Permit Application Status

PRRES20220524


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220524
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. PARTIALLY COVERED DECK. ROOF TRUSSES.
02/10/2022
02/17/2022
08/14/2022
04/27/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/17/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/17/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/17/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/17/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/17/2022
9110078-Valuation Fee New Single Family $986.58 $986.58 Paid 02/17/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 04/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 3/23/2022 3/23/2022 03/23/2022
Sewer Service Inspection - R Passed 4/6/2022 (11:15) 4/6/2022 04/06/2022
Water Service Inspection - R Passed 4/12/2022 (9:45) 4/12/2022 04/12/2022
Electrical Service Inspection Passed 10/13/2022 10/13/2022
Gas Service Inspection - Residential Passed 10/13/2022 10/13/2022
All Rough Inspection - Residential Failed 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
10/13/2022
-have engineer address condition of wood trusses that are greyed, water damage that were exposed to weather on ground for multiple months -address broken truss garage above attic access -provide H2.5 hold downs at girder truss garage -no top plate corner lap at front entry exterior wall -solid block all sheathing breaks -address overbored joists for DWV at basement -anchor bolts within 12” of sill plate break basement -support plumbing east side basement -floor drain for furnace condensate at basement
Footing Inspection - Residential Passed 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
10/13/2022
FOOTING APPROVED PER DAVID P AINSWORTH 3/1/22
All Rough Inspection - Residential Failed 10/18/2022 10/18/2022 10/18/2022
Misc
Corrective Action Required
10/13/2022
-have engineer address condition of wood trusses that are greyed, sun/water damage that were exposed to weather on ground for multiple month - (LETTER NEEDS TO BE FROM ENGINEER AND NEEDS TO BE SPECIFIC FOR ADDRESS/PERMIT)
All Rough Inspection - Residential Failed 10/20/2022 10/20/2022 10/20/2022
Misc
Corrective Action Required
10/18/2022
-have engineer address condition of wood trusses that are greyed, sun/water damage that were exposed to weather on ground for multiple month - (LETTER NEEDS TO BE FROM ENGINEER AND NEEDS TO BE SPECIFIC FOR ADDRESS/PERMIT)
Misc
Corrective Action Required
10/20/2022
10/20/22 - CLEAN TRUSSES PER ENGINEER LETTER ADDRESS TRUSS CONNECTION PLATES WITH TRUSS ENGINEER PER ENGINEER LETTER SUBMITTED "Truss near rear wall of garage shows separation at connection plate" "Have truss engineer prescribe field issue fix for any connector plates that are not fully embedded."
Driveway Inspection Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/21/2022
On Friday, 10-21-2022, I performed and passed a driveway for placement of concrete.
Piers/Caissons Inspection - Residential Partial 10/21/2022 (9:45) 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/21/2022
Patial, 3 more piers needed - 1 pier, pad j on North East for roof load.
All Rough Inspection - Residential Passed 10/25/2022 10/25/2022 10/25/2022
Misc
Resolved
10/25/2022
-have engineer address condition of wood trusses that are greyed, sun/water damage that were exposed to weather on ground for multiple month - (LETTER NEEDS TO BE FROM ENGINEER AND NEEDS TO BE SPECIFIC FOR ADDRESS/PERMIT)
Misc
Resolved
10/25/2022
10/20/22 - CLEAN TRUSSES PER ENGINEER LETTER ADDRESS TRUSS CONNECTION PLATES WITH TRUSS ENGINEER PER ENGINEER LETTER SUBMITTED "Truss near rear wall of garage shows separation at connection plate" "Have truss engineer prescribe field issue fix for any connector plates that are not fully embedded."
Piers/Caissons Inspection - Residential Passed 4/11/2023 04/11/2023
Misc
Resolved
04/11/2023
Patial, 3 more piers needed - 1 pier, pad j on North East for roof load.
Erosion Control Inspection Residential Failed 4/11/2023 04/11/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 4/18/2023 4/18/2023 04/18/2023
Miscellaneous Correction
Corrective Action Required
04/18/2023
-garage to house door self closing hinge not fully closing -HWT breaker needs a lock out installed -garage attic access panel is not installed -interior 2x6 garage board needs to be sealed at the top -sump pump needs to say non GFCI -back patio post beams to rim joist need 2 1/2 inch through bolts in each one -address back patio post to corner of covered patio connection -splash blocks and sod -sump pump extension to 36 inches from foundation -AC whip needs to be secured -top of AC disconnect needs to be sealed -driveway exterior lights need to be self sealed since they are less than 8 feet off the ground -permit for irrigation needs to be obtained
Occupancy Inspection - Codes Residential Full C of O 4/27/2023 4/27/2023 04/27/2023
Miscellaneous Correction
Resolved
04/27/2023
-permit for irrigation needs to be obtained
Documents & Images
Date Uploaded File Type Document Name
02/10/2022 CB #157 - PERMIT APPLICATION
02/15/2022 Permit Codes Residential Plan Review
02/15/2022 Plot Plan APPROVED PLOT PLAN
02/15/2022 Approved Plans APPROVED DRAWINGS
02/15/2022 Approved Plans APPROVED TRUSS PACKAGE
02/16/2022 Approved Plans APPROVED TRUSS LAYOUT
02/16/2022 Permit Codes Residential Plan Review
02/17/2022 Permit DS Building Permit
02/17/2022 Receipt Receipt for transaction:2022-000863
03/02/2022 M L Crose 3530 SW Corbin Rd LSMO Cobey Creek Lot 157 Clayton Permit 2022-0524 Footing Inspection Report 3-1-22
03/02/2022 M L Crose 3530 SE Corbin Rd LSMO Cobey Creek Lot 157 Clayton Permit 2022-0524 Footing Inspection Report with Address Correccted 3-1-22
03/23/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter APPROVED TRUSS LETTER
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/17/2022 Approved Plans APPROVED TRUSS LETTER
10/17/2022 BFS CB Weathered Letter
10/18/2022 Letter INSPECTION SUMMARY
10/20/2022 157 Cobey Creek truss exposure letter
10/20/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 3008835 C3 REP 10212022
10/21/2022 Letter APPROVED TRUSS LETTER
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 157 Cobey Creek truss exposure letter rev 10-20-22
10/25/2022 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/17/2023 Receipt Receipt for transaction:2023-002136
04/18/2023 Letter INSPECTION SUMMARY
04/27/2023 Letter Field Certificate of Occupancy
04/27/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home