Summary
PRRES20240900
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK - ROOF TRUSSES
02/28/2024
03/11/2024
09/01/2024
07/30/2024
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
CMH PARKS INC, Address:5000 CLAYTON RD  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
DOUG@APGKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/11/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 03/11/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 03/11/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 03/11/2024
9110078-Valuation Fee New Single Family $1,612.03 $1,612.03 Paid 03/11/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/18/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/18/2024 03/18/2024
Miscellaneous Correction
Informational
03/18/2024
Piers were not noted upon footing inspection Ufer is located along the garage S/W wall and main house
Erosion Control Inspection Residential Passed 3/18/2024 03/18/2024
Miscellaneous Correction
Informational
03/18/2024
Erosion control is in place at the time of footing inspection and must be maintained until CofO
Sewer Service Inspection - R Passed 3/26/2024 3/26/2024 03/26/2024
Water Service Inspection - R Passed 3/26/2024 3/26/2024 03/26/2024
Erosion Control Inspection Residential Failed 3/27/2024 03/27/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/27/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 3/27/2024 3/27/2024 03/27/2024
Miscellaneous Correction
Corrective Action Required
03/27/2024
-No address posted on structure -Full erosion control is not in place -inspection is denied
Erosion Control Inspection Residential Partial 3/28/2024 03/28/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/28/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Miscellaneous Correction
Informational
03/28/2024
Full erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 3/28/2024 3/28/2024 03/28/2024
Miscellaneous Correction
Corrective Action Required
03/27/2024
-No address posted on structure -Full erosion control is not in place -inspection is denied
All Rough Inspection - Residential Failed 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Corrective Action Required
04/19/2024
-Garage CS-PF needs to be nailed along the exterior top left of garage at the top plate -Front porch truss tie downs passed
All Rough Inspection - Residential Failed 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Corrective Action Required
04/19/2024
-Garage PFH and front porch trusses only approved to cover
Gas Service Inspection - Residential Passed 5/1/2024 5/1/2024 05/01/2024
Electrical Service Inspection Passed 5/1/2024 5/1/2024 05/01/2024
All Rough Inspection - Residential Failed 5/1/2024 5/1/2024 05/01/2024
Miscellaneous Correction
Resolved
05/01/2024
-Garage PFH and front porch trusses only approved to cover
Miscellaneous Correction
Corrective Action Required
05/01/2024
4416 SW Grindstone. All rough -Nail corners to code -Have engineer address where the fourth lvl to steel post and Ibeam in garage does not sit on the Ibeam -Attic access hatches sizes are not to code -Wrong size of ceiling plywood for Fire blocking was used in HVAC chases Install Lib’s according to plan -Stairway does not match plans. Have engineer address new stairway design -Stair stringers must bare 1 1/2 inches on 2x10 support beams
Erosion Control Inspection Residential Partial 5/3/2024 05/03/2024
Miscellaneous Correction
Resolved
05/03/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
05/03/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Passed 5/6/2024 5/6/2024 05/06/2024
Miscellaneous Correction
Resolved
05/06/2024
4416 SW Grindstone. All rough -Nail corners to code -Have engineer address where the fourth lvl to steel post and Ibeam in garage does not sit on the Ibeam -Attic access hatches sizes are not to code -Wrong size of ceiling plywood for Fire blocking was used in HVAC chases Install Lib’s according to plan -Stairway does not match plans. Have engineer address new stairway design -Stair stringers must bare 1 1/2 inches on 2x10 support beams
Piers/Caissons Inspection - Residential Passed 6/5/2024 6/5/2024 06/05/2024
Driveway Inspection Not Ready 6/7/2024 6/7/2024 06/07/2024
Misc
Corrective Action Required
06/07/2024
6-7-24 PS Driveway approach inspection failed, aggregate is required to be compacted, discussed requirement prior to inspection with contractor but not completed on site at inspection
Erosion Control Inspection Residential Partial 06/10/2024
Miscellaneous Correction
Informational
05/03/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned
Erosion Control Inspection Residential Passed 6/13/2024 6/13/2024 06/12/2024
Miscellaneous Correction
Informational
06/10/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned 6-12-24 Dustin A, Street was clean and erosion control up
Driveway Inspection Partial 6/12/2024 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
6-12-24 PS Driveway approach pre pour, forms in place, aggregate compacted, approved to pour
Driveway Inspection Passed 6/19/2024 6/19/2024 06/19/2024
Misc
Informational
06/12/2024
6-12-24 PS Driveway approach pre pour, forms in place, aggregate compacted, approved to pour 6-19-24 PS Driveway approach meets LS specs
Erosion Control Inspection Residential Failed 6/20/2024 06/20/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/20/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Full erosion has been damaged, destroyed or is missing. Full erosion control must be maintained until CofO
Erosion Control Inspection Residential Partial 6/28/2024 06/28/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/28/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Full erosion has been damaged, destroyed or is missing. Full erosion control must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
06/28/2024
Miscellaneous Correction
Informational
06/28/2024
Full erosion control measures are in place and needs to be maintained until CofO
Plot Plan Inspection Passed 6/28/2024 06/28/2024
Occupancy Inspection - Codes Residential Failed 7/2/2024 7/2/2024 07/02/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
4416 SW Hightown. Occupancy Front porch requires guard rails to be installed Fire block all garage Sheetrock gaps First step upstairs from the main entry has a riser height of greater than code allowance 7 3/4 of an inch House attic access hatch needs to be in place Light switch going down to the basement is not within reach of the main floor platform Bottom basement landing does not have the code required 36 inches of travel distance Bottom basement stair riser has a greater than the code will allow (7 3/4 inches) Electrical panel needs to be relabeled , some name are not readable Secure HWT whip at the top Exterior sod, sump pump extension splash pads are not installed Seal all exterior penetrations Pay $75 fee associated with this permit
Erosion Control Inspection Residential Partial 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
Full erosion control measures are in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
07/18/2024
Full erosion control measures are in place and needs to be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 7/23/2024 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
4416 SW Hightown. Occupancy Front porch requires guard rails to be installed Fire block all garage Sheetrock gaps First step upstairs from the main entry has a riser height of greater than code allowance 7 3/4 of an inch House attic access hatch needs to be in place Light switch going down to the basement is not within reach of the main floor platform Bottom basement landing does not have the code required 36 inches of travel distance Bottom basement stair riser has a greater than the code will allow (7 3/4 inches) Electrical panel needs to be relabeled , some name are not readable Secure HWT whip at the top Exterior sod, sump pump extension splash pads are not installed Seal all exterior penetrations Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
07/23/2024
Exterior sod, sump pump extension splash pads are not installed Seal all exterior penetrations Passed for TCO only
Occupancy Inspection - Codes Residential Full C of O 7/30/2024 7/30/2024 07/30/2024
Miscellaneous Correction
Resolved
07/30/2024
Miscellaneous Correction
Resolved
07/30/2024
Documents & Images
Date Uploaded File Type Document Name
03/01/2024 Application Form MN 116 LS Residental Permit Application_1
03/01/2024 Application Form MN 116 License_Tax_Application
03/04/2024 Permit Codes Residential Plan Review
03/05/2024 Permit Codes Residential Plan Review
03/05/2024 Plot Plan approved plot plan
03/05/2024 Permit Codes Residential Plan Review
03/11/2024 Permit DS Building Permit
03/11/2024 Receipt Receipt for transaction:2024-001506
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
04/01/2024 116 Manor at Stoney Creek - Serenity - 030424
04/01/2024 240612 Seals
04/01/2024 240612 Layout
04/04/2024 Approved Plans APPROVED TRUSS PACKAGE
04/04/2024 Approved Plans APPROVED REVISED PLANS
04/19/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/25/2024 116 Manor at Stoney Creek - Serenity - 040424
04/25/2024 Approved Plans APPROVED REVISED PLANS
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/03/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/07/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 MN 116 approved plot plan
06/20/2024 Letter INSPECTION SUMMARY
06/27/2024 Plot Plan approved as graded plot plan
06/28/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/18/2024 Receipt Receipt for transaction:2024-005940
07/18/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter Codes Final Certificate of Occupancy
07/30/2024 Letter Field Certificate of Occupancy
10/18/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/18/2024 Receipt Receipt for transaction:2024-008437
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home