Summary
PRRES20242328
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES.
05/08/2024
05/21/2024
11/11/2024
06/10/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/21/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/21/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/21/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/21/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/21/2024
9110078-Valuation Fee New Single Family $1,205.74 $1,205.74 Paid 05/21/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/14/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/14/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/19/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 7/22/2024 07/22/2024
Miscellaneous Correction
Informational
07/22/2024
Erosion control measures are in place and must be maintained until CofO
Footing Inspection - Residential Passed 7/22/2024 07/22/2024
Miscellaneous Correction
Informational
07/22/2024
Footing was passed by a third party. No mention of exterior piers were in the footing report
Sewer Service Inspection - R Passed 7/26/2024 07/26/2024
Water Service Inspection - R Passed 7/26/2024 07/26/2024
Erosion Control Inspection Residential Partial 7/31/2024 07/31/2024
Miscellaneous Correction
Informational
07/22/2024
Erosion control measures are in place and must be maintained until CofO
Misc
Informational
07/31/2024
Erosion control measures are in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 7/31/2024 7/31/2024 07/31/2024
Erosion Control Inspection Residential Partial 8/14/2024 08/14/2024
Miscellaneous Correction
Resolved
08/14/2024
Erosion control measures are in place and must be maintained until CofO
Misc
Resolved
08/14/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Informational
08/14/2024
Erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Partial 11/5/2024 11/05/2024
Miscellaneous Correction
Informational
08/14/2024
Erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Partial 12/4/2024 12/04/2024
Miscellaneous Correction
Informational
11/05/2024
Erosion control measures are in place and must be maintained until CofO
Electrical Service Inspection Passed 12/4/2024 12/04/2024
Gas Service Inspection - Residential Passed 12/4/2024 12/04/2024
All Rough Inspection - Residential Not Ready 12/4/2024 12/4/2024 12/04/2024
Miscellaneous Correction
Corrective Action Required
12/04/2024
- House has been insulated before inspection - REMOVE ALL INSULATION before scheduling all rough inspection - Walk your property before scheduling inspections Not ready for inspection
All Rough Inspection - Residential Failed 12/11/2024 12/11/2024 12/11/2024
Miscellaneous Correction
Resolved
12/11/2024
- House has been insulated before inspection - REMOVE ALL INSULATION before scheduling all rough inspection - Walk your property before scheduling inspections Not ready for inspection
Misc
Corrective Action Required
12/11/2024
- Solid block sheeting break above top plate in front of geat room - Missing nails in 3 stud shoes at batroom 1
Erosion Control Inspection Residential Partial 12/16/2024 12/16/2024
Miscellaneous Correction
Informational
12/04/2024
Erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 12/16/2024 12/16/2024 12/16/2024
Misc
Corrective Action Required
12/11/2024
- Missing nails in 3 stud shoes at hallway batroom. **Not done **OK TO INSULATE **Make sure to install flashing above window trims
Erosion Control Inspection Residential Partial 12/17/2024 12/17/2024
Miscellaneous Correction
Informational
12/16/2024
Erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Passed 12/17/2024 12/17/2024 12/17/2024
Misc
Informational
12/17/2024
**OK TO ROCK **Install dryer electrical outlet box
Erosion Control Inspection Residential Partial 1/27/2025 01/27/2025
Miscellaneous Correction
Informational
12/17/2024
Erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 01/31/2025
Misc
Informational
01/31/2025
1-31-25 Dustin A, DW was framed and aggregate is compacted. Approved to pour
Sidewalk Inspection Partial 1/31/2025 1/31/2025 01/31/2025
Misc
Informational
01/31/2025
1-31-25 Dustin A, SW is formed and compacted, Slopes are in compliance. Approved to pour
Driveway Inspection Partial 2/7/2025 2/7/2025 02/07/2025
Misc
Informational
01/31/2025
1-31-25 Dustin A, DW was framed and aggregate is compacted. Approved to pour 020/7/25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Partial 2/7/2025 2/7/2025 02/07/2025
Misc
Informational
01/31/2025
1-31-25 Dustin A, SW is formed and compacted, Slopes are in compliance. Approved to pour 02/07/25 Jamie S, SW slopes are in compliance with city standards.
Erosion Control Inspection Residential Failed 2/11/2025 02/11/2025
Miscellaneous Correction
Resolved
02/11/2025
Erosion control measures are in place and must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/11/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Front waddles are damaged and or missing in spots and are not longer effective - Spoil pile in the backyard does not have erosion control around it
Occupancy Inspection - Codes Residential Not Ready 2/11/2025 2/11/2025 02/11/2025
Miscellaneous Correction
Corrective Action Required
02/11/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Front waddles are damaged and or missing in spots and are not longer effective - Spoil pile in the backyard does not have erosion control around it - House is not ready for an occupancy inspection due to no exterior garage lights being installed and No guard rail being installed at the front porch. THIS IS NOT A COMPLETE LIST Walk your property before scheduling your inspections
Occupancy Inspection - Codes Residential Failed 2/13/2025 2/13/2025 02/13/2025
Miscellaneous Correction
Resolved
02/13/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Front waddles are damaged and or missing in spots and are not longer effective - Spoil pile in the backyard does not have erosion control around it - House is not ready for an occupancy inspection due to no exterior garage lights being installed and No guard rail being installed at the front porch. THIS IS NOT A COMPLETE LIST Walk your property before scheduling your inspections No improvements were made since last inspection The City of Lees Summit has a policy to decline inspections until proper erosion control measures are in place. Erosion control measures must be in place, not just called in to be installed. 02/13/25 KBEARD 9:20am
Miscellaneous Correction
Corrective Action Required
02/13/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Front waddles are damaged and or missing in spots and are not longer effective - Spoil pile in the backyard does not have erosion control around it - House is not ready for an occupancy inspection due to no exterior garage lights being installed and No guard rail being installed at the front porch. THIS IS NOT A COMPLETE LIST Walk your property before scheduling your inspections No improvements were made since last inspection The City of Lees Summit has a policy to decline inspections until proper erosion control measures are in place. Erosion control measures must be in place, not just called in to be installed. 02/13/25 KBEARD 9:20am
Erosion Control Inspection Residential Partial 2/14/2025 02/14/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/14/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Front waddles are damaged and or missing in spots and are not longer effective - Spoil pile in the backyard does not have erosion control around it
Misc
Corrective Action Required
02/14/2025
Erosion control is in place at time of inspection
Occupancy Inspection - Codes Residential Failed 2/24/2025 2/24/2025 02/24/2025
Misc
Resolved
02/24/2025
provide handrail at front steps - Address excessive slop of front porch - Provide guard at front porch porch - Open electrical outside garage - Lock out in panel for water heater - Complete hardware at owner entrance door - Dead outlet basement bathroom - GFCI protection required in mechanical room - Secure electrical whip of water heater by conduit - Secondary lock at front door - Complete deck , deck stairs, landing - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Provide gutters with downspouts, splash pads to divert water at least 36” away from foundation - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck - Pay outstanding fees
Miscellaneous Correction
Corrective Action Required
02/24/2025
provide handrail at front steps - Address excessive slop of front porch - Provide guard at front porch porch - Open electrical outside garage - Lock out in panel for water heater - Complete hardware at owner entrance door - Dead outlet basement bathroom - GFCI protection required in mechanical room - Secure electrical whip of water heater by conduit - Secondary lock at front door - Complete deck , deck stairs, landing - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Provide gutters with downspouts, splash pads to divert water at least 36” away from foundation - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck - Pay outstanding fees
Piers/Caissons Inspection - Residential Failed 2/24/2025 2/24/2025 02/24/2025
Miscellaneous Correction
Corrective Action Required
02/24/2025
Piers were completed without inspection
Occupancy Inspection - Codes Residential Failed 2/14/2025 2/14/2025 02/25/2025
Misc
Resolved
02/24/2025
provide handrail at front steps - Address excessive slop of front porch - Provide guard at front porch porch - Open electrical outside garage - Lock out in panel for water heater - Complete hardware at owner entrance door - Dead outlet basement bathroom - GFCI protection required in mechanical room - Secure electrical whip of water heater by conduit - Secondary lock at front door - Complete deck , deck stairs, landing - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Provide gutters with downspouts, splash pads to divert water at least 36” away from foundation - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck - Pay outstanding fees
Miscellaneous Correction
Corrective Action Required
02/24/2025
- Address excessive slop of front porch - Provide guard at front porch porch - Open electrical outside garage - Lock out in panel for water heater - Complete hardware at owner entrance door - Dead outlet basement bathroom - GFCI protection required in mechanical room - Secure electrical whip of water heater by conduit - Secondary lock at front door - Complete deck , deck stairs, landing - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Provide gutters with downspouts, splash pads to divert water at least 36” away from foundation - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck No improvements since last inspection. Please walk your property before scheduling inspections Not ready. KBEARD 02/24/25 9am
Piers/Caissons Inspection - Residential Passed 2/25/2025 2/25/2025 02/25/2025
Miscellaneous Correction
Resolved
02/25/2025
Piers were completed without inspection
Occupancy Inspection - Codes Residential Failed 3/3/2025 3/3/2025 03/03/2025
Miscellaneous Correction
Resolved
03/03/2025
provide handrail at front steps - Address excessive slop of front porch - Provide guard at front porch porch - Open electrical outside garage - Lock out in panel for water heater - Complete hardware at owner entrance door - Dead outlet basement bathroom - GFCI protection required in mechanical room - Secure electrical whip of water heater by conduit - Secondary lock at front door - Complete deck , deck stairs, landing - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Provide gutters with downspouts, splash pads to divert water at least 36” away from foundation - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck - Pay outstanding fees
Miscellaneous Correction
Corrective Action Required
03/03/2025
-Address excessive slop of front porch -Owners entrance door will not completely seal shut - GFCI protection required in mechanical room by light receptacle - Secure electrical hot water heater whip - Secondary lock at front door - Seal exterior penetrations - Sump discharge to be 36” away from foundation - Install splash pads - Final grading and sod - Uncover water meter for inspection - Driveway inspection pending - Sidewalk inspection pending - Revision of plot plan to address the location of deck
Driveway Inspection Passed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/07/2025
1-31-25 Dustin A, DW was framed and aggregate is compacted. Approved to pour 02/7/25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Passed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/07/2025
1-31-25 Dustin A, SW is formed and compacted, Slopes are in compliance. Approved to pour 02/07/25 Jamie S, SW slopes are in compliance with city standards.
Plot Plan Inspection Passed 3/13/2025 03/13/2025
Erosion Control Inspection Residential Partial 3/13/2025 03/13/2025
Misc
Corrective Action Required
02/14/2025
Erosion control is in place at time of inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 3/13/2025 3/13/2025 03/13/2025
Miscellaneous Correction
Corrective Action Required
03/03/2025
- Land sewer trace wire to grade - Sump discharge to be 36” away from foundation - Install splash pads - Final grading and sod - Lower water meter and pit to grade
Occupancy Inspection - Codes Residential Ready for Temp CO 04/04/2025
Miscellaneous Correction
Corrective Action Required
03/13/2025
- Land sewer trace wire to grade - Sump discharge to be 36” away from foundation - Install splash pads - Final grading and sod - Lower water meter and pit to grade
Misc
Informational
04/04/2025
EXTENTION REQUEST APPROVED Shawn Hoffman 04/04/2025 9:04 AM
Erosion Control Inspection Residential Passed 05/16/2025
Misc
Resolved
05/16/2025
Erosion control is in place at time of inspection
Occupancy Inspection - Codes Residential Failed 5/16/2025 5/16/2025 05/16/2025
Miscellaneous Correction
Corrective Action Required
04/04/2025
Pay outstanding fees
Misc
Resolved
05/16/2025
EXTENTION REQUEST APPROVED Shawn Hoffman 04/04/2025 9:04 AM
Occupancy Inspection - Codes Residential Full C of O 6/10/2025 6/10/2025 06/10/2025
Miscellaneous Correction
Resolved
06/10/2025
Pay outstanding fees
Documents & Images
Date Uploaded File Type Document Name
05/08/2024 CB #151 - Permit Application
05/15/2024 Permit Codes Residential Plan Review
05/21/2024 Plot Plan APPROVED PLOT PLAN
05/21/2024 Approved Plans APPROVED PLANS
05/21/2024 Approved Plans APPROVED TRUSS PACKAGE
05/21/2024 Approved Plans APPROVED TRUSS LAYOUT
05/21/2024 Permit Codes Residential Plan Review
05/21/2024 Permit DS Building Permit
05/21/2024 Receipt Receipt for transaction:2024-003709
07/19/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Receipt Receipt for transaction:2024-009328
12/16/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
01/27/2025 Letter INSPECTION SUMMARY
01/27/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/13/2025 Letter INSPECTION SUMMARY
02/13/2025 Letter INSPECTION SUMMARY
02/13/2025 Letter INSPECTION SUMMARY
02/14/2025 Letter INSPECTION SUMMARY
02/14/2025 Receipt Receipt for transaction:2025-000937
02/24/2025 Letter INSPECTION SUMMARY
02/24/2025 Letter INSPECTION SUMMARY
02/24/2025 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/13/2025 Plot Plan 3-13-25 APPROVED PLOT PLAN
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001553
04/04/2025 CB #151 - TCO Extension 4_4_25
04/04/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/19/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/19/2025 Receipt Receipt for transaction:2025-003494
06/10/2025 Letter Codes Final Certificate of Occupancy
06/10/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.