Permit Application Status

PRRES20243479


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243479
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
07/08/2024
07/25/2024
01/21/2025
04/10/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 07/25/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/25/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/25/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 07/25/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 07/25/2024
9110078-Valuation Fee New Single Family $1,735.26 $1,735.26 Paid 07/25/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 8/13/2024 08/13/2024
Footing Inspection - Residential Partial 8/13/2024 08/13/2024
Footing Inspection - Residential Passed 8/13/2024 08/13/2024
Underslab Plumbing Inspection - Residential Passed 8/15/2024 8/15/2024 08/15/2024
Sewer Service Inspection - R Passed 8/19/2024 08/19/2024
Water Service Inspection - R Partial 8/19/2024 08/19/2024
Misc
Corrective Action Required
08/19/2024
Pex ran from house
Water Service Inspection - R Passed 8/20/2024 08/20/2024
Misc
Resolved
08/20/2024
Pex ran from house
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 10/17/2024 10/17/2024 10/17/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, corrected
Electrical Service Inspection Passed 11/4/2024 11/4/2024 11/04/2024
Gas Service Inspection - Residential Failed 11/4/2024 11/4/2024 11/04/2024
Misc
Corrective Action Required
11/04/2024
Address gas line issues stated in all rough inspection report for inspection
All Rough Inspection - Residential Failed 11/4/2024 11/4/2024 11/04/2024
Misc
Corrective Action Required
11/04/2024
-nail all exterior doors all corners together to plans -provide Boca plate protection for dwv at rear 3rd car garage sill plate -seal top plate penetration at rear 3rd car garage -address roof support landing in non load bearing wall at mud room -secure gas line at fireplace -fireblock wall space to ceiling space above pantry and radon plumbing -address wall framing in laundry (6 top plates landing on top of ceiling joists ) -provide hangers for for triple 2x12 above master bath -seal top plate penetration N master bedroom wall -tighten all anchor bolts in basement -strap top plate at top plate at basement slider both sides -seal penetrations in R/a joist space above bed 4 -remove gas line from R/a joist space above bed 4 -when using unfaced insulation for fire blocking it must be packed tightly and securely -seal penetrations in R/a joist space above basement bath -seal dead space at bed 4 bath -seal penetrations in bed 4 closet wall space into furr down
All Rough Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Misc
Resolved
11/07/2024
-nail all exterior doors all corners together to plans -provide Boca plate protection for dwv at rear 3rd car garage sill plate -seal top plate penetration at rear 3rd car garage -address roof support landing in non load bearing wall at mud room -secure gas line at fireplace -fireblock wall space to ceiling space above pantry and radon plumbing -address wall framing in laundry (6 top plates landing on top of ceiling joists ) -provide hangers for for triple 2x12 above master bath -seal top plate penetration N master bedroom wall -tighten all anchor bolts in basement -strap top plate at top plate at basement slider both sides -seal penetrations in R/a joist space above bed 4 -remove gas line from R/a joist space above bed 4 -when using unfaced insulation for fire blocking it must be packed tightly and securely -seal penetrations in R/a joist space above basement bath -seal dead space at bed 4 bath -seal penetrations in bed 4 closet wall space into furr down
Misc
Corrective Action Required
11/07/2024
-seal penetrations in R/a joist space above basement bath and hall
Gas Service Inspection - Residential Passed 11/7/2024 11/7/2024 11/07/2024
Misc
Resolved
11/07/2024
Address gas line issues stated in all rough inspection report for inspection
All Rough Inspection - Residential Passed 11/8/2024 11/8/2024 11/08/2024
Misc
Resolved
11/08/2024
-seal penetrations in R/a joist space above basement bath and hall
Driveway Inspection Partial 12/31/2024 12/31/2024 12/31/2024
Misc
Informational
12/31/2024
12-31-24 Jamie S, Dw is formed and compacted. Approved to pour.
Sidewalk Inspection Partial 1/2/2025 1/2/2025 01/02/2025
Misc
Informational
01/02/2025
01-02-25 Jamie S, SW has been formed and compacted. Gravel on either side was not deep enough to connect to existing sidewalk. Talked to contractor and approved to pour contingent upon fixing the depth of gravel.
Erosion Control Inspection Residential Failed 3/7/2025 03/07/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
03/07/2025
10-14-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, corrected
DCM5 ESC INSP DENIED
Corrective Action Required
03/07/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Failed 3/7/2025 3/7/2025 03/07/2025
Misc
Corrective Action Required
03/07/2025
Inspection denied no erosion control
Occupancy Inspection - Codes Residential Failed 3/11/2025 3/11/2025 03/11/2025
Misc
Resolved
03/11/2025
Inspection denied no erosion control
Misc
Corrective Action Required
03/11/2025
-address pending driveway and sidewalk inspection -provide as graded plot plan -Final grade and sod -splash blocks and sump pump discharge to extend 3
Driveway Inspection Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Informational
12/31/2024
12-31-24 Jamie S, Dw is formed and compacted. Approved to pour. 3-12-25 DP. DW was poured, forms have been removed, cross slopes are in compliance. Passed
Sidewalk Inspection Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Informational
01/02/2025
01-02-25 Jamie S, SW has been formed and compacted. Gravel on either side was not deep enough to connect to existing sidewalk. Talked to contractor and approved to pour contingent upon fixing the depth of gravel. 3-12-25 DP. SW was poured, forms have been removed, cross slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Ready for Temp CO 3/13/2025 3/13/2025 03/13/2025
Misc
Resolved
03/13/2025
-address pending driveway and sidewalk inspection -provide as graded plot plan -Final grade and sod -splash blocks and sump pump discharge to extend 3
Plot Plan Inspection Passed 4/1/2025 04/01/2025
Erosion Control Inspection Residential Passed 04/10/2025
DCM5 ESC INSP DENIED
Resolved
04/10/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Full C of O 4/10/2025 4/10/2025 04/10/2025
Documents & Images
Date Uploaded File Type Document Name
07/10/2024 Permit Codes Residential Plan Review
07/10/2024 Approved Plans APPROVED PLANS
07/25/2024 Plot Plan APPROVED PLOT PLAN
07/25/2024 Permit Codes Residential Plan Review
07/25/2024 LS Permit Revised Application 2817 Heartland
07/25/2024 Permit Codes Residential Plan Review
07/25/2024 Permit DS Building Permit
07/25/2024 Receipt Receipt for transaction:2024-006233
08/12/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
08/12/2024 Engineer Report/Study ENGINEER SOIL LETTER
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/05/2024 Engineer Report/Study 2817 SW Heartland Rd - Inspection Letter (November 4, 2024)
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
12/31/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001563
03/28/2025 LOT 182 ASBUILT
03/31/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
04/01/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter Field Certificate of Occupancy
04/10/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home