Summary
PRRES20214831
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 12/13/2021 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 12/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
09/15/2021
09/17/2021
12/15/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,593.38 $1,593.38 Paid 09/17/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/17/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/17/2021
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 09/17/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 09/17/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/17/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Footing Inspection - Residential Failed - Stop Work 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
ADDRESS FOOTING POURED WITHOUT INSPECTION.
Footing Inspection - Residential Passed 12/14/2021 12/14/2021 12/14/2021
Misc
Informational
12/14/2021
APPROVED PER BRADLEY HUXOL 10/22/21
Underslab Plumbing Inspection - Residential Not Ready 12/15/2021 12/15/2021 12/15/2021
Misc
Resolved
12/15/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Misc
Corrective Action Required
12/15/2021
INTERIOR DRAIN TILE NEEDS TO BE RAN
Sewer Service Inspection - R Passed 12/30/2021 12/30/2021
Water Service Inspection - R Passed 1/5/2022 (8:00) 1/5/2022 01/05/2022
Underslab Plumbing Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
INTERIOR DRAIN TILE NEEDS TO BE RAN
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/08/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
Electrical Service Inspection Passed 6/13/2022 6/13/2022 06/13/2022
Gas Service Inspection - Residential Passed 6/13/2022 6/13/2022 06/13/2022
All Rough Inspection - Residential Failed 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
06/13/2022
-nail all exterior sheathing per plans -provide anchor bolts garage PFH -provide exterior sheathing west garage exterior wall -provide joist hanger at trpl joist garage -fireblock HVAC/plumbing chase garage -provide joist hanger at trpl joist 1st floor powder bath -bocca plate DWV 1st floor powder bath -provide stud shoe 1st floor powder bath exterior wall -provide dbl joist hanger 1st floor bedroom -stud shoes at kitchen DWV exterior wall -nail off all joist hangers throughout -provide joist hangers at floor joists foyer and great room -install front door -LIB x bracing all locations per plans -Provide 3” SCH 40 steel column at (3) 9 1/4” lvl foyer per plans -provide full bearing or joist hanger at dbl 2x10 at stair wall foyer -provide bocca plate pex water lines bottom plate dining room -seal top plate electrical penetration dining room -C7 truss garage not landing on top plate per plans, H2.5 missing -truss hanger covered porch per plans -Provide H2.5 truss hold down clips at front covered porch -Have engineer with truss manufacturer address B2 truss at covered porch that has been modified and cut down -nail off strap embedded in concrete at front porch -2x6 wall corner studs should be full height to top plate, see NE corner stair wall -(4) 2X stud picks at all girder truss bearing ends per plans, continue bearing with stud packs from 2nd floor to 1st floor for load transfer per plans -min 24” offset between dbl top plate breaks - see bed#4 -CS-PF exterior bracing per plans 2nd floor front bedroom, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 -provide electrical for jacuzzi tub master bedroom -provide stud shoe at master bath exterior stud DWV -provide structural straps at all top plates bored 50% or more all exterior walls and interior load bearing walls, strap required to be min 16 gauge, extend 6” passed opening each side with min (4) 10D nails each side of strap -provide bocca protection plate DWV top plate bath#3 -provide clearance/strike plates at ward flex gas line vertical run along stud at 1st floor bedroom per ward flex manufacturer installation instructions
All Rough Inspection - Residential Failed 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
06/13/2022
-LIB x bracing all locations per plans (NOT CORRECT DESIGN GARAGE, 10’ WALL IS 69” LIB SEE PLANS) -C7 truss garage not landing on top plate per plans, H2.5 missing (THE TRUSS IS BEARING ON USED CONCRETE FORM LUMBER WHICH IS NOT ALLOWED) -CS-PF exterior bracing per plans 2nd floor front bedroom, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 (CANNOT INSPECT NAIL PATTERN OF SHEATHING WITH LAP SIDING INSTALLED) -provide clearance/strike plates at ward flex gas line vertical run along stud at 1st floor bedroom per ward flex manufacturer installation instructions
Erosion Control Inspection Residential Failed 8/2/2022 08/02/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/02/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain gravel filter
All Rough Inspection - Residential Passed 8/2/2022 8/2/2022 08/02/2022
Misc
Resolved
08/02/2022
-LIB x bracing all locations per plans (NOT CORRECT DESIGN GARAGE, 10’ WALL IS 69” LIB SEE PLANS) -C7 truss garage not landing on top plate per plans, H2.5 missing (THE TRUSS IS BEARING ON USED CONCRETE FORM LUMBER WHICH IS NOT ALLlowed) -CS-PF exterior bracing per plans 2nd floor front bedroom, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 (CANNOT INSPECT NAIL PATTERN OF SHEATHING WITH LAP SIDING INSTALLED) -provide clearance/strike plates at ward flex gas line vertical run along stud at 1st floor bedroom per ward flex manufacturer installation instructions
Driveway Inspection Passed 8/19/2022 8/19/2022 08/17/2022
Misc
Informational
08/15/2022
8.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete 8.17.2022 Driveway appears to be compliant
Sidewalk Inspection Partial 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/18/2022
8.18.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Passed 8/25/2022 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
8-25-22 RH. Sidewalk meets LS and ADA Specification.
Driveway Inspection Passed 8/15/2022 8/15/2022 08/25/2022
Misc
Informational
08/15/2022
8.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete 8-25-22 RH. Driveway meets LS and ADA Specification.
Erosion Control Inspection Residential Passed 11/21/2022 11/21/2022 11/21/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/21/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain gravel filter
Occupancy Inspection - Codes Residential Failed 11/21/2022 11/21/2022 11/21/2022
Misc
Corrective Action Required
11/21/2022
-post permanent address numbers -provide as graded plot plan -pay outstanding fees -guardrail required at front porch -install front door hardware -repair rock at garage ceiling -provide handrail garage stairs -no more than 3/8” variance between garage stair rises -garage door must self closing -repair rock at 2nd floor bath vanity outlet -remove access cover at jacuzzi tub master bath for inspection -support DWV 3” line at basement behind water heater -provide ladder at basement egress window -splash blocks, min 36” discharge from foundation -Sump pump 36” discharge from foundation
Plot Plan Inspection Passed 12/8/2022 12/08/2022
Occupancy Inspection - Codes Residential Failed 12/14/2022 12/14/2022 12/14/2022
Misc
Corrective Action Required
11/21/2022
-color of address numbers must contrast against background color on house -pay outstanding fees -GFCI protection required at outlet jacuzzi tub motor master bath
Occupancy Inspection - Codes Residential Full C of O 12/15/2022 12/15/2022 12/15/2022
Misc
Resolved
12/15/2022
Documents & Images
Date Uploaded File Type Document Name
09/15/2021 RR #71 - PERMIT APP
09/15/2021 Approved Plans Approved Drawings
09/16/2021 Approved Plans Approved Truss Layout
09/16/2021 Approved Plans Approved Truss Package
09/16/2021 Plot Plan Approved Plot Plan
09/16/2021 Permit Codes Residential Plan Review
09/17/2021 Permit DS Building Permit
09/17/2021 Receipt Receipt for transaction:2021-007397
12/13/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter Stop Work Order
12/13/2021 71 Reserve at Stoney Creek-FTNG
12/13/2021 71 Reserve at Stoney Creek-FDTN
12/14/2021 Letter Stop Work Order
12/14/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/20/2022 Approved Plans Approved Revised Beam Drawing
03/08/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/23/2022 Approved Plans Approved Truss Repair
07/20/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
12/07/2022 LOT 71 ASBUILT
12/08/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
12/08/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
12/14/2022 Receipt Receipt for transaction:2022-009509
12/15/2022 Letter Field Certificate of Occupancy
12/15/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home