Permit Application Status

PRRES20215762


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215762
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED STOOP IN THE REAR
11/03/2021
11/09/2021
05/07/2022
11/17/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,066.58 $1,066.58 Paid 11/09/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/09/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/09/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/09/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/09/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/09/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/22/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/15/2021 (11:30) 12/15/2021 12/15/2021
Underslab Plumbing Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Sewer Service Inspection - R Passed 2/8/2022 (2:00) 2/8/2022 02/08/2022
Water Service Inspection - R Passed 2/10/2022 (10:45) 2/10/2022 02/10/2022
Erosion Control Inspection Residential Failed 2/10/2022 2/10/2022 02/10/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/30/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER MAINTAIN GUTTER BUDDYS AT CURB INLETS & REMOVE SEDIMENT BUILD UP
All Rough Inspection - Residential Not Ready 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Electrical Service Inspection Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Gas Service Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
Electrical Service Inspection Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/21/2022
-top plate structural straps required to have min (4) 10D nails each side of strap, not screws -follow fastener requirements per manufacturer of stud shoes, not screws -provide (4) 2X stud packs at all girder truss bearing point, see plans for locations -CS-PF portal design per plans at master bed windows, see IRC R602.10.6.4/plans for reference, min (2) 2x12 header, tension straps, nail all exterior sheathing per design -all truss hangers per plans at garage -provide H2.5 truss hold down clips all trusses at covered patio and front porch -provide all truss lateral bracing per plans -fireblock annular space around DWV at furred down soffit end basement bed closet -b vent at furnace, maintain 1” clearance from combustibles, secure NM off vent -solid block between joists every 48” oc for kitchen island per plans
Electrical Service Inspection Passed 6/24/2022 6/24/2022 06/24/2022
Misc
Resolved
06/24/2022
Gas Service Inspection - Residential Passed 6/24/2022 6/24/2022 06/24/2022
Misc
Resolved
06/24/2022
All Rough Inspection - Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/21/2022
-top plate structural straps required to have min (4) 10D nails each side of strap, not screws -follow fastener requirements per manufacturer of stud shoes, not screws -provide (4) 2X stud packs at all girder truss bearing point, see plans for locations -CS-PF portal design per plans at master bed windows, see IRC R602.10.6.4/plans for reference, min (2) 2x12 header, tension straps, nail all exterior sheathing per design -all truss hangers per plans at garage -provide H2.5 truss hold down clips all trusses at covered patio and front porch -provide all truss lateral bracing per plans -fireblock annular space around DWV at furred down soffit end basement bed closet -b vent at furnace, maintain 1” clearance from combustibles, secure NM off vent -solid block between joists every 48” oc for kitchen island per plans
Erosion Control Inspection Residential Partial 06/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/24/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER MAINTAIN GUTTER BUDDYS AT CURB INLETS & REMOVE SEDIMENT BUILD UP
All Rough Inspection - Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
06/24/2022
Inspection denied no city stamped plans in home. Plans in box outside to wet to use. -top plate structural straps required to have min (4) 10D nails each side of strap, not screws -follow fastener requirements per manufacturer of stud shoes, not screws -provide (4) 2X stud packs at all girder truss bearing point, see plans for locations -CS-PF portal design per plans at master bed windows, see IRC R602.10.6.4/plans for reference, min (2) 2x12 header, tension straps, nail all exterior sheathing per design -all truss hangers per plans at garage -provide H2.5 truss hold down clips all trusses at covered patio and front porch -provide all truss lateral bracing per plans -fireblock annular space around DWV at furred down soffit end basement bed closet -b vent at furnace, maintain 1” clearance from combustibles, secure NM off vent -solid block between joists every 48” oc for kitchen island per plans
All Rough Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
Erosion Control Inspection Residential Passed 7/22/2022 7/22/2022 07/22/2022
Driveway Inspection Partial 8/8/2022 8/8/2022 08/08/2022
Misc
Informational
08/08/2022
8-8-22 RH. Driveway was formed up and aggregate placed and compacted.
Sidewalk Inspection Partial 8/8/2022 8/8/2022 08/08/2022
Misc
Informational
08/08/2022
8-8-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Driveway Inspection Failed 8/15/2022 8/15/2022 08/12/2022
Misc
Informational
08/08/2022
8-8-22 RH. Driveway was formed up and aggregate placed and compacted. 8-12-22 RH. Driveway was poured and covered the sanitary sewer MH 58-064. This will need to be located and uncovered.
Sidewalk Inspection Partial 8/15/2022 8/15/2022 08/12/2022
Misc
Informational
08/08/2022
8-8-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 8-12-22 RH. Currently sidewalk passes ADA and LS specification but with the driveway being replaced due to Sanity sewer MH being poured over that could need a reinspection.
Erosion Control Inspection Residential Passed 11/15/2022 11/15/2022 11/15/2022
Occupancy Inspection - Codes Residential Failed 11/15/2022 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
-final driveway and sidewalk inspections required, contact development services to schedule -submit as graded plot plan for review and approval
Plot Plan Inspection Passed 11/16/2022 11/16/2022
Driveway Inspection Passed 11/16/2022 11/16/2022 11/16/2022
Misc
Informational
08/12/2022
8-8-22 RH. Driveway was formed up and aggregate placed and compacted. 8-12-22 RH. Driveway was poured and covered the sanitary sewer MH 58-064. This will need to be located and uncovered.
Misc
Informational
11/16/2022
On Wednesday, 11-16-2022 I performed and passed a visual inspection for the adjustment completed for the Man hole located and adjusted completed.
Occupancy Inspection - Codes Residential Full C of O 11/17/2022 11/17/2022 11/17/2022
Misc
Resolved
11/17/2022
Documents & Images
Date Uploaded File Type Document Name
11/03/2021 CB #1 - PERMIT APPLICATION
11/08/2021 Permit Codes Residential Plan Review
11/08/2021 Approved Plans Approved Drawings
11/08/2021 Approved Plans Approved Truss Layout
11/08/2021 Approved Plans Approved Truss Pacakge
11/09/2021 Permit Codes Residential Plan Review
11/09/2021 Permit DS Building Permit
11/09/2021 Receipt Receipt for transaction:2021-008608
11/10/2021 LOT 1 FINAL 11-10-21
11/10/2021 Approved Plans Approved Plot Plan
11/12/2021 Approved Plans Approved Revised Drawings
12/15/2021 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/22/2022 Receipt Receipt for transaction:2022-004978
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
07/11/2022 CB 1 - Engineering Letter - Solid Block Floor Joists Under Island
07/11/2022 Strong-Drive® SDWC TRUSS PT3
07/15/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Plot Plan Approved As-Graded Plot Plan
11/16/2022 Letter INSPECTION SUMMARY
11/16/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter Field Certificate of Occupancy
11/17/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home