Summary
PRRES20231589
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX. UNFINISHED BASEMENT. ROOF TRUSSES.
04/12/2023
05/02/2023
10/18/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 434-5074 Ext:321  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,585.56 $2,585.56 Paid 05/02/2023
Water Tap Fee $7,460.00 $7,460.00 Paid 05/02/2023
Water Meter Fee $1,101.00 $1,101.00 Paid 05/02/2023
Sanitary Sewer Development Fee $2,768.00 $2,768.00 Paid 05/02/2023
Right of Way Permit Fee $85.00 $85.00 Paid 05/02/2023
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 05/02/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 08/30/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 08/30/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 09/15/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/22/2023 05/22/2023
Misc
Informational
05/22/2023
Footing was passed by a third party. Piers were not mentioned in footing inspection by the third party.
Sewer Service Inspection - R Partial 5/26/2023 (1:00) 5/26/2023 05/26/2023
Miscellaneous Correction
Informational
05/26/2023
-2133 sewer passed -2135 sewer will be called in at another date This will be a partial inspection only
Sewer Service Inspection - R Passed 5/30/2023 (1:00) 5/30/2023 05/30/2023
Miscellaneous Correction
Resolved
05/30/2023
-2133 sewer passed -2135 sewer will be called in at another date This will be a partial inspection only
Underslab Plumbing Inspection - Residential Passed 6/1/2023 6/1/2023 06/01/2023
Erosion Control Inspection Residential Failed 6/1/2023 06/01/2023
Misc
Corrective Action Required
06/01/2023
Erosion control is not installed at underground plumbing inspection. Perimeter erosion control needs to be completed before any more inspection can be conducted.
Water Service Inspection - R Passed 6/1/2023 (1:00) 6/1/2023 06/01/2023
Misc
Informational
06/01/2023
- Both 2123 and 2125 passed
Erosion Control Inspection Residential Partial 7/7/2023 07/07/2023
Misc
Resolved
07/07/2023
Erosion control is not installed at underground plumbing inspection. Perimeter erosion control needs to be completed before any more inspection can be conducted.
Misc
Informational
07/07/2023
Erosion control is in place. 07/07/2023
All Rough Inspection - Residential Not Ready 7/7/2023 7/7/2023 07/07/2023
Miscellaneous Correction
Corrective Action Required
07/07/2023
All MEP contractors must be finished before an all rough inspection can be conducted, this includes calling in or scheduling a rated assembly. The electrical contractor was still working in one side of the duplex. Time: 11:07 AM. KBEARD
Rated Assembly Inspection Passed 7/10/2023 7/10/2023 07/10/2023
All Rough Inspection - Residential Failed 7/10/2023 7/10/2023 07/10/2023
Miscellaneous Correction
Resolved
07/10/2023
All MEP contractors must be finished before an all rough inspection can be conducted, this includes calling in or scheduling a rated assembly. The electrical contractor was still working in one side of the duplex. Time: 11:07 AM. KBEARD
Miscellaneous Correction
Corrective Action Required
07/10/2023
2135 - Add stud next to cantilevered through beam in garage - Shims needed at dining room window jack studs - Stud shoes needed in the master bathroom - A/c supply air in up stairs needs to not be squeezed for proper air flow - Joist bracket in basement not nailed off properly - Gas gage at furnace is not working 2133 - Garage anchor bolts need to be in the middle 1/3 bottom plate - Hole in A/c supply line in garage and needs to be braced every 10 feet - Hole in main living room chase needs to be covered - Stud is loose in upstairs chase - Stud shoes needed in master bathroom wall - UFER rod needs to be accessible - Electrical panel needs to be grounded
Electrical Service Inspection Passed 7/10/2023 7/10/2023 07/10/2023
Gas Service Inspection - Residential Passed 7/10/2023 7/10/2023 07/10/2023
All Rough Inspection - Residential Passed 7/11/2023 7/11/2023 07/11/2023
Miscellaneous Correction
Resolved
07/11/2023
2135 - Add stud next to cantilevered through beam in garage - Shims needed at dining room window jack studs - Stud shoes needed in the master bathroom - A/c supply air in up stairs needs to not be squeezed for proper air flow - Joist bracket in basement not nailed off properly - Gas gage at furnace is not working 2133 - Garage anchor bolts need to be in the middle 1/3 bottom plate - Hole in A/c supply line in garage and needs to be braced every 10 feet - Hole in main living room chase needs to be covered - Stud is loose in upstairs chase - Stud shoes needed in master bathroom wall - UFER rod needs to be accessible - Electrical panel needs to be grounded
Erosion Control Inspection Residential Partial 7/11/2023 07/11/2023
Misc
Informational
07/07/2023
Erosion control is in place. 07/11/2023
Occupancy Inspection - Codes Residential Not Ready 8/21/2023 8/21/2023 08/21/2023
Miscellaneous Correction
Corrective Action Required
08/21/2023
2135 - Kitchen faucet not installed - Kitchen backsplash electrical outlet not installed - Garage to house door is missing hardware to close - Back patio flood light not installed - Master bathroom shower is not completed This is not a complete list. This duplex is not ready for an occupancy inspection and should have not been scheduled. Walk your property and make sure it is ready before scheduling an inspection! 08/21/2023 KBEARD 8:20AM
Driveway Inspection Passed 8/7/2023 8/7/2023 08/23/2023
Misc
Informational
08/02/2023
8-2-23 BR Driveway is formed up and aggregate is place and compacted. Ready for concrete. 8-23-23 BR Driveway is constructed to LS specification
Sidewalk Inspection Passed 8/7/2023 8/7/2023 08/23/2023
Misc
Informational
08/02/2023
8-2-23 BR Sideway is formed up and aggregate is place and compacted. Ready for concrete. 8-23-23 BR Sideway is constructed to LS specification
Occupancy Inspection - Codes Residential Failed 8/24/2023 8/24/2023 08/24/2023
Miscellaneous Correction
Resolved
08/24/2023
2135 - Kitchen faucet not installed - Kitchen backsplash electrical outlet not installed - Garage to house door is missing hardware to close - Back patio flood light not installed - Master bathroom shower is not completed This is not a complete list. This duplex is not ready for an occupancy inspection and should have not been scheduled. Walk your property and make sure it is ready before scheduling an inspection! 08/21/2023 KBEARD 8:20AM
Miscellaneous Correction
Corrective Action Required
08/24/2023
2133 second occupancy inspection - Front porch is required to have a guard rail installed because is has over a 30 inch drop off to the side yard - Kitchen sink/dishwasher hot water line needs a anti hammer device installed - Utility room faucets need anti hammer devices installed - Sod, splash pads and sump pump extension is not installed - Grading is not completed 2135 - Kitchen sink/dishwasher hot water line needs a anti hammer device installed - Back porch to house concrete steps have a variance of more than the allowed 3/8 of an inch in riser height difference - Garage to house door self closing hinge does not work properly - Vertical boards above the interior garage door must be sealed at the ceiling - Main water supply line does not have a anti siphon valve installed - First step up at the upstairs stairwell is over the the required riser height of 7 3/4 inches - Master bathroom shower is missing it’s plumbing fixtures and tile - Utility room is missing the anti water hammer devices - Sod, splash pads and sump pump extension is not installed - Exterior sump pump extension is not sealed - Grading is not completed PAY ALL FEES associated with this permit
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Misc
Informational
07/11/2023
Erosion control is in place. 07/11/2023
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is not in place. Full erosion control must be maintained until full CO
Occupancy Inspection - Codes Residential Failed 9/5/2023 9/5/2023 09/05/2023
Miscellaneous Correction
Corrective Action Required
08/24/2023
2133 third occupancy inspection - Front porch is required to have a guard rail installed because is has over a 30 inch drop off to the side yard - Sod, splash pads and sump pump extension is not installed - Grading is not completed 2135 - Vertical boards above the interior garage door must be sealed at the ceiling - First step up at the upstairs stairwell is over the maximum 2 percent horizontal slope - Sod, splash pads and sump pump extension is not installed - Exterior sump pump extension is not sealed - Grading is not completed PAY ALL FEES associated with this permit if any
Occupancy Inspection - Codes Residential Ready for Temp CO 9/12/2023 9/12/2023 09/12/2023
Miscellaneous Correction
Corrective Action Required
09/05/2023
2133 - Sod, splash pads and sump pump extension is not installed - Grading is not completed 2135 - Sod, splash pads and sump pump extension is not installed - Grading is not completed
Erosion Control Inspection Residential Partial 9/12/2023 09/12/2023
Misc
Informational
08/29/2023
Erosion control is in place. 07/11/2023
Miscellaneous Correction
Resolved
09/12/2023
Erosion control is not in place. Full erosion control must be maintained until full CO
Miscellaneous Correction
Informational
09/12/2023
Erosion control is in place at the time of TCO inspection 09/12/23
Erosion Control Inspection Residential Passed 10/13/2023 10/13/2023
Misc
Informational
09/12/2023
Erosion control is in place. 07/11/2023
Miscellaneous Correction
Informational
09/12/2023
Erosion control is in place at the time of TCO inspection 09/12/23
Plot Plan Inspection Failed 10/13/2023 10/13/2023
Miscellaneous Correction
Corrective Action Required
10/13/2023
Submit an as graded plot plan
Occupancy Inspection - Codes Residential Failed 10/13/2023 10/13/2023 10/13/2023
Miscellaneous Correction
Resolved
10/13/2023
2133 - Sod, splash pads and sump pump extension is not installed - Grading is not completed 2135 - Sod, splash pads and sump pump extension is not installed - Grading is not completed
Miscellaneous Correction
Corrective Action Required
10/13/2023
Submit a as graded plot plan to be reviewed before a Full C of O can be issued. On site plot does not match the original city approved plot plan.
Plot Plan Inspection Passed 10/18/2023 10/18/2023
Miscellaneous Correction
Resolved
10/18/2023
Submit an as graded plot plan
Occupancy Inspection - Codes Residential Full C of O 10/18/2023 10/18/2023
Miscellaneous Correction
Resolved
10/18/2023
Submit a as graded plot plan to be reviewed before a Full C of O can be issued. On site plot does not match the original city approved plot plan.
Documents & Images
Date Uploaded File Type Document Name
04/12/2023 54 OSAGE ROOF LAYOUT
04/12/2023 ROOF SEALS
04/12/2023 OS #54 - PERMIT APP
04/17/2023 Approved Plans APPROVED PLANS
04/17/2023 Permit Codes Residential Plan Review
04/17/2023 Permit Codes Residential Plan Review
04/20/2023 Approved Plans APPROVED TRUSS LAYOUT
04/20/2023 Approved Plans APPROVED TRUSS PACKAGE
04/20/2023 Permit Codes Residential Plan Review
04/20/2023 Permit Codes Residential Plan Review
04/25/2023 Permit Codes Residential Plan Review
04/25/2023 Permit Codes Residential Plan Review
05/02/2023 Plot Plan APPROVED PLOT PLAN
05/02/2023 Permit Codes Residential Plan Review
05/02/2023 Permit Codes Residential Plan Review
05/02/2023 Permit DS Building Permit
05/02/2023 Permit DS Building Permit
05/02/2023 Receipt Receipt for transaction:2023-002655
05/22/2023 M L Crose 2133 & 2135 SW Osage Dr LSMO Footing Inspection Report 5-18-23
05/22/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/26/2023 Letter INSPECTION SUMMARY
05/26/2023 Letter INSPECTION SUMMARY
05/26/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/30/2023 Receipt Receipt for transaction:2023-006732
09/01/2023 LOT 55 ASBUILT
09/05/2023 Letter INSPECTION SUMMARY
09/12/2023 Letter INSPECTION SUMMARY
09/15/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/15/2023 Receipt Receipt for transaction:2023-007076
10/13/2023 Letter INSPECTION SUMMARY
10/13/2023 Letter INSPECTION SUMMARY
10/13/2023 Letter INSPECTION SUMMARY
10/17/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
10/18/2023 Letter INSPECTION SUMMARY
10/18/2023 Letter Codes Final Certificate of Occupancy
10/18/2023 Letter Field Certificate of Occupancy
01/29/2024 Plot Plan approved as graded plot plan
01/29/2024 Plot Plan approved as graded plot plan
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents