Summary
PRRES20214264
Building Permit - Residential
Certificate of Occupancy
BEHOME LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINIHSED BASEMENT - COVERED DECK - RETAINING WALL ( NEED TO PROVIDE PLANS OR AN ENGINEER REPORT IN ORDER TO APPROVED ) STOP WORK ORDER generated on 08/25/2021 12:00 AM by username 'Nick Lightner'. STOP WORK ORDER removed on 10/07/2021 12:00 AM by username 'Adam Nacke'.
08/16/2021
10/07/2021
02/13/2022
12/02/2022
Locations
Contacts
BE HOME LLC, Address:7618 S ARNETT RD, Phone:(816) 591-6013  
BEHOME LLC, Address:7618 S ARNETT RD  
Michael Powell, Address:1101 SW US 40 Highway, Phone:(816) 591-6013  
MIKE@BEHOMELLC.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/04/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/04/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/04/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/04/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/04/2021
9110078-Valuation Fee New Single Family $945.04 $945.04 Paid 10/04/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed - Stop Work 8/25/2021 8/25/2021 08/25/2021
Misc
Corrective Action Required
08/25/2021
8/25/21 15:30 - Erosion control needs to be put into place due to no vegetation and runoff.
Erosion Control Inspection Residential Passed 10/7/2021 10/7/2021 10/07/2021
Misc
Resolved
10/07/2021
8/25/21 15:30 - Erosion control needs to be put into place due to no vegetation and runoff.
Misc
Informational
10/07/2021
10-7-21 1:46 AN Erosion control issue has been fixed
Underslab Plumbing Inspection - Residential Failed 10/11/2021 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/11/2021
**INSPECTION DENIED. POST ADDRESS
Underslab Plumbing Inspection - Residential Failed 10/15/2021 10/15/2021 10/15/2021
Misc
Corrective Action Required
10/11/2021
**INSPECTION FAILED. THE SUBMITTED PLAN DOES NOT MATCH ANYTHING TO THE HOUSE BEING CONSTRUCTED. RESUBMIT THE CORRECT PLAN TO THE CITY FOR APPROVAL
Underslab Plumbing Inspection - Residential Passed 10/27/2021 10/27/2021 10/27/2021
Misc
Resolved
10/27/2021
**INSPECTION FAILED. THE SUBMITTED PLAN DOES NOT MATCH ANYTHING TO THE HOUSE BEING CONSTRUCTED. RESUBMIT THE CORRECT PLAN TO THE CITY FOR APPROVAL
Sewer Service Inspection - R Failed 11/2/2021 (2:30) 11/2/2021 11/02/2021
Misc
Corrective Action Required
11/02/2021
-PROVIDE A SLEEVE AT SEWER PENETRATION OF FOUNDATION WALL -PROVIDE GRAVEL SUPPORT FOR SEWER
Sewer Service Inspection - R Passed 11/3/2021 (1:00) 11/3/2021 11/03/2021
Misc
Resolved
11/03/2021
-PROVIDE A SLEEVE AT SEWER PENETRATION OF FOUNDATION WALL -PROVIDE GRAVEL SUPPORT FOR SEWER
Footing Inspection - Residential Passed 11/03/2021
Informational
11/03/2021
FOOTING APPROVED BY ENGINEER
Water Service Inspection - R Passed 11/4/2021 (8:00) 11/4/2021 11/04/2021
Underslab Plumbing Inspection - Residential Failed 11/10/2021 11/10/2021 11/10/2021
Misc
Corrective Action Required
11/10/2021
-Provide erosion control at perimeter, gravel filter and post address before any further inspections
Misc
Corrective Action Required
11/10/2021
-Provide erosion control at perimeter, gravel filter, clean dirt and debris from street and post address before any further inspections
Electrical Service Inspection Passed 3/11/2022 3/10/2022 03/10/2022
Gas Service Inspection - Residential Passed 3/10/2022 3/10/2022 03/10/2022
All Rough Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/10/2022
**RESTORE EROSION CONTROL ALONG THE REAR OF LOT. NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE -Complete framing at front entry -Install hanger above entry door -Fb foyer, stair, and great room fireplace wall from roof; Fb fireplace space from roof -Complete framing at fireplace and secure fireplace to framing; complete electrical -Install roof flashing at rear great room wall -The dryer duct cannot be distorted from its 4” round shape. -Nail corner studs in master closet -Complete electrical at master closet and master bathroom floor heater -Connect ducts to all bathroom fans -Have engineer address hanger nailing for the 14” lvl above foyer -Install ceiling joist hanger at kitchen lvl beam connection -Snow blocking at dining wall roof step flashings -Protect wiring at rear dining bottom wall plate -Provide CSPF walls at rear dining wall per plan -Install joist hangers at connections to the double 2x12 ceiling beam above bathroom &mud; provide full support at exterior wall end -Install hanger above garage -Provide attic access -Anchor garage sill plates within middle 1/3 of plates and within 12” of breaks; provide min 2 anchors for short sill plate; anchor 3rd car garage sill plates -Frame around garage I beam -Install tension straps at portal opening side per code -Fb basement stair and front basement bedroom wall vertically at ten ft or less; fb all wall from horizontal space such as joist and soffit space ; Fb space at basement bathroom tub -Nail hanger above bottom stair landing -Insulation used as fire blocking material must be secured (staple) in place. If I can move it with the measuring tape, then it needs to be stapled in place -Securely fasten all wiring to soffit framing per code, not just lay them onto framing -Toe nail all joists to top plates -Provide triple joist underneath fireplace wall **DO NOT INSULATE
All Rough Inspection - Residential Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
03/10/2022
**REPAIR EROSION CONTROL AT REAR OF LOT. NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE -Fb foyer, stair, and great room fireplace wall from roof; Fb fireplace space from roof **Fb gaps at fire blockings -Provide CSPF walls at rear dining wall per plan **Strap header to studs -Fb basement stair and front basement bedroom wall vertically at ten ft or less; fb all wall from horizontal space such as joist and soffit space **Fb not done per code. Vertical fire blocking in bedroom must be 3/4” sheathing; Fb gaps; Fb ALL wall spaces from soffit; vertical fire blocking at stair not done -Addendum: support patio roof beams at wall corners (Shim excessive gaps) **OK TO INSULATE
All Rough Inspection - Residential Passed 4/25/2022 4/25/2022 04/25/2022
Misc
Resolved
04/25/2022
**REPAIR EROSION CONTROL AT REAR OF LOT. NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE -Addendum: support patio roof beams at wall corners (Shim excessive gaps) **OK TO INSULATE
Driveway Inspection Partial 6/30/2022 6/30/2022 06/30/2022
Misc
Informational
06/30/2022
6-30-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Driveway Inspection Passed 7/5/2022 7/5/2022 07/06/2022
Misc
Informational
06/30/2022
6-30-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Misc
Informational
07/06/2022
7-6-22 AN driveway looks good and has expansion joints at curb and right of way.
Piers/Caissons Inspection - Residential Passed 10/06/2022
Informational
10/06/2022
PIERS APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Failed 10/6/2022 10/6/2022 10/06/2022
Misc
Corrective Action Required
10/06/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city -Underslab plumbing not inspected and approved. -As-graded plot plan is required -Obtain permit for the rear retaining wall over 4 ft tall -Provide min 36” downspouts water discharge -Provide rear floodlight -Lag deck ledger board to rim joists per code; provide engineer address for deck beam support at house end; deck beam not attached to post with 2 through bolts per code -Provide min 6” clearance from siding and window trim to grade -Install light outside rear exterior double door -Reground the service to rod. Drive the grounding rod into ground -Garage door not self-closing -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish -Complete exhaust of kitchen hood; Provide breaker lock for kitchen hood -Provide spark rings at all boxes recessed behind combustible wall finish throughout house -Provide AFCI protection for all outlets required per NEC 210.12. (Breaker 21) -Install backflow preventer at hose bibb -Provide breaker lock for oven and kitchen hood -Complete water exhaust to outside
Underslab Plumbing Inspection - Residential Passed 10/07/2022
Misc
Resolved
10/07/2022
-Provide erosion control at perimeter, gravel filter and post address before any further inspections
Misc
Resolved
10/07/2022
-Provide erosion control at perimeter, gravel filter, clean dirt and debris from street and post address before any further inspections
Plot Plan Inspection Passed 10/13/2022 10/13/2022
Occupancy Inspection - Codes Residential Failed 10/14/2022 10/14/2022 10/14/2022
Misc
Corrective Action Required
10/06/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city **the permit application is not completed -Provide engineer address for deck beam support at house end; deck beam not attached to post with 2 through bolts per code **I talked to the engineer, Mr. David Mezger. He will reevaluate the deficiencies above -Provide min 6” clearance from siding and window trim to grade ** build a rock bed under the window trim to meet the requirement above -Provide spark rings at all boxes recessed behind combustible wall finish throughout house **Receptacle boxes in master bedroom
Occupancy Inspection - Codes Residential Ready for Temp CO 10/14/2022
Misc
Corrective Action Required
10/14/2022
-Provide engineer address for deck beam support at house end; deck beam not attached to post with 2 through bolts per code **I talked to the engineer, Mr. David Mezger. He will reevaluate the deficiencies above
Occupancy Inspection - Codes Residential Temporary C of O 11/10/2022 11/10/2022 11/10/2022
Misc
Corrective Action Required
10/14/2022
-Provide engineer address for deck beam support at house end; deck beam not attached to post with 2 through bolts per code **I talked to the engineer, Mr. David Mezger. He will reevaluate the deficiencies above -Provide drainage from the rock bed outside the basement window. A picture shown with water pooling above the rock bed
Occupancy Inspection - Codes Residential Temporary C of O 11/14/2022 11/28/2022 11/28/2022
Misc
Corrective Action Required
11/10/2022
-Deck beam not attached to post with 2 through bolts or equivalent connection -Provide drainage from the rock bed outside the basement window. A picture shown with water pooling above the rock bed
Occupancy Inspection - Codes Residential Full C of O 12/2/2022 12/02/2022
Misc
Resolved
12/02/2022
-Provide drainage from the rock bed outside the basement window. A picture shown with water pooling above the rock bed
Documents & Images
Date Uploaded File Type Document Name
08/16/2021 Monticello 4th Plat Lot 132 21_0810
08/16/2021 Residental Permit Application_Lees summit
08/16/2021 license tax form
08/17/2021 Permit Codes Residential Plan Review
08/17/2021 Approved Plans APPROVED PLANS
08/17/2021 Plot Plan APPROVED PLOT PLAN
08/18/2021 Permit Codes Residential Plan Review
08/25/2021 Letter Stop Work Order
08/25/2021 Letter Stop Work Order
10/04/2021 Receipt Receipt for transaction:2021-007762
10/05/2021 Garys Fndn 4816 NE Freehold Ct Lee's Summit Mo Footing Forming & Reinforcement Report 9-20-21
10/07/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
02/01/2022 4816 NE Freehold Ct_DECK PIER INSP_2022-01-31
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
04/04/2022 Lot 132 Monticello - Field Issue
04/06/2022 Letter INSPECTION SUMMARY
04/11/2022 4816 NE Freehold Ct_ADDN DECK PIER INSP_2022-04-07
04/25/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/07/2022 BeHome 132 Monticello Ground Rough Letter
10/07/2022 Letter INSPECTION SUMMARY
10/10/2022 Scope_of_Work_Statement irrigation
10/10/2022 Monticello 4th Plat Lot 132 irrigation-wall
10/12/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
10/13/2022 4816 ne
10/13/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/14/2022 IMG_2120
10/14/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/14/2022 Receipt Receipt for transaction:2022-008293
11/07/2022 3575LA
11/07/2022 4816 Freehold Ct (10-18-22)
11/09/2022 Approved Plans APPROVED PLANS
11/10/2022 Certificate/License Codes Temporary Certificate of Occupancy
11/11/2022 Final_2022_11_03_DPier_Pat Cochran_REVISED
11/28/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/02/2022 Letter Codes Final Certificate of Occupancy
12/02/2022 Letter Field Certificate of Occupancy
12/02/2022 Email Freehold
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home