Summary
PRRES20220226
Building Permit - Residential
Certificate of Occupancy
RUSH CREEK LLC
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - ENG. FLOOR SYSTEM (DEF)- ROOF TRUSSES (DEF) - LOT IS IN FLOOD PLAIN - COVERED AND UNCOVERED DECK STOP WORK ORDER generated on 04/18/2022 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/20/2022 12:00 AM by username 'Patrick Schonfeldt'.
01/18/2022
01/26/2022
07/20/2022
09/27/2023
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
RUSH CREEK LLC, Address:4609 SW RAINTREE DR  
JP Roberts, Address:4335 McGee St  
JPROBERTS23@HOTMAIL.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 01/26/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/26/2022
8331507-Sewer Connection Fee $330.00 $330.00 Paid 01/26/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 01/26/2022
Water Meter Fee $479.24 $479.24 Paid 01/26/2022
Valuation Fee New Single Family $1,566.40 $1,566.40 Paid 01/26/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 08/17/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 08/17/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 08/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 4/18/2022 4/18/2022 04/18/2022
Misc
Corrective Action Required
04/18/2022
INSPECTION DENIED -FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed - Stop Work 4/18/2022 4/18/2022 04/18/2022
Misc
Corrective Action Required
04/18/2022
-FOOTING POURED WITHOUT INSPECTION- ENGINEER REPORT REQUIRED TO BE UPLOADED WITHIN 48 HOURS OF INSPECTION STOP WORK ISSUED
Footing Inspection - Residential Passed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/18/2022
APPROVED PER BRADLEY HUXOL 3/2/22
Underslab Plumbing Inspection - Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/18/2022
7-919 INSTALL INTERIOR DRAIN TILE
Erosion Control Inspection Residential Partial 4/25/2022 4/25/2022 04/25/2022
Underslab Plumbing Inspection - Residential Passed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
Erosion Control Inspection Residential Partial 4/28/2022 4/28/2022 04/28/2022
Water Service Inspection - R Passed 7/27/2022 (8:45) 7/27/2022 07/27/2022
Electrical Service Inspection Failed 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
10/26/2022
NO INSPECTION NO CITY STAMPED PLANS ON SITE AT INSPECTION
Gas Service Inspection - Residential Failed 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
10/26/2022
NO INSPECTION NO CITY STAMPED PLANS ON SITE AT INSPECTION
All Rough Inspection - Residential Not Ready 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
10/26/2022
NO INSPECTION NO CITY STAMPED PLANS ON SITE AT INSPECTION
Electrical Service Inspection Passed 10/27/2022 10/27/2022 10/27/2022
Misc
Resolved
10/27/2022
NO INSPECTION NO CITY STAMPED PLANS ON SITE AT INSPECTION
Gas Service Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/26/2022
-gas pressure 0 psi
All Rough Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/26/2022
-fireblock deadspace at kitchen wall, pantry -seal bottom plate penetrations at kitchen -fireblock deadspace at great room -secure all vertical DWV 2” or less at mid point -provide protection plates at DWV stud penetrations master water closet -complete vent line master bath attic, cut out for can light -min 24” lap between dbl top plate break - see master bed -complete elevator shaft wall and fireblock -solid block all sheathing breaks, nail all zip board exterior sheathing to blocking per plans -complete framing for dumbwaiter with truss flooring modifications complete, have mitek engineer letter in site at reinspection -fur down for mechanical at storage room basement -move romex off outside of stud at basement bath, bore and run through top plate and secure -nail protection plate at NM romex wet bar basement den -seal top plate penetrations at basement den -min 24” lap between dbl top plate see basement den and basement den closet -provide pressure regulator at water line -secure main water line pex to stud -support DWV every 48” oc -gas pressure 0 psi
Gas Service Inspection - Residential Passed 11/8/2022 11/8/2022 11/08/2022
Misc
Resolved
11/08/2022
All Rough Inspection - Residential Failed 11/8/2022 11/8/2022 11/08/2022
Misc
Corrective Action Required
10/27/2022
-provide protection plates at DWV stud penetrations master water closet -complete vent line master bath attic, cut out for can light -min 24” lap between dbl top plate break - see master bed -complete elevator shaft wall and fireblock, fireblock at attic and fireblock between studs at basement top plate -solid block all sheathing breaks, nail all zip board exterior sheathing to blocking per plan -complete framing for dumbwaiter with truss flooring modifications complete, have mitek engineer letter in site at reinspection -fur down for mechanical at storage room basement (fireblock vertical to horizontal at the soffit end) -seal penetrations at basement bath -nail protection plate at NM romex wet bar basement den -secure main water line pex to stud -support DWV every 48” oc, traps not considered support
All Rough Inspection - Residential Failed 11/11/2022 11/11/2022 11/11/2022
Misc
Corrective Action Required
11/08/2022
-complete framing for dumbwaiter with truss flooring modifications complete, have mitek engineer letter in site at reinspection, upload engineer letter to portal, seal electrical penetration at plate and secure electrical wire **OK TO INSULATE**
All Rough Inspection - Residential Passed 11/21/2022 11/21/2022 11/21/2022
Misc
Resolved
11/21/2022
-complete framing for dumbwaiter with truss flooring modifications complete, have mitek engineer letter in site at reinspection, upload engineer letter to portal, seal electrical penetration at plate and secure electrical wire **OK TO INSULATE**
Occupancy Inspection - Codes Residential Failed 4/20/2023 4/20/2023 04/20/2023
Miscellaneous Correction
Corrective Action Required
04/20/2023
-stairs do not meet code on riser height -elevator power whips need to be secured to the wall -basement kitchen has two outlets that need to be GFCI protected -basement kitchen cooktop junction box needs to be secured -basement bathroom fixtures not completed -cooktop needs a lock out installed on the breaker -garage walkout porch light needs to be of a sealed porch light -kitchen hood vent is not installed -garage to house door needs a self closing hinge installed -sod and splash guards not installed -driveway and sidewalks not installed
Occupancy Inspection - Codes Residential Failed 5/1/2023 5/1/2023 05/01/2023
Miscellaneous Correction
Corrective Action Required
04/20/2023
-basement cook top needs a vent installed -basement bathroom fixtures not completed -kitchen hood vent is not installed -garage to house door needs a self closing hinge installed -sod and splash guards not installed -driveway and sidewalks not installed
Occupancy Inspection - Codes Residential Failed 5/11/2023 5/11/2023 05/11/2023
Miscellaneous Correction
Corrective Action Required
05/01/2023
-sod and splash guards not installed -driveway not installed. Driveway needs to be installed before a TCO can be issued
Driveway Inspection Partial 5/22/2023 5/22/2023 05/22/2023
Misc
Informational
05/22/2023
5-22-23 PS Driveway approach and curb pre pour approved, ok to pour
Occupancy Inspection - Codes Residential Temporary C of O 5/23/2023 5/23/2023 05/23/2023
Miscellaneous Correction
Informational
05/23/2023
-sod and splash guards not installed and are needed for a full C of O
Driveway Inspection Passed 5/26/2023 5/26/2023 05/26/2023
Misc
Informational
05/22/2023
5-22-23 PS Driveway approach and curb pre pour approved, ok to pour 5-26-23 PS Driveway meets LS specifications
Occupancy Inspection - Codes Residential Ready for Temp CO 6/23/2023 06/23/2023
Miscellaneous Correction
Informational
05/23/2023
-sod and splash guards not installed and are needed for a full C of O
Misc
Informational
06/23/2023
Sod and splash blocks are still not installed. Pay all fees if any. 06/23/2023 K Beard
Occupancy Inspection - Codes Residential Temporary C of O 7/24/2023 07/24/2023
Miscellaneous Correction
Informational
06/23/2023
-sod and splash guards not installed and are needed for a full C of O
Misc
Informational
06/23/2023
Sod and splash blocks are still not installed. Pay all fees if any. 06/23/2023 K Beard
Miscellaneous Correction
Informational
07/24/2023
Sod and splash blocks are still not installed. Pay all fees if any. 07/24/2023 K Beard
Occupancy Inspection - Codes Residential Failed 9/20/2023 09/20/2023
Miscellaneous Correction
Informational
07/24/2023
-sod and splash guards not installed and are needed for a full C of O
Misc
Informational
07/24/2023
Sod and splash blocks are still not installed. Pay all fees if any. 06/23/2023 K Beard
Miscellaneous Correction
Informational
07/24/2023
Sod and splash blocks are still not installed. Pay all fees if any. 07/24/2023 K Beard
Occupancy Inspection - Codes Residential Full C of O 9/27/2023 09/27/2023
Miscellaneous Correction
Resolved
09/27/2023
-sod and splash guards not installed and are needed for a full C of O
Misc
Resolved
09/27/2023
Sod and splash blocks are still not installed. Pay all fees if any. 06/23/2023 K Beard
Miscellaneous Correction
Resolved
09/27/2023
Sod and splash blocks are still not installed. Pay all fees if any. 07/24/2023 K Beard
Plot Plan Inspection Passed 9/27/2023 09/27/2023
Erosion Control Inspection Residential Passed 9/27/2023 09/27/2023
Documents & Images
Date Uploaded File Type Document Name
01/18/2022 4871 SW Raintree Parkway Building Permit
01/18/2022 4871 SW Raintree Parkway Excise Tax Application
01/21/2022 Permit Codes Residential Plan Review
01/26/2022 Approved Plans APPROVED PLANS
01/26/2022 Approved Plans APPROVED PLOT PLAN
01/26/2022 Permit Codes Residential Plan Review
01/26/2022 Permit DS Building Permit
01/26/2022 Receipt Receipt for transaction:2022-000470
04/18/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter Stop Work Order
04/19/2022 1 Rush Creek at Raintree FDTN
04/19/2022 1 Rush Creek at Raintree FTNG
04/20/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/11/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
04/10/2023 Letter Codes 140 Day Letter
04/20/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/23/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/26/2023 Letter INSPECTION SUMMARY
07/24/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/17/2023 Receipt Receipt for transaction:2023-006371
09/20/2023 Letter Codes 10 Day Letter
09/27/2023 Letter Codes Final Certificate of Occupancy
09/27/2023 Letter Field Certificate of Occupancy
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home