Permit Application Status

PRRES20220073


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220073
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - UNCOVERED DECK
01/06/2022
01/19/2022
07/06/2022
09/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $857.24 $857.24 Paid 01/19/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/19/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/19/2022
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/19/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/19/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/19/2022
9110078-Valuation Fee New Single Family $49.63 $49.63 Paid 03/09/2022
$906.87
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 05/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/15/2022 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
APPROVED PER DAVID P AINSWORTH 1/26/22
Erosion Control Inspection Residential Partial 2/15/2022 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Passed 2/16/2022 2/16/2022 02/16/2022
Erosion Control Inspection Residential Partial 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sewer Service Inspection - R Passed 2/25/2022 (10:00) 2/25/2022 02/25/2022
Water Service Inspection - R Passed 3/9/2022 (8:45) 3/9/2022 03/09/2022
Erosion Control Inspection Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Resolved
03/09/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/09/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Gas Service Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/07/2022
-complete all gas lines -pressure test required -gas line bond required
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/07/2022
-nail exterior sheathing garage portal PFH per plans -nail all exterior sheathing per plans -security blocking at garage man door -fireblock at beam pocket beneath rim joist right side of dbl car bay -top plate to top plate corner connection as required by code east corner laundry exterior wall meeting garage wall -min 24” offset between dbl top plate breaks, strap plates- see master shower, great room , garage -provide bocca protection plate for DWV bottom plate master shower -secure strap all vertical DWV 2” or less at mid point -address (1) ply of trpl girder trusses at master bedroom corner supported by smart siding furring strip -Fireblock all tub traps -fireblock seal around HVAC penetration at attic fireblock front bath HVAC chase -seal unused top plate penetration master bedroom -provide full bearing for dbl beam for front covered porch at front bedroom and garage load points -provide security blocking at front door -solid block all sheathing breaks -submit revised plans for approval that include garage man door -(2) 2x4 trimmer studs at garage entry door per plans -exterior bracing CS-PF at great room windows per plans, (2) 2x12 header cont corner to corner, tension strap capacity/length and exterior sheathing nailing per plans/IRC R602.10.6.4 -(4) 2x4 stud packs at all girder trusses bearing ends per plans -min 16” oc stud spacing for walls with LIB bracing -Have engineer with truss manufacturer address the C2 and C3 trusses above foyer that have been cut to modify size -all truss hangers per plans -all truss lateral bracing per plans -fireblock top plate penetrations at east corner basement near stairs -support DWV every 48” oc -fireblock vertical every 10’ between studs and foundation/framing at finished basement -fireblock gaps in fireblock material between top plates and top plate foundation -provide protection plate pex top plate basement den -fur down for bath exhaust duct at basement bed closet -provide protection plate top plate for pex basement bathroom -complete all plumbing -complete all gas lines -pressure test required -gas line bond required
Erosion Control Inspection Residential Partial 4/7/2022 4/7/2022 04/07/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/07/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
04/07/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/07/2022
-nail exterior sheathing garage portal PFH per plans -nail all exterior sheathing per plans -top plate to top plate corner connection as required by code east corner laundry exterior wall meeting garage wall, (nail off strap) -min 24” offset between dbl top plate breaks, strap plates- see master shower, great room , garage -exterior bracing CS-PF at great room windows per plans, nail exterior sheathing per plans/engineer letter, nail off tension straps, IRC R602.10.6.4 -(4) 2x4 stud packs at all girder trusses bearing ends per plans, great room -min 16” oc stud spacing for walls with LIB bracing, studs need to be full height to top plate -Have engineer with truss manufacturer address the C2 and C3 trusses above foyer that have been cut to modify size -land all electrical to boxes removed for corrections at walls -all truss hangers per plans -all truss lateral bracing per plans -fireblock vertical to horizontal furred down soffit end basement closet -support Ward flex gas to joist through furred down basement den, min 3” clearance to nailing surface
Gas Service Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/07/2022
-Gas pressure must maintain 10 psi for test
All Rough Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/12/2022
-nail all exterior sheathing per plans -exterior bracing CS-PF at great room windows per plans, nail exterior sheathing per plans/engineer letter, remove trim and nail sheathing to header, leave trim off above window for reinspection, IRC R602.10.6.4 ok to insulate and rock
Erosion Control Inspection Residential Partial 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/07/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Misc
Resolved
04/21/2022
Gas Service Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Misc
Resolved
04/21/2022
Erosion Control Inspection Residential Partial 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/15/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Driveway Inspection Passed 5/2/2022 5/2/2022 05/02/2022
Misc
Informational
05/02/2022
On Monday, 5-02-2022, I performed and passed driveway Inspection for concrete placement.
Piers/Caissons Inspection - Residential Failed 5/18/2022 (10:00) 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/18/2022
-MIN 36" PIER DEPTH FOR FROST DEPTH -MIN 18" WIDE PIERS PER PLANS, ENSURE 18" MIN CONT PIER, PIERS BELLED
Piers/Caissons Inspection - Residential Passed 5/19/2022 (8:00) 5/19/2022 05/19/2022
Misc
Resolved
05/19/2022
Occupancy Inspection - Codes Residential Failed 5/27/2022 5/27/2022 05/27/2022
Miscellaneous Correction
Corrective Action Required
05/27/2022
- provide address - Obtain an irrigation permit and submit a back flow certification - Final grading and sod - Complete down spouts - Splash blocks - Driveway inspection pending - Provide landing for deck stairs - Outlet cover missing in basement - Label non GFCI outlet in basement - Seal top of meter can and A/C disconnect - Seal all exterior penetrations - Secure A/C whip 12” from disconnect -
Plot Plan Inspection Passed 5/31/2022 05/31/2022
Driveway Inspection Passed 6/1/2022 6/1/2022 06/01/2022
Misc
Informational
06/01/2022
On Wednesday 6.1.2022 I conducted a post-pour driveway inspection and pass it for compliance with City Standards - DJ
Occupancy Inspection - Codes Residential Temporary C of O 6/2/2022 6/2/2022 06/02/2022
Miscellaneous Correction
Corrective Action Required
05/27/2022
- sod - Splash blocks - Provide landing for deck stairs - Seal all exterior penetrations **OK FOR TCO, TCO EXPIRES 6/30/22**
Erosion Control Inspection Residential Partial 06/02/2022
Misc
Corrective Action Required
04/21/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Temporary C of O 6/30/2022 06/30/2022
Miscellaneous Correction
Corrective Action Required
06/02/2022
- sod - Splash blocks - Provide landing for deck stairs - Seal all exterior penetrations **OK FOR TCO, TCO EXTENED AT BUILDER/HOMEOWNER REQUEST FOR SOD PLACEMENT TCO EXPIRES 9/30/22
Occupancy Inspection - Codes Residential Full C of O 9/23/2022 9/23/2022 09/23/2022
Miscellaneous Correction
Resolved
09/23/2022
Erosion Control Inspection Residential Passed 9/23/2022 9/23/2022 09/23/2022
Misc
Resolved
09/23/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Documents & Images
Date Uploaded File Type Document Name
01/06/2022 CB #156 - PERMIT APPLICATION
01/07/2022 Permit Codes Residential Plan Review
01/10/2022 Approved Plans Approved Drawings
01/10/2022 Approved Plans Approved Truss Layout
01/10/2022 Approved Plans Approved Truss Package
01/19/2022 Plot Plan Approved Plot Plan
01/19/2022 Permit Codes Residential Plan Review
01/19/2022 Permit DS Building Permit
01/19/2022 Receipt Receipt for transaction:2022-000318
02/14/2022 M L Crose 3534 SE Corbin Dr LSMO Cobey Creek Lot 156 Clayton Permit 2022-0073 Footing Inspection Footing 1-26-22
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
03/09/2022 CB #156 - Scope of Work Statement Application
03/09/2022 Approved Plans Approved Finished Basement Plan
03/09/2022 Receipt Receipt for transaction:2022-001258
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Approved Plans Approved Revised Sheet A4
04/11/2022 156 cobey creek letter for header
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Approved Plans Approved Truss Repair
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/26/2022 Receipt Receipt for transaction:2022-003996
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Plot Plan Approved As Graded Plot Plan
05/31/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter Codes Temporary Certificate of Occupancy
06/02/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter Codes Temporary Certificate of Occupancy
06/30/2022 Email 3534 SE Corbin Dr - TCO Extension
09/23/2022 Letter Field Certificate of Occupancy
09/23/2022 Letter Codes Final Certificate of Occupancy
09/23/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home