Summary
PRRES20236052
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW TOWNHOME. UNFINISHED BASEMENT. ROOF TRUSSES. STOP WORK ORDER generated on 01/30/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 01/31/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
11/15/2023
11/22/2023
05/15/2024
08/22/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,933.68 $4,933.68 Paid 11/22/2023
8331401-Water Tap Fee $15,040.00 $15,040.00 Paid 11/22/2023
8350015-Water Meter Fee $2,721.84 $2,721.84 Paid 11/22/2023
8331507-Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 11/22/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/22/2023
7232302-Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 11/22/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/17/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/17/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/27/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/20/2023 12/20/2023
Miscellaneous Correction
Informational
12/20/2023
Footing inspected and signed off by a third party. Piers were not mentioned in the footing report.
Sewer Service Inspection - R Partial 1/3/2024 1/3/2024 01/03/2024
Miscellaneous Correction
Informational
01/03/2024
Unit 3710 passed. This is a partial pass only. Other units will be scheduled at a later date
Erosion Control Inspection Residential Failed 1/3/2024 01/03/2024
Miscellaneous Correction
Corrective Action Required
01/03/2024
Some silt fence has been damaged or torn down and repair or replacement is needed. Gravel from the street to the foundation needs to be spread.
Water Service Inspection - R Partial 1/4/2024 1/4/2024 01/04/2024
Miscellaneous Correction
Informational
01/04/2024
3710 water passed. This is a partial pass only. Other units will be scheduled at a later date.
Sewer Service Inspection - R Partial 1/4/2024 01/04/2024
Miscellaneous Correction
Informational
01/03/2024
Unit 3710 passed. This is a partial pass only. Other units will be scheduled at a later date
Miscellaneous Correction
Informational
01/04/2024
3712 sewer passed, this is a partial pass only. Other units will be scheduled at a later date. Units 3710 and 3712 passed only so far
Water Service Inspection - R Partial 1/5/2024 1/5/2024 01/05/2024
Miscellaneous Correction
Informational
01/04/2024
3710 water passed. This is a partial pass only. Other units will be scheduled at a later date.
Miscellaneous Correction
Informational
01/05/2024
3712 water passed, this is a partial pass only. 3712 and 3710 are the only units that have passed. Other units will be scheduled at a later date.
Sewer Service Inspection - R Partial 1/5/2024 1/5/2024 01/05/2024
Miscellaneous Correction
Informational
01/04/2024
Unit 3710 passed. This is a partial pass only. Other units will be scheduled at a later date
Miscellaneous Correction
Informational
01/04/2024
3712 sewer passed, this is a partial pass only. Other units will be scheduled at a later date. Units 3710 and 3712 passed only so far
Miscellaneous Correction
Informational
01/05/2024
3716 sewer passed. This is a partial pass only. Completed and passed sewer inspections are 3710,3712 and 3716
Sewer Service Inspection - R Passed 1/10/2024 1/10/2024 01/10/2024
Miscellaneous Correction
Informational
01/05/2024
Unit 3710 passed. This is a partial pass only. Other units will be scheduled at a later date
Miscellaneous Correction
Informational
01/05/2024
3712 sewer passed, this is a partial pass only. Other units will be scheduled at a later date. Units 3710 and 3712 passed only so far
Miscellaneous Correction
Informational
01/05/2024
3716 sewer passed. This is a partial pass only. Completed and passed sewer inspections are 3710,3712 and 3716
Water Service Inspection - R Passed 1/11/2024 01/11/2024
Miscellaneous Correction
Informational
01/05/2024
3710 water passed. This is a partial pass only. Other units will be scheduled at a later date.
Miscellaneous Correction
Informational
01/05/2024
3712 water passed, this is a partial pass only. 3712 and 3710 are the only units that have passed. Other units will be scheduled at a later date.
Underslab Plumbing Inspection - Residential Passed 2/1/2024 2/1/2024 02/01/2024
Underslab Electrical Inspection - Residential Passed 2/2/2024 2/1/2024 02/01/2024
Erosion Control Inspection Residential Partial 2/1/2024 02/01/2024
Miscellaneous Correction
Resolved
02/01/2024
Some silt fence has been damaged or torn down and repair or replacement is needed. Gravel from the street to the foundation needs to be spread.
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and needs to be maintained until CofO
All Rough Inspection - Residential Failed 2/14/2024 2/14/2024 02/14/2024
Miscellaneous Correction
Corrective Action Required
02/14/2024
All four units CSPF inspection 1) Interior hold down straps are not installed 2) Exterior sheeting is not nailed to the top plate 3) 5/8 inch anchor bolts are not in the middle 1/3 of the sole plate
All Rough Inspection - Residential Failed 2/23/2024 2/23/2024 02/23/2024
Miscellaneous Correction
Resolved
02/23/2024
All four units CSPF inspection 1) Interior hold down straps are not installed 2) Exterior sheeting is not nailed to the top plate
Miscellaneous Correction
Corrective Action Required
02/23/2024
All four units CSPF inspection 1) Interior hold down straps are not installed. Refer to IRC 602.10.4 for hold down strap sizing 2) Exterior sheeting is not nailed to the top plate CSPF inspection failed
All Rough Inspection - Residential Partial 3/1/2024 3/1/2024 03/01/2024
Miscellaneous Correction
Resolved
03/01/2024
This was a portal frame inspection only. —CSPF’s Passed on all four units.
Rated Assembly Inspection Failed 3/11/2024 3/11/2024 03/11/2024
Miscellaneous Correction
Corrective Action Required
03/11/2024
3710 SW Maryville. Rated assembly fire block plywood needs to be installed 4 foot from the fire rated wall Hole in plywood at ridge in fire block plywood needs to be repaired Hole in vertical wall at roof needs to be repaired All vertical wall sheet rock that has the outer paper damaged needs to be caulked with fire caulking 3712 regular plywood for roof was used within 4 feet of north fire wall Repair sheet rock paper in vertical south wall upstairs 3716 Fire block plywood at ridge has more than a 1/4 inch gap Repair all missing vertical sheet rock that has damaged sheet rock paper 3718 Fire block plywood at ridge has more than a 1/4 inch gap All plywood for roof needs to be fire block plywood within 4 feet of fire wall Repair sheet rock at roof
Gas Service Inspection - Residential Failed 3/11/2024 3/11/2024 03/11/2024
Miscellaneous Correction
Corrective Action Required
03/11/2024
-Can not see where gas lines are grounded at the HVAC unit -Gas lines are not bonded -3712 pressure gauge does not work
All Rough Inspection - Residential Failed 3/11/2024 3/11/2024 03/11/2024
Miscellaneous Correction
Corrective Action Required
03/11/2024
3710 SW Maryville all rough garage anchor bolts need to be in the middle 1/3 of 2x4 sole plate Garage anchor bolts need to be in between 4-12 inches from the ends of the sole plate Garage anchor bolt is missing in sole plate Nail guard plate is need in the powder bathroom for Radon pipe Nail missing in joist hanger in pantry Nails missing in joist hanger in kitchen by stairs 2x10 ceiling joist above the front porch has been cut within 2 inches from the edge Ceiling joist hangers on front porch are not installed LIB in entry closet is missing nails Attic access is missing joist hanger nails LIB in bedroom 1 is not on a 45 degree angle Bedroom 1 need’s outside corners nailed 12 inches on center Steel column post in basement is not secured to the ground 3712 two garage anchor bolts are not installed in the middle 1/3 of sole plate Garage to house north LIB is not on a 45 degree angle and is not nailed off Garage south LIB is not on a 45 degree angle Nails missing in joist hanger at double 2x10 andLVL in garage to house entry Nails missing at joist hanger in kitchen to upstairs Ceiling joist hangers on front porch are not installed Fire block top plate in kitchen at sink window LIB is missing in bedroom 1, 2 and 3 Steel column post in basement is not secured at the bottom 3716 garage anchor bolts are not within middle 1/3 of sole plate South side of garage needs to have tie down straps at the anchor bolts due to the jack studs not sitting down on the sole plate that is anchored Top plate in garage needs to be fire blocked Attic access hatch in garage has a wire running through it LIB’ missing throughout Fire block kitchen ceiling to upper floor decking (3) holes Fire block hole in decking at kitchen chase to up stairs Ceiling joist hangers on the front porch are not installed Tie down straps missing at bedroom 1 window Vent fan in bathroom 1 is not attached Steel column post in basement is not attached at the bottom 3718 anchor bolt in garage is not tightened down Anchor bolts in garage not installed in middle 1/3 of sole plate Top plate in garage needs to be fire blocked Wire is running through garage attic access hatch LIB’s are missing throughout Fire blocking is missing at great room ceiling to upper floor plywood Truss tie down screws missing in bedroom 1 at GB Fire block top of chase next to shower in bedroom 1 Nail all corners 12 inches on center Attic access has a HVAC duct within the headroom
Electrical Service Inspection Passed 3/11/2024 3/11/2024 03/11/2024
Rated Assembly Inspection Failed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Resolved
03/15/2024
3710 SW Maryville. Rated assembly fire block plywood needs to be installed 4 foot from the fire rated wall Hole in plywood at ridge in fire block plywood needs to be repaired Hole in vertical wall at roof needs to be repaired All vertical wall sheet rock that has the outer paper damaged needs to be caulked with fire caulking 3712 regular plywood for roof was used within 4 feet of north fire wall Repair sheet rock paper in vertical south wall upstairs 3716 Fire block plywood at ridge has more than a 1/4 inch gap Repair all missing vertical sheet rock that has damaged sheet rock paper 3718 Fire block plywood at ridge has more than a 1/4 inch gap All plywood for roof needs to be fire block plywood within 4 feet of fire wall Repair sheet rock at roof
Miscellaneous Correction
Corrective Action Required
03/15/2024
3710 SW Maryville. Rated assembly (2) fire block plywood needs to be installed 4 foot from the fire rated wall (new fire blocking plywood at ridge does not have full coverage on untreated plywood underneath) All vertical wall sheet rock that has the outer paper damaged needs to be caulked with fire caulking 3712 regular plywood for roof was used within 4 feet of north fire wall (seal new plywood used along both ends) 3716 Fire block plywood at ridge has more than a 1/4 inch gap (untreated plywood was used to fill in the gap) . Other side or ridge was never addressed Repair all missing vertical sheet rock that has damaged sheet rock paper
Gas Service Inspection - Residential Failed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Resolved
03/15/2024
-Can not see where gas lines are grounded at the HVAC unit -Gas lines are not bonded -3712 pressure gauge does not work
Miscellaneous Correction
Corrective Action Required
03/15/2024
Gas gauge at inspection read 0 PSI on unit 3712
All Rough Inspection - Residential Failed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Resolved
03/15/2024
3710 SW Maryville all rough garage anchor bolts need to be in the middle 1/3 of 2x4 sole plate Garage anchor bolts need to be in between 4-12 inches from the ends of the sole plate Garage anchor bolt is missing in sole plate Nail guard plate is need in the powder bathroom for Radon pipe Nail missing in joist hanger in pantry Nails missing in joist hanger in kitchen by stairs 2x10 ceiling joist above the front porch has been cut within 2 inches from the edge Ceiling joist hangers on front porch are not installed LIB in entry closet is missing nails Attic access is missing joist hanger nails LIB in bedroom 1 is not on a 45 degree angle Bedroom 1 need’s outside corners nailed 12 inches on center Steel column post in basement is not secured to the ground 3712 two garage anchor bolts are not installed in the middle 1/3 of sole plate Garage to house north LIB is not on a 45 degree angle and is not nailed off Garage south LIB is not on a 45 degree angle Nails missing in joist hanger at double 2x10 andLVL in garage to house entry Nails missing at joist hanger in kitchen to upstairs Ceiling joist hangers on front porch are not installed Fire block top plate in kitchen at sink window LIB is missing in bedroom 1, 2 and 3 Steel column post in basement is not secured at the bottom 3716 garage anchor bolts are not within middle 1/3 of sole plate South side of garage needs to have tie down straps at the anchor bolts due to the jack studs not sitting down on the sole plate that is anchored Top plate in garage needs to be fire blocked Attic access hatch in garage has a wire running through it LIB’ missing throughout Fire block kitchen ceiling to upper floor decking (3) holes Fire block hole in decking at kitchen chase to up stairs Ceiling joist hangers on the front porch are not installed Tie down straps missing at bedroom 1 window Vent fan in bathroom 1 is not attached Steel column post in basement is not attached at the bottom 3718 anchor bolt in garage is not tightened down Anchor bolts in garage not installed in middle 1/3 of sole plate Top plate in garage needs to be fire blocked Wire is running through garage attic access hatch LIB’s are missing throughout Fire blocking is missing at great room ceiling to upper floor plywood Truss tie down screws missing in bedroom 1 at GB Fire block top of chase next to shower in bedroom 1 Nail all corners 12 inches on center Attic access has a HVAC duct within the headroom
Miscellaneous Correction
Corrective Action Required
03/15/2024
3710 SW Maryville all rough. (2) garage anchor bolts need to be in the middle 1/3 of 2x4 sole Nail guard plate is need in the powder bathroom for Radon pipe 2x10 ceiling joist above the front porch has been cut within 2 inches from the edge (have engineers repair report) Attic access is missing joist hanger nails LIB in bedroom 1 is not on a 45 degree angle Bedroom 1 need’s outside corners nailed 12 inches on center 3712 two garage anchor bolts are not installed in the middle 1/3 of sole plate Garage to house north LIB is not on a 45 degree angle and is not nailed off Garage south LIB is not on a 45 degree angle LIB in bedroom 1, 2 and 3 are not on 45 degree angles 3716 South side of garage needs to have tie down straps at the anchor bolts due to the jack studs not sitting down on the sole plate that is anchored Top plate in garage needs to be fire blocked LIB’s throughout need to be installed at 45 degree angles Tie down straps missing at bedroom 1 window 3718 anchor bolt in garage missing every 4 feet along south wall Top plate in garage needs to be fire blocked Wire is running through garage attic access hatch LIB’s are missing throughout Nail all corners 12 inches on center
Rated Assembly Inspection Passed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
3710 SW Maryville. Rated assembly (2) fire block plywood needs to be installed 4 foot from the fire rated wall (new fire blocking plywood at ridge does not have full coverage on untreated plywood underneath) All vertical wall sheet rock that has the outer paper damaged needs to be caulked with fire caulking 3712 regular plywood for roof was used within 4 feet of north fire wall (seal new plywood used along both ends) 3716 Fire block plywood at ridge has more than a 1/4 inch gap (untreated plywood was used to fill in the gap) . Other side or ridge was never addressed Repair all missing vertical sheet rock that has damaged sheet rock paper
Gas Service Inspection - Residential Passed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
Gas gauge at inspection read 0 PSI on unit 3712
All Rough Inspection - Residential Passed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
3710 SW Maryville all rough. (2) garage anchor bolts need to be in the middle 1/3 of 2x4 sole Nail guard plate is need in the powder bathroom for Radon pipe 2x10 ceiling joist above the front porch has been cut within 2 inches from the edge (have engineers repair report) Attic access is missing joist hanger nails LIB in bedroom 1 is not on a 45 degree angle Bedroom 1 need’s outside corners nailed 12 inches on center 3712 two garage anchor bolts are not installed in the middle 1/3 of sole plate Garage to house north LIB is not on a 45 degree angle and is not nailed off Garage south LIB is not on a 45 degree angle LIB in bedroom 1, 2 and 3 are not on 45 degree angles 3716 South side of garage needs to have tie down straps at the anchor bolts due to the jack studs not sitting down on the sole plate that is anchored Top plate in garage needs to be fire blocked LIB’s throughout need to be installed at 45 degree angles Tie down straps missing at bedroom 1 window 3718 anchor bolt in garage missing every 4 feet along south wall Top plate in garage needs to be fire blocked Wire is running through garage attic access hatch LIB’s are missing throughout Nail all corners 12 inches on center
Rated Assembly Inspection Partial 3/25/2024 03/25/2024
Miscellaneous Correction
Corrective Action Required
03/25/2024
All units except for 3716 have passed their screw patterns This is a partial pass only
Rated Assembly Inspection Failed 3/26/2024 3/26/2024 03/26/2024
Miscellaneous Correction
Resolved
03/26/2024
All units except for 3716 have passed their screw patterns This is a partial pass only
Miscellaneous Correction
Corrective Action Required
03/26/2024
3716 is missing screws in closet of bedroom 1. (Failed) Other units have already passed
Rated Assembly Inspection Passed 3/27/2024 3/27/2024 03/27/2024
Miscellaneous Correction
Resolved
03/27/2024
3716 is missing screws in closet of bedroom 1. (Failed) Other units have already passed
Driveway Inspection Partial 4/3/2024 4/3/2024 04/03/2024
Misc
Informational
04/03/2024
4-3-24 PS pre pour inspection on approaches for units 3710, 3712, 3716, 3718 forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 4/3/2024 4/3/2024 04/03/2024
Misc
Informational
04/03/2024
4-3-24 PS Pre pour inspection on sidewalks along east side of building w/ approaches for units 3710, 3712, 3716, 3718 forms in place and aggregate compacted, approved to pour sidewalk along Holdbrooks Dr on north side TBD, recall for inspection on that sidewalk prior to pour
Sidewalk Inspection Partial 4/5/2024 04/05/2024
Misc
Informational
04/05/2024
4-5-24 Dustin A, Sw is formed to city specs on north side of hpouse. Approved to pour
Sidewalk Inspection Passed 4/12/2024 4/12/2024 04/12/2024
Misc
Informational
04/05/2024
4-5-24 Dustin A, Sw is formed to city specs on north side of hpouse. Approved to pour 4-12-24 Dustin A, Sw is poured to city specs.Passed
Erosion Control Inspection Residential Passed 04/25/2024
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and needs to be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Failed 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
Water meters in 3718,3716 and 3712 look to be below grade
Occupancy Inspection - Codes Residential Failed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
3710 SW Maryville. Occupancy Kitchen receptacles are not fully installed Hot water under the kitchen sink does not have a anti hammer device installed Stairs in garage needs guard rails installed Electrical panel does not have the required 3 feet of clearance in front of it 3712 Garage stairs needs guard rails installed 3716 Garage to house door knobs are not installed. Self closing and locking hinge can not be tested Garage stairs needs guard rails installed in Electrical face plates missing in kitchen and powder bathroom Electrical panel does not have the required 3 feet of clearance in front of it Seal top of A/C disconnect 3718 Electrical plate is missing at the kitchen backsplash Garage stairs needs a guard rail installed All units Sump pump extension are not installed Sod and splash pads are not installed 3718, 3716 and 3712 water meters are below grade Pay $50 fee on 3rd subsequent inspection
Driveway Inspection Passed 05/16/2024
Misc
Informational
04/03/2024
4-3-24 PS pre pour inspection on approaches for units 3710, 3712, 3716, 3718 forms in place and aggregate compacted, approved to pour 5-16-24 Dustin A, DW is poured to city specs, Passed
Sidewalk Inspection Passed 05/16/2024
Misc
Informational
05/16/2024
5-16-24 Dustin A, All sw has been poured to city specs and has passed
Occupancy Inspection - Codes Residential Failed 5/16/2024 5/16/2024 05/16/2024
Miscellaneous Correction
Corrective Action Required
05/16/2024
3710 SW Maryville. Occupancy Kitchen receptacles are not fully installed (receptacles installed needs spark rings installed) 3712 Passed for TCO only (pay $50 fee associated with permit as stated below before a TCO can be issued) 3716 Electrical face plates missing in kitchen (install spark rings in kitchen backsplash where missing) Relocated HWT has water line in contact with electrical Seal top of A/C disconnect 3718 Electrical plate is missing at the kitchen backsplash (install spark rings in kitchen backsplash where missing) Pay $50 fee associated with this permit All units Sump pump extension are not installed Sod and splash pads are not installed 3718, 3716 and 3712 water meters are below grade. Plot plan must pass
Occupancy Inspection - Codes Residential Ready for Temp CO 5/17/2024 5/17/2024 05/17/2024
Miscellaneous Correction
Informational
05/17/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade.
Occupancy Inspection - Codes Residential Ready for Temp CO 5/17/2024 05/17/2024
Miscellaneous Correction
Resolved
05/17/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade.
Miscellaneous Correction
Informational
05/17/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade.
Occupancy Inspection - Codes Residential Ready for Temp CO 6/27/2024 06/27/2024
Miscellaneous Correction
Resolved
06/27/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade.
Miscellaneous Correction
Corrective Action Required
06/27/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade. TCO extension sent in by builder
Erosion Control Inspection Residential Passed 8/12/2024 08/12/2024
Miscellaneous Correction
Resolved
08/12/2024
Full erosion control is in place and needs to be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/12/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Failed 8/12/2024 08/12/2024
Miscellaneous Correction
Resolved
08/12/2024
Water meters in 3718,3716 and 3712 look to be below grade
Miscellaneous Correction
Corrective Action Required
08/12/2024
-Water meters in 3716 and 3712 appears to be below grade. -Water meter for 3718 is covered -Water valves in lot 3710 are about 24 inches above grade
Plot Plan Inspection Passed 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
-Water meters in 3716 and 3712 appears to be below grade. -Water meter for 3718 is covered -Water valves in lot 3710 are about 24 inches above grade
Occupancy Inspection - Codes Residential Full C of O 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
3710 SW Maryville. Occupancy (2) Passed for TCO only 3712 Passed for TCO only 3716 Passed for TCO only 3718 Passed for TCO only All units Sump pump extension are not installed Sod and splash pads are not installed Plot plan must pass 3718, 3716, 3712 water meters are below grade. TCO extension sent in by builder
Documents & Images
Date Uploaded File Type Document Name
11/22/2023 Permit DS Building Permit
11/22/2023 Receipt Receipt for transaction:2023-008692
12/20/2023 M L Crose 3710, 3712, 3716, 3718 SW Maryville Pl LSMO Osage Lot 13 Clayton P 2023-6052 3rd Party Footing Inspection Report 11-18-21
12/20/2023 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/10/2024 Letter INSPECTION SUMMARY
01/11/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/14/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
11/20/2023 Permit Codes Residential Plan Review
11/20/2023 Approved Plans APPROVED TRUSS PACKAGE
11/20/2023 Approved Plans APPROVED TRUSS LAYOUT
11/20/2023 Plot Plan APPROVED PLOT PLAN
11/17/2023 Permit Codes Residential Plan Review
11/17/2023 Approved Plans APPROVED PLANS
11/15/2023 OS # 13 - PERMIT APP
04/03/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/12/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/17/2024 Receipt Receipt for transaction:2024-003593
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/17/2024 Receipt Receipt for transaction:2024-003633
05/30/2024 LOT 13 ASBUILT ROUGH
06/12/2024 Application Form OS #13 - TCO Extension Form 6_12_24
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/27/2024 Receipt Receipt for transaction:2024-005280
08/12/2024 Letter INSPECTION SUMMARY
08/12/2024 Letter INSPECTION SUMMARY
08/12/2024 Letter Codes 10 Day Letter
08/22/2024 OS 13 TCOExtension Request Form 8_22_24
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter Field Certificate of Occupancy
08/22/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home