Permit Application Status

PRRES20215946


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215946
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. ENGINEERED FLOOR SYSTEM- DEFERRED. FINISHED/UNFINISHED BASEMENT.
11/12/2021
12/20/2021
06/08/2022
12/14/2022
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
GLEN@elevatedesignbuildkc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/20/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/20/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/20/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/20/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/20/2021
9110078-Valuation Fee New Single Family $1,122.66 $1,122.66 Paid 12/20/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/21/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/28/2022 01/28/2022
Misc
Informational
01/28/2022
third party inspection performed
Sewer Service Inspection - R Partial 2/10/2022 (10:45) 2/10/2022 02/10/2022
Sewer Service Inspection - R Passed 2/10/2022 02/10/2022
Water Service Inspection - R Passed 2/11/2022 (1:00) 2/11/2022 02/11/2022
Underslab Plumbing Inspection - Residential Passed 2/14/2022 2/14/2022 02/14/2022
Erosion Control Inspection Residential Failed 2/14/2022 2/14/2022 02/14/2022
Misc
Corrective Action Required
02/14/2022
-Repair Downed silt fence -maintain gravel filter
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/14/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Electrical Service Inspection Failed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
06/02/2022
Complete all electrical for inspection to be performed.
Gas Service Inspection - Residential Passed 6/2/2022 6/2/2022 06/02/2022
All Rough Inspection - Residential Failed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
06/02/2022
-pfh anchor bolts to be in the middle 1/3 of sill plate -nail guard for electrical at pfh -address rafter to ceiling joist connection and rafters landing on blocks throughout -mid way strap all dwv 2” in diameter of less -land all electrical at back patio area -uncover covered patio to inspect rafter to ceiling joist connection -fire block to ceiling space right and left of fire place -seal gaps in fire blocking at fireplace -missing nails in hangers above master -provide proper slope to dwv above master bath -strike plates for electrical in basement office -vertical to horizontal fire blocking every ten feet in basement. (Family room N windows) -fire block furr down end in bed 3 closet -provide support for dwv above basement bath and bed 3/4 support every 48” OC -provide opening to bed 4 closet
All Rough Inspection - Residential Not Ready 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/02/2022
-address rafter to ceiling joist connection and rafters landing on blocks throughout -mid way strap all dwv 2” in diameter of less -land all electrical at back patio area -uncover covered patio to inspect rafter to ceiling joist connection -fire block to ceiling space right and left of fire place -seal gaps in fire blocking at fire place -provide proper slope to dwv above master bath (provide proper support -strike plates for electrical in basement office some still missing -fire block furr down end in bed 3 closet(if using Unfaced insulation it must be packed tightly and securely)
Electrical Service Inspection Passed 6/16/2022 6/16/2022 06/16/2022
Misc
Resolved
06/16/2022
Complete all electrical for inspection to be performed.
All Rough Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/23/2022
-land all electrical at back patio -fire block furr down end in bed 3 closet(if using Unfaced insulation it must be packed tightly and securely)
All Rough Inspection - Residential Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Resolved
06/23/2022
-land all electrical at back patio -fire block furr down end in bed 3 closet(if using Unfaced insulation it must be packed tightly and securely)
Sidewalk Inspection Passed 7/14/2022 7/14/2022 07/19/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete 7.19.2022 Sidewalk appears to be in compliance
Driveway Inspection Passed 7/13/2022 7/13/2022 07/19/2022
Misc
Informational
07/13/2022
On 7.13.2022 I conducted a driveway inspection and pass the concrete to pour concrete. 7.19.2022 Driveway appears to be in compliance
Sidewalk Inspection Passed 8/12/2022 8/12/2022 08/12/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete 8.12.2022 Sidewalk appears to be compliant
Driveway Inspection Passed 8/12/2022 8/12/2022 08/12/2022
Misc
Informational
07/13/2022
On 7.13.2022 I conducted a driveway inspection and pass the concrete to pour concrete. 8.12.2022 Driveway appears to be compliant
Sidewalk Inspection Partial 10/17/2022 10/17/2022 10/17/2022
Misc
Informational
10/17/2022
10-17-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Sidewalk Inspection Passed 10/24/2022 10/24/2022 10/24/2022
Misc
Informational
10/17/2022
10-17-22 RH. Sidewalk is formed up and aggregate is placed and compacted. 10-24-22 RH. Sidewalk meets LS and ADA specification.
Plot Plan Inspection Passed 11/18/2022 11/18/2022
Piers/Caissons Inspection - Residential Passed 11/18/2022 11/18/2022
Erosion Control Inspection Residential Passed 11/18/2022 11/18/2022
Misc
Resolved
11/18/2022
-Repair Downed silt fence -maintain gravel filter
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 11/18/2022 11/18/2022 11/18/2022
Misc
Corrective Action Required
11/18/2022
-provide fire protection for engineered I joist in unfinished spaces -lock out on breaker for hardwired appliances in kitchen -GFCI for dishwasher outlet -secure A/c whip with-in 12" of disconnect -seal all exterior penetrations Mitchell Schwarz 11/18/2022 3:39 PM
Occupancy Inspection - Codes Residential Full C of O 12/14/2022 12/14/2022 12/14/2022
Misc
Resolved
12/14/2022
-provide fire protection for engineered I joist in unfinished spaces -lock out on breaker for hardwired appliances in kitchen -GFCI for dishwasher outlet -secure A/c whip with-in 12" of disconnect -seal all exterior penetrations Mitchell Schwarz 11/18/2022 3:39 PM
Documents & Images
Date Uploaded File Type Document Name
11/15/2021 Application Form License Tax Application
11/15/2021 21-11-15- HF 084 - Review Comment Response
11/16/2021 Application Form APPLICATION
11/18/2021 Permit Codes Residential Plan Review
12/07/2021 Review Comment Response
12/07/2021 PP-21-12-03-HF084-revised
12/10/2021 Approved Plans APPROVED DRAWINGS
12/10/2021 Permit Codes Residential Plan Review
12/14/2021 Review Comment Response
12/14/2021 Plot Plan APPROVED PLOT PLAN
12/14/2021 Permit Codes Residential Plan Review
12/20/2021 Permit DS Building Permit
12/20/2021 Receipt Receipt for transaction:2021-009381
01/11/2022 Approved Plans APPROVED PIER PLAN
01/20/2022 2112 SW Harvest Moon Ln_PIER INSP_2022-01-18
01/27/2022 84 Hook Farms FTNG
01/28/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/07/2022 84 Hook Farms - Framing
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/21/2022 Receipt Receipt for transaction:2022-004918
06/21/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/24/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter Field Certificate of Occupancy
12/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home