Permit Application Status

PRRES20231955


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231955
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
05/02/2023
05/08/2023
03/04/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 246-6700  
SAVANNA@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 05/08/2023
Right of Way Permit Fee $85.00 $85.00 Paid 05/08/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/08/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 05/08/2023
Water Meter Fee $550.50 $550.50 Paid 05/08/2023
Valuation Fee New Single Family $1,061.27 $1,061.27 Paid 05/08/2023
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 01/02/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/01/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 5/31/2023 5/31/2023 05/31/2023
Miscellaneous Correction
Informational
05/31/2023
Plumber called in an under slab inspection to a duplex. This address is for a single family residence 2125 SE Rutherford Dr
Erosion Control Inspection Residential Failed 5/31/2023 05/31/2023
Misc
Corrective Action Required
05/31/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Water Service Inspection - R Passed 6/1/2023 (1:00) 6/1/2023 06/01/2023
Sewer Service Inspection - R Passed 6/1/2023 (1:00) 6/1/2023 06/01/2023
All Rough Inspection - Residential Failed 9/27/2023 9/27/2023 09/27/2023
Miscellaneous Correction
Corrective Action Required
09/27/2023
-SD cable in master bathroom needs a BOCA plate installed -Supply vents through the basement floor to the main level need to be sealed -Seal top and bottom plate penetrations at stairwell to garage
Gas Service Inspection - Residential Passed 9/27/2023 9/27/2023 09/27/2023
Electrical Service Inspection Passed 9/27/2023 9/27/2023 09/27/2023
Erosion Control Inspection Residential Failed 9/27/2023 09/27/2023
Misc
Corrective Action Required
05/31/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Miscellaneous Correction
Corrective Action Required
09/27/2023
Erosion control is missing along the east side of the property and the Southeast corner. Full erosion control must be maintained until full C of O
All Rough Inspection - Residential Passed 9/28/2023 9/28/2023 09/28/2023
Miscellaneous Correction
Resolved
09/28/2023
-SD cable in master bathroom needs a BOCA plate installed -Supply vents through the basement floor to the main level need to be sealed -Seal top and bottom plate penetrations at stairwell to garage
Driveway Inspection Partial 10/17/2023 10/17/2023 10/17/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A, DW is formed. Aggregate is compacted. Depth is in compliance. Must maintain under 2% through approach . Approves to pour.
Sidewalk Inspection Partial 10/17/2023 10/17/2023 10/17/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A. SW is formed and aggregate is compacted . lopes are in compliance. Approved to pour.
Driveway Inspection Passed 10/24/2023 10/24/2023 10/23/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A, DW is formed. Aggregate is compacted. Depth is in compliance. Must maintain under 2% through approach . Approves to pour. 10-23-23 DW is poured . Slopes are in compliance . Passed
Sidewalk Inspection Passed 10/24/2023 10/24/2023 10/23/2023
Misc
Informational
10/17/2023
10-17-23 Dustin A. SW is formed and aggregate is compacted . lopes are in compliance. Approved to pour. 10-23-23 Dustin A, SW is poured. Slopes are in compliance. Passed
Erosion Control Inspection Residential Failed 10/26/2023 10/26/2023
Misc
Corrective Action Required
09/27/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Miscellaneous Correction
Corrective Action Required
09/27/2023
Erosion control is missing along the east side of the property and the Southeast corner. Full erosion control must be maintained until full C of O
Miscellaneous Correction
Corrective Action Required
10/26/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy
Erosion Control Inspection Residential Failed 11/6/2023 11/06/2023
Misc
Corrective Action Required
10/26/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Miscellaneous Correction
Corrective Action Required
10/26/2023
Erosion control is missing along the east side of the property and the Southeast corner. Full erosion control must be maintained until full C of O
Miscellaneous Correction
Corrective Action Required
10/26/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy
Miscellaneous Correction
Corrective Action Required
11/06/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy. No further inspections will be completed until full erosion control is in place. 11/06/23 KBEARD
Footing Inspection - Residential Passed 12/7/2023 12/07/2023
Miscellaneous Correction
Informational
12/07/2023
Footing passed by a third party. No mention of piers in report
Occupancy Inspection - Codes Residential Failed 12/7/2023 12/7/2023 12/07/2023
Misc
Corrective Action Required
12/07/2023
- uncover manhole - Provide splash pads - Sump discharge to be 36” from foundation - Sod - Seal top of meter can - Provide handrail for stairs to basement - Uncover and activate all smoke detectors - There is to be no more than 3/8” variance in tread height in flight of stairs at basement stairs
Plot Plan Inspection Failed 12/7/2023 12/07/2023
Misc
Corrective Action Required
12/07/2023
Uncover manhole
Erosion Control Inspection Residential Failed 12/7/2023 12/07/2023
Misc
Corrective Action Required
11/06/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Miscellaneous Correction
Corrective Action Required
11/06/2023
Erosion control is missing along the east side of the property and the Southeast corner. Full erosion control must be maintained until full C of O
Miscellaneous Correction
Corrective Action Required
11/06/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy
Miscellaneous Correction
Corrective Action Required
11/06/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy. No further inspections will be completed until full erosion control is in place. 11/06/23 KBEARD
Misc
Corrective Action Required
12/07/2023
- MAINTAIN EROSION CONTROL UNTIL SOD IS IN PLACE
Occupancy Inspection - Codes Residential Failed 12/11/2023 12/11/2023 12/11/2023
Misc
Corrective Action Required
12/07/2023
- uncover covered manhole
Occupancy Inspection - Codes Residential Failed 12/18/2023 12/18/2023 12/18/2023
Misc
Corrective Action Required
12/11/2023
- uncover covered manhole (manhole still covered at North east corner of lot) Pay fees
Plot Plan Inspection Failed 12/18/2023 12/18/2023
Misc
Corrective Action Required
12/07/2023
Uncover manhole (manhole still covered at north east corner of lot)
Occupancy Inspection - Codes Residential Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Resolved
12/21/2023
- uncover covered manhole (manhole still covered at North east corner of lot) Pay fees
Miscellaneous Correction
Corrective Action Required
12/21/2023
2125 SW Rutherford. Occupancy -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -garage stair handrail is missing -Sod to siding in the front yard needs to have a clearance of 6 inches in height
Erosion Control Inspection Residential Passed 12/21/2023 12/21/2023
Misc
Resolved
12/21/2023
Erosion control in not installed and is required. Erosion control must be in place before calling in for the next inspection after under slab plumbing
Miscellaneous Correction
Resolved
12/21/2023
Erosion control is missing along the east side of the property and the Southeast corner. Full erosion control must be maintained until full C of O
Miscellaneous Correction
Resolved
12/21/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy
Miscellaneous Correction
Resolved
12/21/2023
Some erosion control is missing or torn down. Full erosion control must be maintained until occupancy. No further inspections will be completed until full erosion control is in place. 11/06/23 KBEARD
Misc
Resolved
12/21/2023
- MAINTAIN EROSION CONTROL UNTIL SOD IS IN PLACE
Occupancy Inspection - Codes Residential Failed 1/5/2024 1/5/2024 01/05/2024
Miscellaneous Correction
Resolved
01/05/2024
2125 SW Rutherford. Occupancy -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -garage stair handrail is missing -Sod to siding in the front yard needs to have a clearance of 6 inches in height
Miscellaneous Correction
Corrective Action Required
01/05/2024
2125 SW Rutherford. Occupancy (second inspection) -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -garage stair handrail is missing -Sod to siding in the front yard needs to have a clearance of 6 inches in height
Plot Plan Inspection Failed 1/5/2024 01/05/2024
Misc
Resolved
01/05/2024
Uncover manhole (manhole still covered at north east corner of lot)
Miscellaneous Correction
Corrective Action Required
01/05/2024
Sod to siding must have 6 inches of clearance
Occupancy Inspection - Codes Residential Ready for Temp CO 1/10/2024 1/10/2024 01/10/2024
Miscellaneous Correction
Resolved
01/10/2024
2125 SW Rutherford. Occupancy (second inspection) -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -garage stair handrail is missing
Miscellaneous Correction
Corrective Action Required
01/10/2024
Exterior sod to siding must have a 6 inch clearance (back patio area). Plot plan needs to pass after sod to siding area is in compliance. TCO passed only
Occupancy Inspection - Codes Residential Full C of O 3/4/2024 3/4/2024 03/04/2024
Miscellaneous Correction
Resolved
03/04/2024
Exterior sod to siding must have a 6 inch clearance (back patio area). Plot plan needs to pass after sod to siding area is in compliance. TCO passed only
Documents & Images
Date Uploaded File Type Document Name
05/02/2023 OS #70 Permit App
05/02/2023 OS #70
05/02/2023 70 osage roof layout
05/02/2023 ROOF SEALS
05/02/2023 LOT 70 FINAL 4-20-23
05/08/2023 Approved Plans APPROVED PLANS
05/08/2023 Approved Plans approved plot plan
05/08/2023 Approved Plans APPROVED TRUSS LAYOUT
05/08/2023 Approved Plans APPROVED TRUSS PACKAGE
05/08/2023 Permit Codes Residential Plan Review
05/08/2023 Permit Codes Residential Plan Review
05/08/2023 Permit DS Building Permit
05/08/2023 Permit DS Building Permit
05/08/2023 Receipt Receipt for transaction:2023-002891
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/26/2023 Letter INSPECTION SUMMARY
10/26/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
12/06/2023 OS-70 Footing Page 2
12/06/2023 OS-70 Footing Page 1
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/11/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
01/02/2024 Receipt Receipt for transaction:2024-000022
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/10/2024 Letter INSPECTION SUMMARY
01/29/2024 LOT 70 ASBUILT ROUGH
03/01/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/01/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/01/2024 Receipt Receipt for transaction:2024-001290
03/04/2024 Letter Codes Final Certificate of Occupancy
03/04/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home