Permit Application Status

PRRES20242360


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242360
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK.
05/10/2024
05/24/2024
11/13/2024
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
PAUL@BELLAHHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/24/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/24/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/24/2024
9110078-Valuation Fee New Single Family $2,185.19 $2,185.19 Paid 05/24/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/25/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/25/2025
-As-graded plot plan is required. Provide a swale along the rear of the lot **Provide erosion control around storm inlet -Provide sewer tracer wire port at grade **where is the sewer shutoff valve access and tracer port? -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections **I don’t see the two through carriage bolts, especially at the south post. Verification is required
Footing Inspection - Residential Passed 06/12/2024
Informational
06/12/2024
FOOTING APPROVED BY ENGINEER
Erosion Control Inspection Residential Partial 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
Erosion control installed
Underslab Plumbing Inspection - Residential Passed 6/12/2024 6/12/2024 06/12/2024
Erosion Control Inspection Residential Partial 7/22/2024 07/22/2024
Misc
Informational
06/12/2024
Erosion control installed
Sewer Service Inspection - R Passed 7/22/2024 07/22/2024
Electrical Service Inspection Passed 9/20/2024 9/20/2024 09/20/2024
Gas Service Inspection - Residential Passed 9/20/2024 9/20/2024 09/20/2024
All Rough Inspection - Residential Failed 9/20/2024 9/20/2024 09/20/2024
Misc
Corrective Action Required
09/20/2024
**Restore erosion control along rear lot -Nail seams at garage PFH wall @3” oc; strap adjacent to opening -Toe nail joists to wall top plates (4-8d) -Solid block ends of double joists supporting knee wall above garage -Fb garage duct/plumbing chase from horizontal space; fb chase in laundry from joist space -Nail corner studs 16d@12” oc or equivalent nailing -Fasten fireplace to framing -Fb fireplace space from roof space -Nail siding to studs at step flashings -Shim gaps between rafters and bearing wall above laundry -Provide cantilevered joist/deck framing per plan 2/S3.3. Install Simpson LS90 first, then solid blocking after I verify; install H2.5 per detail; providers screw for ledger @ 16”, double every other; provide two 1/2” through bolts at beam-post connections -Support double header joist above furnace switch at both ends -Block rim-parallel joists @ 4 ft interval -Siding nails missing the sill plates at north wall -Tighten SE cable connector above main service panel -Protect wiring running across bottom of joists **DO NOT INSULATE
Erosion Control Inspection Residential Failed 9/20/2024 9/20/2024 09/20/2024
Misc
Corrective Action Required
09/20/2024
**Restore erosion control along rear lot
All Rough Inspection - Residential Failed 9/25/2024 9/25/2024 09/25/2024
Misc
Corrective Action Required
09/20/2024
**Restore erosion control along rear lot -Nail siding to studs at step flashings **Exterior wall of middle bedroom **OK TO INSULATE
All Rough Inspection - Residential Passed 9/27/2024 9/27/2024 09/27/2024
Misc
Resolved
09/27/2024
**Restore erosion control along rear lot -Nail siding to studs at step flashings **Exterior wall of middle bedroom **OK TO INSULATE
Driveway Inspection Partial 2/3/2025 2/3/2025 02/03/2025
Misc
Informational
02/03/2025
2-2-25 NS site visited and it appears driveway meets city’s standards for pre-pour
Erosion Control Inspection Residential Passed 03/25/2025
Misc
Resolved
03/25/2025
**Restore erosion control along rear lot
Occupancy Inspection - Codes Residential Failed 3/25/2025 3/25/2025 03/25/2025
Misc
Corrective Action Required
03/25/2025
-Driveway not approved -Deck piers not approved by city -As-graded plot plan is required. Provide a swale along the rear of the lot -Min 36” downspout extension from wall. Same for sump pump extension. -Seal above meter, seal exterior lights, etc -Provide sewer tracer wire port at grade -Secure ENT raceway within 3 ft of grinder pump controller -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Stair handrail shall be continuous and uninterrupted for straight stair flight -Tighten down the ufer grounding clamp set screw -Service panel cover missing two screws -Remove foundation wall metal ties -Fb floor penetration underneath master tub
Driveway Inspection Passed 3/26/2025 3/26/2025 03/26/2025
Misc
Informational
02/03/2025
2-2-25 NS site visited and it appears driveway meets city’s standards for pre-pour 3-26-25 NS site visited and it appears driveway meets city standards. No sidewalk. Passed
Plot Plan Inspection Passed 4/25/2025 04/25/2025
Occupancy Inspection - Codes Residential Failed 4/25/2025 4/25/2025 04/25/2025
Misc
Corrective Action Required
03/25/2025
-As-graded plot plan is required. Provide a swale along the rear of the lot **Provide erosion control around storm inlet -Provide sewer tracer wire port at grade **where is the sewer shutoff valve access and tracer port? -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections **I don’t see the two through carriage bolts, especially at the south post
Occupancy Inspection - Codes Residential Ready for Temp CO 04/25/2025
Misc
Corrective Action Required
04/25/2025
-As-graded plot plan is required. Provide a swale along the rear of the lot **Provide erosion control around storm inlet -Provide sewer tracer wire port at grade **where is the sewer shutoff valve access and tracer port? -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections **I don’t see the two through carriage bolts, especially at the south post. Verification is required
Documents & Images
Date Uploaded File Type Document Name
05/10/2024 Lot 25 Permit Application
05/10/2024 Lot 25 Tax Excise Application
05/17/2024 Permit Codes Residential Plan Review
05/17/2024 Approved Plans APPROVED PLANS
05/21/2024 Plot Plan APPROVED PLOT PLAN
05/21/2024 Permit Codes Residential Plan Review
05/24/2024 Permit DS Building Permit
05/24/2024 Receipt Receipt for transaction: 2024-003961
05/30/2024 3RD Party Insp Report 3rd Party Footing Inspection Report 5-22-24
05/31/2024 M L Crose 1812 NE Lashbrook Cir LSMO Woodland Oaks Lot 25 Bellah Homes P 2024-2360 3rd Party Footing Inspection Report Revised 5-31-24
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
04/24/2025 Plot Plan APPROVED AS BUILT PLOT PLAN
04/25/2025 Letter INSPECTION SUMMARY
04/25/2025 Letter INSPECTION SUMMARY
04/25/2025 Letter INSPECTION SUMMARY
04/25/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/25/2025 Receipt Receipt for transaction:2025-002615
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.