09/2024
-Complete garage walkout door **Also install trim and flashing above -Support hip and ridge to beam or bearing wall
All Rough Inspection - Residential Partial 10/14/2024 10/14/2024 10/14/2024
Misc
Corrective Action Required
10/10/2024
-Complete garage walkout door **Also install trim and flashing above
Erosion Control Inspection Residential Partial 10/29/2024 10/29/2024
Misc
Informational
10/09/2024
EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Piers/Caissons Inspection - Residential Passed 10/29/2024 10/29/2024
Informational
10/29/2024
2-18' PIERS FOR FUTURE USE ON PATIO
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Misc
Corrective Action Required
11/01/2024
Restore erosion control along street and clean mud off the street. No further inspection if erosion control is not in compliance
Driveway Inspection Passed 01/30/2025
Misc
Informational
08/16/2024
8-16-24 NS Do not forget to make sure water valve is uncovered. 1-28-25 NS Site visited for a pre-pour inspection and it appears that driveway meets city standards 1-30-25 NS Site visited and it appears that driveway has been poured and it I talked to the Forman and the house is closing on 1-31 Friday and Michel said he would have the forms removed on Monday 2-3-25 but I am going to pass this inspection so they can close on the house.
Erosion Control Inspection Residential Partial 2/4/2025 02/04/2025
Misc
Corrective Action Required
11/01/2024
Erosion control in compliance
All Rough Inspection - Residential Passed 02/04/2025
Misc
Resolved
02/04/2025
-Complete garage walkout door **Also install trim and flashing above
Occupancy Inspection - Codes Residential Failed 2/4/2025 2/4/2025 02/04/2025
Misc
Corrective Action Required
02/04/2025
-Provide landscaping as required per plot plan -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Garage door not self-closing -Provide graspable handrail for garage stair -Screw the exterior garage door embedded jamb brace into studs -Fasten window well ladder in place -Label/identify all dedicated non-gfci receptacles in basement -Provide max 30 amp AC breaker
Occupancy Inspection - Codes Residential Ready for Temp CO 2/6/2025 2/6/2025 02/06/2025
Misc
Corrective Action Required
02/04/2025
-Provide landscaping as required per plot plan -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Screw the exterior garage door embedded jamb brace into studs through the four pre-drilled holes with min 3" screws
Erosion Control Inspection Residential Passed 04/04/2025
Misc
Resolved
04/04/2025
Erosion control in compliance
Occupancy Inspection - Codes Residential Failed 4/4/2025 04/04/2025
Misc
Corrective Action Required
02/06/2025
-Provide landscaping as required per plot plan -Screw the exterior garage door embedded jamb brace into studs through the four pre-drilled holes with min 3" screws **TCO was issued on Feb-6. TCO is currently expire and must be extended or will be NOV status. All due fees (2 TCO fees) must be paid
Occupancy Inspection - Codes Residential Ready for Temp CO 4/14/2025 04/14/2025
Misc
Corrective Action Required
04/04/2025
-Provide landscaping as required per plot plan -Screw the exterior garage door embedded jamb brace into studs through the four pre-drilled holes with min 3" screws **TCO was issued on Feb-6. TCO is currently expire and must be extended or will be NOV status. All due fees (2 TCO fees) must be paid
Occupancy Inspection - Codes Residential Full C of O 4/15/2025 4/15/2025 04/15/2025
Misc
Resolved
04/15/2025
-Provide landscaping as required per plot plan -Screw the exterior garage door embedded jamb brace into studs through the four pre-drilled holes with min 3" screws **TCO was issued on Feb-6. TCO is currently expire and must be extended or will be NOV status. All due fees (2 TCO fees) must be paid
Documents & Images
Date Uploaded File Type Document Name
07/11/2024 MONTICELLO LOT 70 APPLICATION PERMIT
07/15/2024 Permit Codes Residential Plan Review
07/16/2024 Plot Plan APPROVED PLOT PLAN
07/16/2024 Permit Codes Residential Plan Review
07/19/2024 Approved Plans APPROVED PLANS
07/19/2024 Permit Codes Residential Plan Review
07/29/2024 Permit DS Building Permit
07/29/2024 Receipt Receipt for transaction:2024-006297
08/16/2024 Letter INSPECTION SUMMARY
09/04/2024 monticello lot 70 footing insp_
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/06/2025 Letter INSPECTION SUMMARY
03/05/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/05/2025 Receipt Receipt for transaction:2025-001298
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/14/2025 Application Form TCO EXTENSION
04/14/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/14/2025 Receipt Receipt for transaction:2025-002280
04/15/2025 Letter Codes Final Certificate of Occupancy
04/15/2025 Letter Field Certificate of Occupancy
04/15/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents