Permit Application Status

PRRES20240901


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240901
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES - DEFERRED.
02/28/2024
03/11/2024
09/01/2024
07/29/2024
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
CMH PARKS INC, Address:5000 CLAYTON RD  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DOUG@APGKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 03/11/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 03/11/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/11/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/11/2024
9110078-Valuation Fee New Single Family $1,786.68 $1,786.68 Paid 03/11/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/18/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/19/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 3/15/2024 03/15/2024
Miscellaneous Correction
Informational
03/15/2024
Full erosion control is in place and must be maintained until CofO
Footing Inspection - Residential Passed 3/15/2024 03/15/2024
Miscellaneous Correction
Informational
03/15/2024
-Footing plans did not include piers -Ufer is in garage west wall
Sewer Service Inspection - R Passed 3/26/2024 3/26/2024 03/26/2024
Water Service Inspection - R Passed 3/26/2024 3/26/2024 03/26/2024
Underslab Plumbing Inspection - Residential Failed 3/27/2024 3/27/2024 03/27/2024
Miscellaneous Correction
Corrective Action Required
03/27/2024
-Inspection could not be completed due to no access to the interior of the structure. - post address on structure
Erosion Control Inspection Residential Failed 3/27/2024 03/28/2024
Miscellaneous Correction
Informational
03/15/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
03/27/2024
Some silt fence is missing or damaged Full erosion control must be maintained until CofO
Erosion Control Inspection Residential Partial 3/28/2024 03/28/2024
Miscellaneous Correction
Informational
03/27/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
03/28/2024
Some silt fence is missing or damaged Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
03/28/2024
Full erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 3/28/2024 3/28/2024 03/28/2024
Miscellaneous Correction
Corrective Action Required
03/27/2024
-Inspection could not be completed due to no access to the interior of the structure. - post address on structure
All Rough Inspection - Residential Partial 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Informational
04/19/2024
-Garage CS-PF and front porch truss tie downs passed. Okay to cover This is a partial all rough pass only
Electrical Service Inspection Passed 5/1/2024 5/1/2024 05/01/2024
Gas Service Inspection - Residential Passed 5/1/2024 5/1/2024 05/01/2024
All Rough Inspection - Residential Failed 5/1/2024 5/1/2024 05/01/2024
Miscellaneous Correction
Informational
04/19/2024
-Garage CS-PF and front porch truss tie downs passed. Okay to cover This is a partial all rough pass only
Miscellaneous Correction
Corrective Action Required
05/01/2024
4412 SW Grindstone. All rough -Truss hold down screws needs to be located in the bottom of the top plate -Nail corners to code -Address spliced in plywood to truss and joist hanger in garage -Add stud pack under truss in garage to entry -Fire block steel post in garage to basement -Install LIB according to plans -Top of HVAC chase in garage to house has 7/16 plywood installed -Electrical nail guard needed in garage N/W corner -Tightened down anchor bolts Fire block hole in ceiling/ floor above garage -Fire block top of HVAC chase in garage entry -Stair stringers needs to be supported at least 1 1/2 inches on double 2x10 floor joist -Roof access sizes are not to code -Truss above second story entrance area is cut -2x10 cantilever over garage ceiling needs to sit on top and over hang 2 feet past Ibeam
Erosion Control Inspection Residential Partial 5/3/2024 05/03/2024
Miscellaneous Correction
Resolved
05/03/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Resolved
05/03/2024
Some silt fence is missing or damaged Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
05/03/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
05/03/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 5/3/2024 5/6/2024 05/06/2024
Miscellaneous Correction
Resolved
05/06/2024
-Garage CS-PF and front porch truss tie downs passed. Okay to cover This is a partial all rough pass only
Miscellaneous Correction
Corrective Action Required
05/01/2024
4412 SW Grindstone. All rough -Fire block steel post in garage to basement -Install LIB according to plans Fire block hole in ceiling/ floor above garage -Stair stringers needs to be supported at least 1 1/2 inches on double 2x10 floor joist Okay to insulate only.
All Rough Inspection - Residential Passed 5/7/2024 5/7/2024 05/07/2024
Miscellaneous Correction
Resolved
05/07/2024
4412 SW Grindstone. All rough -Fire block steel post in garage to basement -Install LIB according to plans Fire block hole in ceiling/ floor above garage -Stair stringers needs to be supported at least 1 1/2 inches on double 2x10 floor joist Okay to insulate only.
Erosion Control Inspection Residential Partial 06/10/2024
Miscellaneous Correction
Informational
05/03/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned
Erosion Control Inspection Residential Passed 6/13/2024 6/13/2024 06/12/2024
Miscellaneous Correction
Informational
06/10/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned 6-12-24 Dustin A, Street was clean and erosion control up
Driveway Inspection Partial 6/13/2024 6/13/2024 06/13/2024
Misc
Informational
06/13/2024
6-13-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Driveway Inspection Passed 6/20/2024 6/20/2024 06/19/2024
Misc
Informational
06/13/2024
6-13-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 6-19-24 PS Driveway approach meets LS specs
Erosion Control Inspection Residential Failed 6/20/2024 06/20/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/20/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Full erosion has been damaged, destroyed or is missing. Full erosion control must be maintained until CofO
Erosion Control Inspection Residential Partial 6/28/2024 06/28/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/28/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Full erosion has been damaged, destroyed or is missing. Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
06/28/2024
Full erosion control is in place and needs to be maintained until CofO
Plot Plan Inspection Passed 6/28/2024 06/28/2024
Occupancy Inspection - Codes Residential Failed 7/2/2024 7/2/2024 07/02/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
4412 SW grindstone. Occupancy Side of front porch needs a guard rail installed (over 30 inches high) Handrail going upstairs has been removed for painting (replace) Anti tip bracket on the oven is not working Fire block all Sheetrock gaps in the garage Garage to house door seal in not installed Garage to house door self closing hinge is not working First step going upstairs is over the allowable 7 3/4 riser height Light switch covers in master bathroom and bedroom 4 light is down because of painting HWT electrical whip is in contact with the cold water supply line Install AFCI breaker where required by code Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations Pay $75 fee associated with this permit
Occupancy Inspection - Codes Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
4412 SW grindstone. Occupancy Side of front porch needs a guard rail installed (over 30 inches high) Handrail going upstairs has been removed for painting (replace) Anti tip bracket on the oven is not working Fire block all Sheetrock gaps in the garage Garage to house door seal in not installed Garage to house door self closing hinge is not working First step going upstairs is over the allowable 7 3/4 riser height Light switch covers in master bathroom and bedroom 4 light is down because of painting HWT electrical whip is in contact with the cold water supply line Install AFCI breaker where required by code Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
07/17/2024
4412 SW grindstone. Occupancy (2) -Garage to house door self closing hinge is not working (will not fully shut and lock closed) -HWT electrical whip is in contact with the cold water supply line (still in contact) -Install AFCI breaker where required by code (microwave/range) -Sump pump extension is still not installed -Attach a/c disconnect within 12 inches of siding attachment -Seal gas line at siding Seal all exterior penetrations Pay $75 fee associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 7/18/2024 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
4412 SW grindstone. Occupancy Side of front porch needs a guard rail installed (over 30 inches high) Handrail going upstairs has been removed for painting (replace) Anti tip bracket on the oven is not working Fire block all Sheetrock gaps in the garage Garage to house door seal in not installed Garage to house door self closing hinge is not working First step going upstairs is over the allowable 7 3/4 riser height Light switch covers in master bathroom and bedroom 4 light is down because of painting HWT electrical whip is in contact with the cold water supply line Install AFCI breaker where required by code Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations Pay $75 fee associated with this permit
Miscellaneous Correction
Resolved
07/18/2024
4412 SW grindstone. Occupancy (2) -Garage to house door self closing hinge is not working (will not fully shut and lock closed) -HWT electrical whip is in contact with the cold water supply line (still in contact) -Install AFCI breaker where required by code (microwave/range) -Sump pump extension is still not installed -Attach a/c disconnect within 12 inches of siding attachment -Seal gas line at siding Seal all exterior penetrations Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
07/18/2024
Obtain irrigation permit
Erosion Control Inspection Residential Passed 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
Full erosion control is in place and needs to be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 7/29/2024 7/29/2024 07/29/2024
Miscellaneous Correction
Resolved
07/29/2024
Documents & Images
Date Uploaded File Type Document Name
03/01/2024 MN 117 LS Residental Permit Application_1
03/01/2024 MN 117 License_Tax_Application
03/05/2024 Permit Codes Residential Plan Review
03/07/2024 4412 SW GRINDSTONE CIR RESPONSE LETTER
03/07/2024 Approved Plans APPROVED PLANS
03/07/2024 Plot Plan APPROVED PLOT PLAN
03/07/2024 Permit Codes Residential Plan Review
03/11/2024 Permit DS Building Permit
03/11/2024 Receipt Receipt for transaction:2024-001508
03/15/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
04/01/2024 117 Manor at Stoney Creek - Crestwood - 040124
04/03/2024 Approved Plans APPROVED PLANS
04/18/2024 Engineer Report/Study 240613 C2 Repair
04/19/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/20/2024 240613 Layout
04/20/2024 240613 Seals
04/22/2024 Approved Plans APPROVED TRUSS PACKAGE
04/25/2024 3RD Party Insp Report 117 MN - CRESTWOOD - FRAMING - 240418
04/25/2024 240613 C2 Repair
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/02/2024 240613 A4A Repair
05/03/2024 4416 SW GRINDSTONE CIR - CITY INSPECTION COMMENTS - 240503
05/03/2024 Letter INSPECTION SUMMARY
05/03/2024 5-3-24 TRUSS REPAIR
05/06/2024 Letter INSPECTION SUMMARY
05/07/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
06/27/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
06/28/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/18/2024 Receipt Receipt for transaction:2024-005940
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/19/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/19/2024 Receipt Receipt for transaction:2024-005998
07/29/2024 Letter Codes Final Certificate of Occupancy
07/29/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home