Permit Application Status

PRRES20231596


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231596
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. SUSPENDED GARAGE SLAB. COVERED DECK. FINISHED/UNFINISHED BASEMENT.
04/12/2023
07/18/2023
01/07/2024
06/06/2024
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
JP Roberts, Address:4335 McGee St  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JPROBERTS23@HOTMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 07/18/2023
Water Meter Fee $680.46 $680.46 Paid 07/18/2023
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/18/2023
Right of Way Permit Fee $85.00 $85.00 Paid 07/18/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/18/2023
Valuation Fee New Single Family $2,777.29 $2,777.29 Paid 07/18/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 05/15/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/10/2023 (3:00) 8/10/2023 08/10/2023
Erosion Control Inspection Residential Partial 8/10/2023 08/10/2023
Misc
Corrective Action Required
08/10/2023
- Erosion control ok at this time
Foundation Inspection - Residential Passed 8/17/2023 08/17/2023
Erosion Control Inspection Residential Failed 8/30/2023 08/30/2023
Misc
Corrective Action Required
08/10/2023
- TRIM TALL VEGETATION - POST ADDRESS
Underslab Plumbing Inspection - Residential Passed 8/30/2023 8/30/2023 08/30/2023
Sewer Service Inspection - R Passed 9/12/2023 (1:00) 9/12/2023 09/12/2023
Water Service Inspection - R Passed 9/15/2023 (10:45) 9/15/2023 09/15/2023
Erosion Control Inspection Residential Partial 10/11/2023 10/11/2023
Misc
Corrective Action Required
08/30/2023
- In place at this time
All Rough Inspection - Residential Failed 10/11/2023 10/11/2023 10/11/2023
Misc
Corrective Action Required
10/11/2023
Corrective Action Required
10/11/2023
- Outside ok, inside provide 2" washers and nuts.
Gas Service Inspection - Residential Failed 2/15/2024 2/15/2024 02/15/2024
Misc
Corrective Action Required
02/15/2024
Complete fire place install for inspection
Electrical Service Inspection Failed 2/15/2024 2/15/2024 02/15/2024
Misc
Corrective Action Required
02/15/2024
Complete ufer ground bonding. (Bonding to remain accessible)
All Rough Inspection - Residential Failed 2/15/2024 2/15/2024 02/15/2024
Misc
Corrective Action Required
02/15/2024
POST ADDRESS MAINTAIN EROSION CONTROL -bottom plate penetrations in powder room and porch door on this side -Fire block bottom plate penetrations SW corner rod living room -missing stud in stud pack under beam living room /kitchen -secure bolts at beam above living room /kitchen -fire block laundry wall into kitchen ceiling space -bottom plate penetration at primary bedroom entrance -fire block primary bedroom wall space to ceiling space -missing stud pack for beam at primary bedroom/closet entry -update plans to show attic storage space above primary bedroom closet -seal all top and bottom plate penetrations in pantry -add hangers for floor joist cut for plumbing above bed 2 -seal all bottom plate penetrations in bed 2 -porch and patios covered could not inspect -seal penetrations in carriage house 2nd floor -missing cripple studs at 2nd floor slider header -add joist hangers at 2nd floor stairwell ceiling -home office closet seal top plate penetrations -secure SE cable in furr down in basement -address holes drilled for pex in joist closer than 2” to each other above bed 3 -fire block plumbing into furr down bed 3 exterior wall -seal penetrations in RA joist space above bed 4 -missing lvl above garage plans call for 3 (you have 2) -upload 3rd party suspended slab inspection -complete ufer bond. Ufer bond to remain accessible -seal all top and bottom plate penetrations not listed -
Gas Service Inspection - Residential Passed 2/20/2024 2/20/2024 02/20/2024
Misc
Resolved
02/20/2024
Complete fire place install for inspection
Electrical Service Inspection Passed 2/20/2024 2/20/2024 02/20/2024
Misc
Resolved
02/20/2024
Complete ufer ground bonding. (Bonding to remain accessible)
All Rough Inspection - Residential Failed 2/20/2024 2/20/2024 02/20/2024
Misc
Corrective Action Required
02/15/2024
-update plans to show attic storage space above primary bedroom closet -porch and patios covered could not inspect -address holes drilled for pex in joist closer than 2” to each other above bed 3 -missing lvl above garage plans call for 3 (you have 2) -upload 3rd party suspended slab inspection OK TO INSULATE
Suspended Slab Inspection Passed 2/29/2024 02/29/2024
Misc
Informational
02/29/2024
-INSPECTION PERFORMED BY THIRD PARTY ( EVERSTEAD) FOR FRONT STOOPS (2)
All Rough Inspection - Residential Passed 2/29/2024 2/29/2024 02/29/2024
Misc
Resolved
02/29/2024
-address holes drilled for pex in joist closer than 2” to each other above bed 3
Occupancy Inspection - Codes Residential Failed 5/9/2024 5/9/2024 05/09/2024
Misc
Corrective Action Required
05/09/2024
- Post permanent address - Open electrical box at front porch - Final grading and sod - Provide guard and handrail for stairs at garage - Provide hardware on sliding door at kitchen - Secure CSST within 12” of appliance at second floor Mechanical room - Install secondary locks on second floor sliding door - Handrail of stairs to upstairs does not extend to bottom riser - Ladder of Egress window over 18” to grade - Protect electrical panel from DWV above - Label all non- GFCI outlets - Install smoke detector in basement at furnace - Provide anti siphon device at main water spigot - Seal all exterior penetrations
Erosion Control Inspection Residential Partial 5/9/2024 05/09/2024
Misc
Corrective Action Required
10/11/2023
- In place at this time
Plot Plan Inspection Passed 5/9/2024 05/09/2024
Erosion Control Inspection Residential Partial 5/15/2024 05/15/2024
Misc
Corrective Action Required
05/09/2024
- In place at this time, currently grading
Occupancy Inspection - Codes Residential Ready for Temp CO 5/15/2024 5/15/2024 05/15/2024
Misc
Corrective Action Required
05/09/2024
- Final grading and sod - Check step off front pourch to grade when grading complete - Seal all exterior penetrations
Erosion Control Inspection Residential Passed 6/6/2024 06/06/2024
Misc
Resolved
06/06/2024
- In place at this time, currently grading
Occupancy Inspection - Codes Residential Full C of O 6/6/2024 6/6/2024 06/06/2024
Misc
Resolved
06/06/2024
Documents & Images
Date Uploaded File Type Document Name
04/12/2023 1121 SW Corinthian Pl_ Permit Application
04/12/2023 1121 SW Corintihain Pl_ Excise Tax Application
05/18/2023 Permit Codes Residential Plan Review
07/10/2023 Permit Codes Residential Plan Review
07/11/2023 Permit Codes Residential Plan Review
07/13/2023 Plot Plan APPROVED PLOT PLAN
07/13/2023 Approved Plans APPROVED PLANS
07/18/2023 Permit Codes Residential Plan Review
07/18/2023 Permit DS Building Permit
07/18/2023 Receipt Receipt for transaction:2023-005565
08/10/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/17/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
09/12/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
02/15/2024 Letter INSPECTION SUMMARY
02/15/2024 Letter INSPECTION SUMMARY
02/15/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/29/2024 124 Pergola Park Stoop Slabs
02/29/2024 Approved Plans APPROVED UPDATED PLANS A2-A3
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/15/2024 Receipt Receipt for transaction:2024-003457
06/06/2024 Letter Codes Final Certificate of Occupancy
06/06/2024 Letter Field Certificate of Occupancy
06/06/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home