Permit Application Status

PRRES20215423


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215423
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
10/18/2021
11/02/2021
04/16/2022
08/10/2022
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
SARA@ELEVATEDESIGNBUILDKC.COM  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
CENTRAL PLUMBING HTG & A/C INC, Address:P O BOX 218, Phone:(816) 942-6355  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/02/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/02/2021
9110078-Valuation Fee New Single Family $860.91 $860.91 Paid 11/02/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/02/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/02/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/08/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/08/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/08/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/15/2021 12/15/2021
Misc
Informational
12/15/2021
-3rd party inspection -ground rod located where indicated on 3rd party inspection.
Underslab Plumbing Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Misc
Corrective Action Required
12/15/2021
-interior drain tile required
Sewer Service Inspection - R Passed 12/15/2021 12/15/2021
Underslab Plumbing Inspection - Residential Passed 12/16/2021 12/16/2021
Water Service Inspection - R Passed 12/16/2021 (1:30) 12/16/2021 12/16/2021
Piers/Caissons Inspection - Residential Passed 1/10/2022 01/10/2022
Misc
Informational
01/10/2022
3rd party inspection performed
Gas Service Inspection - Residential Passed 3/17/2022 3/17/2022 03/17/2022
Electrical Service Inspection Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
Connect ufer ground to middle grounded bus bar
All Rough Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
-nail all intersecting wall corners 12” OC -seal hole in floor Along west wall kitchen area -land electrical at back deck area -protect NM at kitchen east wall -Fire block dead space at laundry -protect NM With in 6’ of attic access -complete bath fan exhausts in master bathroom -Provide engineer address for non-continuous studs at gable wall of living room -have engineer address walls taller than 12’ must be a minimum 2x6 -add support for stair entry landing and basement wall double joist -install all windows and doors -complete water lines at NW corner garage -secure water line in mechanical room -panning for RA in furr down above furnace not complete -complete basement bath exhaust -seal around block above bed 4 entry stud bay used to close off joist spaces used for return air -seal penetrations into soffit above service panel -connect the ufer ground to the middle grounded bus bar -solid block sheathing break in Rec room S wall -nail off joist hanger near bed 4 in Rec room
All Rough Inspection - Residential Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/17/2022
-nail all intersecting wall corners 12” OC -seal hole in floor Along west wall kitchen area -land electrical at back deck area -protect NM at kitchen east wall -Fire block dead space at laundry -protect NM With in 6’ of attic access -complete bath fan exhausts in master bathroom -Provide engineer address for non-continuous studs at gable wall of living room -have engineer address walls taller than 12’ must be a minimum 2x6 -add support for stair entry landing and basement wall double joist -install all windows and doors -complete water lines at NW corner garage -secure water line in mechanical room -panning for RA in furr down above furnace not complete -complete basement bath exhaust -seal around block above bed 4 entry stud bay used to close off joist spaces used for return air -seal penetrations into soffit above service panel -connect the ufer ground to the middle grounded bus bar -solid block sheathing break in Rec room S wall -nail off joist hanger near bed 4 in Rec room
Misc
Corrective Action Required
04/06/2022
Provide access to front stoop for entry, for inspection.
Electrical Service Inspection Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/17/2022
Connect ufer ground to middle grounded bus bar
Misc
Corrective Action Required
04/06/2022
Provide access to front door for entry, for inspection.
All Rough Inspection - Residential Not Ready 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/06/2022
-nail all intersecting wall corners 12” OC -seal hole in floor Along west wall kitchen area -land electrical at back deck area -protect NM at kitchen east wall -Fire block dead space at laundry -protect NM With in 6’ of attic access -complete bath fan exhausts in master bathroom -Provide engineer address for non-continuous studs at gable wall of living room -have engineer address walls taller than 12’ must be a minimum 2x6 -add support for stair entry landing and basement wall double joist -install all windows and doors -complete water lines at NW corner garage -secure water line in mechanical room -panning for RA in furr down above furnace not complete -complete basement bath exhaust -seal around block above bed 4 entry stud bay used to close off joist spaces used for return air -seal penetrations into soffit above service panel -connect the ufer ground to the middle grounded bus bar -solid block sheathing break in Rec room S wall -nail off joist hanger near bed 4 in Rec room
Misc
Corrective Action Required
04/06/2022
Provide access to front stoop for entry, for inspection. back fill the front porch for access or ope garage doors. inspeciton denied.
Corrective Action Required
04/07/2022
Electrical Service Inspection Passed 4/13/2022 4/13/2022 04/13/2022
Misc
Resolved
04/13/2022
Connect ufer ground to middle grounded bus bar
Misc
Resolved
04/13/2022
Provide access to front door for entry, for inspection.
All Rough Inspection - Residential Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/07/2022
-protect NM With in 6’ of attic access -install all windows and doors
All Rough Inspection - Residential Not Ready 4/18/2022 4/18/2022 04/18/2022
Misc
Corrective Action Required
04/13/2022
-protect NM With in 6’ of attic access
All Rough Inspection - Residential Passed 4/19/2022 4/19/2022 04/19/2022
Misc
Resolved
04/19/2022
-protect NM With in 6’ of attic access
Piers/Caissons Inspection - Residential Passed 4/27/2022 04/27/2022
Driveway Inspection Partial 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
On 5.9.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Occupancy Inspection - Codes Residential Not Ready 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/28/2022
Inspection denied no address in place and no erosion control. Mitchell Schwarz 07/28/2022 10:26 AM
Erosion Control Inspection Residential Failed 7/28/2022 07/28/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
07/28/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Failed 8/4/2022 8/4/2022 08/04/2022
Misc
Resolved
08/04/2022
Inspection denied no address in place and no erosion control. Mitchell Schwarz 07/28/2022 10:26 AM
Misc
Corrective Action Required
08/04/2022
-provide illumination for address -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -provide hand rail to basement -pressure relief valve like to close to ground -flood lamp at rear of home -spark rings at back splash’s in kitchen and prep where required by code -address pending driveway inspection -pay all fees -obtain lawn irrigation permit -provide as graded plot plan.
Driveway Inspection Passed 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
05/09/2022
On 5.9.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 8.9.2022 Driveway appears to be compliant
Erosion Control Inspection Residential Passed 8/9/2022 08/09/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
08/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Resolved
08/09/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Ready for Temp CO 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
08/04/2022
TCO UNTIL 9/9/22 -pay TCO fee -address pending driveway inspection -provide as graded plot plan
Plot Plan Inspection Passed 8/10/2022 08/10/2022
Occupancy Inspection - Codes Residential Full C of O 8/10/2022 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
TCO UNTIL 9/9/22 -pay TCO fee -address pending driveway inspection -provide as graded plot plan
Documents & Images
Date Uploaded File Type Document Name
10/18/2021 License_Tax_Application_leesummit
10/18/2021 Residental Permit Application Word
10/18/2021 Permit Codes Residential Plan Review
10/28/2021 Approved Plans approved plans
10/28/2021 Approved Plans APPROVED PLOT PLAN
10/28/2021 Permit Codes Residential Plan Review
11/02/2021 Permit DS Building Permit
11/02/2021 Receipt Receipt for transaction:2021-008416
12/15/2021 20 Hook Farms FTNG (1)
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
01/10/2022 Final_2021_12_23_DPier_LSOM_Pat Cochran Concrete
01/10/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
04/05/2022 2026 SW Hook Farm Drive_Framing Evaluation Report_4-5-22[22519]
04/06/2022 2026 SW Hook Farm Drive_Framing Evaluation Report_4-5-22
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/08/2022 Receipt Receipt for transaction:2022-006495
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter Codes Final Certificate of Occupancy
08/10/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home