Permit Application Status

PRRES20241045


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241045
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX. FINISHED/UNFINISHED BASEMENT. SUSEPENDED SLAB. COVERED DECK.
03/06/2024
04/02/2024
09/07/2024
03/13/2025
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,593.18 $2,593.18 Paid 04/02/2024
8331401-Water Tap Fee $7,520.00 $7,520.00 Paid 04/02/2024
8350015-Water Meter Fee $1,360.92 $1,360.92 Paid 04/02/2024
8331507-Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 04/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/02/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 04/02/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/23/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/23/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/27/2025
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/8/2024 10/8/2024 04/29/2024
Footing Inspection - Residential Passed 5/20/2024 5/20/2024 05/20/2024
Sewer Service Inspection - R Passed 6/19/2024 6/19/2024 06/19/2024
Misc
Informational
06/19/2024
1431 OK 1433 OK
Water Service Inspection - R Partial 6/19/2024 6/19/2024 06/19/2024
Misc
Corrective Action Required
06/19/2024
PARTIAL: POLY OUT OF FOUNDATION ON BOTH 1431,1433
Erosion Control Inspection Residential Partial 6/19/2024 06/19/2024
Misc
Corrective Action Required
06/19/2024
OK AT TIME OF INSPECTION.
Underslab Plumbing Inspection - Residential Passed 6/21/2024 6/21/2024 06/21/2024
Underslab Electrical Inspection - Residential Passed 6/21/2024 6/21/2024 06/21/2024
Erosion Control Inspection Residential Partial 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
OK AT TIME OF INSPECTION.
Misc
Informational
08/01/2024
-Erosion control was in compliance at the time of the inspection
Erosion Control Inspection Residential Failed 8/15/2024 08/15/2024
Misc
Resolved
08/15/2024
OK AT TIME OF INSPECTION.
Misc
Resolved
08/15/2024
-Erosion control was in compliance at the time of the inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - TRIM TALL VEGETATION - REPAIR SILT FENCE - PICK UP TRASH FROM LOT
Erosion Control Inspection Residential Partial 10/8/2024 10/08/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - TRIM TALL VEGETATION - REPAIR SILT FENCE - PICK UP TRASH FROM LOT
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Not Ready 10/8/2024 10/8/2024 10/08/2024
Miscellaneous Correction
Corrective Action Required
10/08/2024
1431 and 1433 SW Winthrop. All rough 1433 -Nail inside corner of entry to garage to code -Double LVL in entry on north side needs another stud under it for proper load transfer (only one stud now) -Nail corners of bedroom 2 to code -Secure gas line at fire place -Check angle of LIB in master bedroom -Add another purlin above living room for 4 feet on center -Anchor bolts in sole plate next to overhead garage door needs to be located in the middle 1/3 of plate -Steel Ibeam in basement storage/storm does not sit on the required 3 inches of concrete for support -Fire block top plate at the end of the hallway between storage and bedroom 3 -Vertically fire block basement walls every 10 feet on center Fire blocking was not completed in the basement and inspection was stopped This is not a complete Not ready for inspection
Electrical Service Inspection Failed 10/8/2024 10/8/2024 10/08/2024
Miscellaneous Correction
Corrective Action Required
10/08/2024
All rough was not completed so this electrical inspection was canceled
Electrical Service Inspection Passed 10/9/2024 10/9/2024 10/09/2024
Miscellaneous Correction
Informational
10/09/2024
1431 and 1433
All Rough Inspection - Residential Failed 10/9/2024 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
Misc
Corrective Action Required
10/09/2024
1431 and 1433 SW Winthrop. All rough 1433 -Nail inside corner of entry to garage to code -Double LVL in entry on north side needs another stud under it for proper load transfer (only one stud now) -Nail corners of bedroom 2 to code -Secure gas line at fire place -Check angle of LIB in master bedroom -Add another purlin above living room for 4 feet on center -Anchor bolts in sole plate next to overhead garage door needs to be located in the middle 1/3 of plate -Steel Ibeam in basement storage/storm does not sit on the required 3 inches of concrete for support 1431 _ add stud under LVL at entry garage side ( only 1) - Anchor CSST within 12” of fireplace - Purlin struts to be 48” OC in garage - Stud shoes in master bathroom missing nails - Check angle of LIB in master bedroom - Joist hanger required at basement next to LVL and bottom of stairs
Gas Service Inspection - Residential Passed 10/8/2024 10/9/2024 10/09/2024
Misc
Informational
10/09/2024
1431 and 1433
All Rough Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Misc
Resolved
10/11/2024
1431 and 1433 SW Winthrop. All rough 1433 -Nail inside corner of entry to garage to code -Double LVL in entry on north side needs another stud under it for proper load transfer (only one stud now) -Nail corners of bedroom 2 to code -Secure gas line at fire place -Check angle of LIB in master bedroom -Add another purlin above living room for 4 feet on center -Anchor bolts in sole plate next to overhead garage door needs to be located in the middle 1/3 of plate -Steel Ibeam in basement storage/storm does not sit on the required 3 inches of concrete for support 1431 _ add stud under LVL at entry garage side ( only 1) - Anchor CSST within 12” of fireplace - Purlin struts to be 48” OC in garage - Stud shoes in master bathroom missing nails - Check angle of LIB in master bedroom - Joist hanger required at basement next to LVL and bottom of stairs
Erosion Control Inspection Residential Partial 10/11/2024 10/11/2024
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
Rated Assembly Inspection Partial 8/1/2024 10/16/2024
Rated Assembly Inspection Partial 10/17/2024 10/17/2024 10/17/2024
MISC
Corrective Action Required
10/17/2024
ATTIC SPACE AND RIM BOARD 1431 - Pack gap from duckwork to wall with rock wool 1433 - Seal gap behind furnace
Rated Assembly Inspection Partial 10/18/2024 10/18/2024 10/18/2024
MISC
Resolved
10/18/2024
ATTIC SPACE AND RIM BOARD 1431 - Ok 1433 - Ok
Water Service Inspection - R Passed 10/22/2024 10/22/2024
Misc
Informational
10/22/2024
OK on BOTH 1431,1433
Rated Assembly Inspection Failed 10/30/2024 10/30/2024 10/30/2024
Misc
Corrective Action Required
10/30/2024
ATTIC AND RIM ARE APPROVED - PLANS CALL FOR 7" O.C. FIELD AND EDGE, FILL IN LOCATIONS THROUGHOUT WERE SCREWS EXCEED THE MINIMUM
Erosion Control Inspection Residential Failed 10/31/2024 10/31/2024
Miscellaneous Correction
Resolved
10/31/2024
Full erosion control measures are in place and must be properly maintained until CofO
Miscellaneous Correction
Corrective Action Required
10/31/2024
Silt fence at property line and street has been damaged and needs to be repaired or replaced. Full erosion control measures must be in place and properly maintained until CofO
Rated Assembly Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Resolved
10/31/2024
ATTIC AND RIM ARE APPROVED - PLANS CALL FOR 7" O.C. FIELD AND EDGE, FILL IN LOCATIONS THROUGHOUT WERE SCREWS EXCEED THE MINIMUM
Driveway Inspection Passed 12/3/2024 12/3/2024 12/06/2024
Misc
Informational
12/03/2024
12-3-24 BR Driveway is frame and aggerate is place plus compacted ready for concrete, 12-6-24 BR Driveway is constructed to LS specifications.
Sidewalk Inspection Passed 12/16/2024 12/16/2024 12/20/2024
Misc
Informational
12/12/2024
12-12-24 BR Sidewalk is formed up with aggregate places and compacted ready for concrete. 12-16-24 BR Sidewalk was poured to LS specification. Prior to inspection the existing sidewalk that is adjacent to new sidewalk is damage to existing sidewalk and will need to be repaired. 12-20-24 BR Existing sidewalk that was damage is now repaired.
Sidewalk Inspection Passed 12/20/2024 12/20/2024 12/20/2024
Misc
Informational
12/12/2024
12-12-24 BR Sidewalk is formed up with aggregate places and compacted ready for concrete. 12-16-24 BR Sidewalk was poured to LS specification. Prior to inspection the existing sidewalk that is adjacent to new sidewalk is damage to existing sidewalk and will need to be repaired. 12-20-24 BR Existing sidewalk that was damage is now repaired.
Occupancy Inspection - Codes Residential Ready for Temp CO 1/15/2025 1/15/2025 01/15/2025
Miscellaneous Correction
Corrective Action Required
01/15/2025
Unit 1433 needs the sump pump receptable to state it is non GFCI protected Both units -Exterior could not be verified due to snow on the ground - Plot plan needs to pass Unit 1431 passed for TCO only This is a partial list only becausew of the ground conditions
Plot Plan Inspection Failed 1/15/2025 01/15/2025
Miscellaneous Correction
Corrective Action Required
01/15/2025
Plot plan could not be completed due to the amount of snow coverage on the ground
Occupancy Inspection - Codes Residential Ready for Temp CO 1/22/2025 1/22/2025 01/22/2025
Miscellaneous Correction
Resolved
01/22/2025
Unit 1433 needs the sump pump receptable to state it is non GFCI protected Both units -Exterior could not be verified due to snow on the ground - Plot plan needs to pass Unit 1431 passed for TCO only This is a partial list only becausew of the ground conditions
Miscellaneous Correction
Corrective Action Required
01/22/2025
Both units passed for TCO only Both units -Exterior could not be verified due to snow on the ground - Plot plan needs to pass - Pay $125 fee associated with this permit This is a partial list only because of the ground conditions
Plot Plan Inspection Passed 2/27/2025 02/27/2025
Miscellaneous Correction
Resolved
02/27/2025
Plot plan could not be completed due to the amount of snow coverage on the ground
Occupancy Inspection - Codes Residential Ready for Temp CO 2/27/2025 02/27/2025
Miscellaneous Correction
Resolved
02/27/2025
Both units passed for TCO only Both units -Exterior could not be verified due to snow on the ground - Plot plan needs to pass - Pay $125 fee associated with this permit This is a partial list only because of the ground conditions
Miscellaneous Correction
Corrective Action Required
02/27/2025
Both units - Land sewer trace wire at grade - Sod and splash pads Builder sent in a TCO extension form
Driveway Inspection Passed 03/13/2025
Misc
Informational
12/03/2024
12-3-24 BR Driveway is frame and aggerate is place plus compacted ready for concrete, 12-6-24 BR Driveway is constructed to LS specifications. INSPECTED BY BOBBY RICHEST
Erosion Control Inspection Residential Passed 3/13/2025 03/13/2025
Miscellaneous Correction
Resolved
03/13/2025
Silt fence at property line and street has been damaged and needs to be repaired or replaced. Full erosion control measures must be in place and properly maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 3/13/2025 3/13/2025 03/13/2025
Miscellaneous Correction
Resolved
03/13/2025
Documents & Images
Date Uploaded File Type Document Name
03/06/2024 Tax Form - Lot 36
03/06/2024 Application - Lot 36
03/06/2024 Plans Plot Plan - Lot 36
03/06/2024 Plans Permit Set - Lot 36
03/11/2024 Permit Codes Residential Plan Review
03/20/2024 Revision Letter - Lot 36_pages
03/20/2024 Permit Set - Lot 36
03/20/2024 Plot Plan - Lot 36
03/21/2024 Approved Plans APPROVED PLANS
03/21/2024 Plot Plan APPROVED PLOT PLAN
03/21/2024 Permit Codes Residential Plan Review
04/02/2024 Permit DS Building Permit
04/02/2024 Receipt Receipt for transaction: 2024-002074
04/10/2024 Permit Set - Lot 36
04/11/2024 Approved Plans 4-11-24 APPROVED PLANS
04/22/2024 Lot 36 Pier Inspection
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
07/19/2024 3RD Party Insp Report THIRD PARTY SUSPENDAD GARAGE INSPECTION
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
10/22/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
01/15/2025 Letter INSPECTION SUMMARY
01/15/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter INSPECTION SUMMARY
01/23/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/23/2025 Receipt Receipt for transaction:2025-000415
02/25/2025 1433 TCO Extension
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/27/2025 Receipt Receipt for transaction:2025-001172
03/13/2025 Letter Codes Final Certificate of Occupancy
03/13/2025 Letter Field Certificate of Occupancy
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home