Summary
PRRES20213828
Building Permit - Residential
Certificate of Occupancy
ZB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 08/19/2021 12:00 AM by username 'Nick Lightner'. STOP WORK ORDER removed on 08/25/2021 12:00 AM by username 'Nick Lightner'.
07/23/2021
08/05/2021
01/22/2022
10/18/2022
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
Nick Zvacek, Address:1009 Industrial Drive, Phone:(816) 325-3440  
LEAH@ZVACEKCONSTRUCTION.COM  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ZB CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $480.00 $480.00 Paid 08/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/05/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/05/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/05/2021
9110078-Valuation Fee New Single Family $1,241.92 $1,241.92 Paid 08/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/14/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed - Stop Work 8/19/2021 8/19/2021 08/19/2021
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Silt fence needs to be installed on the property, also in the rear of the lot. Will be shutting down future inspections till fixed.
Erosion Control Inspection Residential Passed 8/25/2021 8/25/2021 08/25/2021
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Silt fence needs to be installed on the property, also in the rear of the lot. Will be shutting down future inspections till fixed.
Misc
Informational
08/25/2021
8/25/21 15:25 - Erosion fence is installed around the property, lifting stop work order.
Sewer Service Inspection - R Partial 8/30/2021 (1:45) 8/30/2021 08/30/2021
Misc
Corrective Action Required
08/30/2021
PARTIAL FROM STUB TO ~ 20 FT FROM HOUSE
Water Service Inspection - R Passed 8/30/2021 08/30/2021
Sewer Service Inspection - R Passed 8/31/2021 08/31/2021
Misc
Resolved
08/31/2021
PARTIAL FROM STUB TO ~ 20 FT FROM HOUSE
Underslab Plumbing Inspection - Residential Partial 9/13/2021 9/13/2021 09/13/2021
Misc
Corrective Action Required
09/13/2021
**POST ADDRESS. NO FURTHER INSPECTION IF ADDRESS IS NOT POSTED Underslab plumbing OK
Underslab Plumbing Inspection - Residential Passed 9/15/2021 9/15/2021 09/15/2021
Misc
Resolved
09/15/2021
**POST ADDRESS. NO FURTHER INSPECTION IF ADDRESS IS NOT POSTED Underslab plumbing OK
Piers/Caissons Inspection - Residential Passed 10/8/2021 (9:00) 10/8/2021 10/08/2021
Gas Service Inspection - Residential Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/26/2022
-Provide min ten psi pressure for testing
All Rough Inspection - Residential Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/26/2022
-Nail siding at edge and to sill plates 6” oc -Install trimmings and flashing&trim above window -Deck beam shall be double 2x12; Deck posts shall be notched for beam bearing; The beam-post connections shall connected with two 1/2” through bolts; support the outer joists with proper hanger; lag ledger board to rim band -Garage PFH walls sheathing shall be nailed to all studs and sill plates 3” oc -Fb foyer wall from roof; Fb all wall plate holes and penetrations -Fb fireplace space from roof with 3/4” sheathing is required. Fb the backside of space -Seal penetrations of return air space -Dryer duct spans 27 ft with 3 90-deg elbows -Install plumbing roof flashings -Land roof load to bearing wall at master bathroom/laundry/closet -Provide wall receptacle at cabinet with countertop -Install transom windows -Deck wall covered prior to inspection. Expose everything -Install collar ties per code above great room, deck, garage -Fb kitchen walls from roof; Fb all wall space from roof throughout -Anchor garage sill plates within 12” of breaks -Anchor garage PFH wall sill plates within middle 1/3 of plates. Anchor with 2”x2”x3/16” washers -Frame around garage I beam -Provide triple 14” lvl beam above stair -Fb basement wall per code with 3/4” sheathing ; Fb wall vertically at max ten ft interval. This space also include space above windows. Fb with 3/4” sheathing and Fb all gaps; Fb wall from fur down ceiling space at gaps. Use 3/4” sheathing as required by code -Anchor basement sill plates within 12” of breaks -At rear bedroom, pan off return air space from the rest of unused joist space and seal all penetrations -The bath fan duct length exceed max allowed per IRC table 1504.2 -At front basement bedroom, unblock the return air space and pan off RA space from fur down ceiling space -Move electrical wirings inside wall space at front basement bedroom closet -Support the 3” horizontal DVW every 4” or less -At basement bathroom, unblock the return air space and pan off RA space from fur down ceiling space and from shower space -Provide security compliance for basement door. Install double jamb studs at both sides of door and install blockings -Support 1/2” gas piping every six ft max -Fb stair stringer space from ceiling space -Complete electrical to rear south closet light -Provide triple lvl beam above bedroom 2 per plan below bearing wall **DO NOT INSULATE
Electrical Service Inspection Passed 1/26/2022 1/26/2022 01/26/2022
All Rough Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Misc
Corrective Action Required
01/26/2022
-Nail siding at edge and to sill plates 6” oc -Install trimmings and flashing&trim above window -Deck beam shall be double 2x12; Deck posts shall be notched for beam bearing; The beam-post connections shall connected with two 1/2” through bolts; support the outer joists with proper hanger; lag ledger board to rim band -Garage PFH walls sheathing shall be nailed to all studs and sill plates 3” oc -Fb foyer and fireplace/bedroom wall from roof; Fb all wall plate holes and penetrations -Fb fireplace space from roof with 3/4” sheathing is required. Fb the backside of space -Seal penetrations of return air space -Dryer duct spans 27 ft with 3 90-deg elbows -Land roof load to bearing wall at master bathroom/laundry/closet -Provide wall receptacle at cabinet with countertop. FYI: cabinet with countertop is considered as a wall space where receptacle spacing requirement is applied. NEC210.52 -Install transom windows -Deck wall covered prior to inspection. Expose everything -Install collar ties per code above great room, deck, garage -Fb kitchen walls from roof; Fb all wall space from roof throughout -Anchor garage sill plates within 12” of breaks -Anchor garage PFH wall sill plates within middle 1/3 of plates. Anchor with 2”x2”x3/16” washers -Frame around garage I beam -Provide triple 14” lvl beam above stair -Fb basement wall per code with 3/4” sheathing ; Fb wall vertically at max ten ft interval. This space also include space above windows. Fb with 3/4” sheathing and Fb all gaps; Fb wall from fur down ceiling space at gaps. Use 3/4” sheathing as required by code -Anchor basement sill plates within 12” of breaks -At rear bedroom, pan off return air space from the rest of unused joist space and seal all penetrations -The bath fan duct length exceed max allowed per IRC table 1504.2 -At front basement bedroom 2, unblock the return air space and pan off RA space from fur down ceiling space -Move electrical wirings into wall space at front basement bedroom 2 closet -Support the 3” horizontal DVW every 4” or less in soffit outside basement bedrooms -At basement bathroom, unblock the return air space and pan off RA space from fur down ceiling space and from shower space -Provide security compliance for basement door. Install double jamb studs at both sides of door and install blockings -Fb stair stringer space from ceiling space -Provide triple lvl beam above bedroom 2 per plan below bearing wall **DO NOT INSULATE **1/31/22-THIS IS A 2ND ALL-ROUGH INSPECTION. NOT READY FEE WILL BE ASSESSED FOR EACH SUBSEQUENT FAILED INSPECTION
Gas Service Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Misc
Corrective Action Required
01/26/2022
-Provide min ten psi pressure for testing
Footing Inspection - Residential Passed 02/10/2022
Informational
02/10/2022
FOOTING INSPECTED AND APPROVED BY ENGINEER
Gas Service Inspection - Residential Failed 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
01/31/2022
-Provide min ten psi pressure for testing **pressure currently at 9 psi
All Rough Inspection - Residential Not Ready 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
01/31/2022
-Nail siding at edge and to sill plates 6” oc -Install trimmings and flashing&trim above window -Deck beam shall be double 2x12; Deck posts shall be notched for beam bearing; The beam-post connections shall connected with two 1/2” through bolts; support the outer joists with proper hanger; lag ledger board to rim band -Garage PFH walls sheathing shall be nailed to all studs and sill plates 3” oc -Fb foyer and fireplace/bedroom wall from roof; Fb all wall plate holes and penetrations -Fb fireplace space from roof with 3/4” sheathing is required. Fb the backside of space -Seal penetrations of return air space -Dryer duct spans 27 ft with 3 90-deg elbows -Land roof load to bearing wall at master bathroom/laundry/closet -Provide wall receptacle at cabinet with countertop. FYI: cabinet with countertop is considered as a wall space where receptacle spacing requirement is applied. NEC210.52 -Install transom windows -Deck wall covered prior to inspection. Expose everything -Install collar ties per code above great room, deck, garage -Fb kitchen walls from roof; Fb all wall space from roof throughout -Anchor garage sill plates within 12” of breaks -Anchor garage PFH wall sill plates within middle 1/3 of plates. Anchor with 2”x2”x3/16” washers -Frame around garage I beam -Provide triple 14” lvl beam above stair -Fb basement wall per code with 3/4” sheathing ; Fb wall vertically at max ten ft interval. This space also include space above windows. Fb with 3/4” sheathing and Fb all gaps; Fb wall from fur down ceiling space at gaps. Use 3/4” sheathing as required by code -Anchor basement sill plates within 12” of breaks -At rear bedroom, pan off return air space from the rest of unused joist space and seal all penetrations -The bath fan duct length exceed max allowed per IRC table 1504.2 -At front basement bedroom 2, unblock the return air space and pan off RA space from fur down ceiling space -Move electrical wirings into wall space at front basement bedroom 2 closet -Support the 3” horizontal DVW every 4” or less in soffit outside basement bedrooms -At basement bathroom, unblock the return air space and pan off RA space from fur down ceiling space and from shower space -Provide security compliance for basement door. Install double jamb studs at both sides of door and install blockings -Fb stair stringer space from ceiling space -Provide triple lvl beam above bedroom 2 per plan below bearing wall **DO NOT INSULATE **1/31/22-THIS IS A 2ND ALL-ROUGH INSPECTION. NOT READY FEE WILL BE ASSESSED FOR EACH SUBSEQUENT FAILED INSPECTION **2/10/22-NOT READY FEE ASSESSED
All Rough Inspection - Residential Failed 3/14/2022 3/14/2022 03/14/2022
Misc
Corrective Action Required
02/10/2022
-Install trimmings and flashing&trim above window -Support the outer deck joists with proper hanger; lag ledger board to rim band -Provide wall receptacle at cabinet with countertop. FYI: cabinet with countertop is considered as a wall space where receptacle spacing requirement is applied. NEC210.52 **if you have cabinets with countertop, the receptacles within the cabinets do not count as the required wall receptacle -Deck wall covered prior to inspection. Expose everything -Install collar ties per code above great room -Anchor garage sill plates within 12” of breaks -Fb basement wall per code with 3/4” sheathing **fb gap at top of vertical fire blocking. Use fire blocking foam **look up inside bedroom 2 exterior wall space, Fb gaps at top -Anchor basement sill plates within 12” of breaks **anchor rear basement rec room wall no more than 6 ft apart ; anchor bedroom 3 sill plate within 12” of break -Move electrical wirings into wall space at front basement bedroom 2 closet **or complete soffit and fire block as required -Provide security compliance for basement door. Install double jamb studs at both sides of door and install blockings -Fb stair stringer space from ceiling space **OK TO INSULATE **1/31/22-THIS IS A 2ND ALL-ROUGH INSPECTION. NOT READY FEE WILL BE ASSESSED FOR EACH SUBSEQUENT FAILED INSPECTION **2/10/22-NOT READY FEE ASSESSED
Gas Service Inspection - Residential Failed 3/14/2022 03/14/2022
Misc
Corrective Action Required
02/10/2022
-Provide min ten psi pressure for testing **pressure currently at 5 psi
All Rough Inspection - Residential Partial 3/18/2022 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/14/2022
-Support the outer deck joists with proper hanger; lag ledger board to rim band -Deck wall covered prior to inspection. Expose everything **secure wiring per code. Secure away from fireplace box **OK TO ROCK **1/31/22-THIS IS A 2ND ALL-ROUGH INSPECTION. NOT READY FEE WILL BE ASSESSED FOR EACH SUBSEQUENT FAILED INSPECTION **2/10/22-NOT READY FEE ASSESSED
Gas Service Inspection - Residential Passed 3/18/2022 3/18/2022 03/18/2022
Misc
Resolved
03/18/2022
-Provide min ten psi pressure for testing **pressure currently at 5 psi
Driveway Inspection Partial 4/22/2022 04/22/2022
Misc
Informational
04/22/2022
4-22-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 4/25/2022 4/25/2022 04/25/2022
Misc
Informational
04/22/2022
4-22-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
04/25/2022
4-25-22 AN driveway looks good and has expansion joints at curb and right of way
Plot Plan Inspection Passed 9/29/2022 09/29/2022
Occupancy Inspection - Codes Residential Failed 10/7/2022 10/7/2022 10/07/2022
Miscellaneous Correction
Corrective Action Required
10/07/2022
- all rough inspection pending - Obtain an irrigation permit and submit a back flow certification - Pay all fees - Address to be contrasting in color - No water regulator - Water supply incomplete - Missing outlet cover basement bedroom near bar - Missing handrail to basement - Hood wiring exposed - Kitchen counter outlets incomplete - Steps at garage entry over 3/8” variance - No cover for attic access - Missing outlet covers in laundry - Smoke detector covered in master bedroom - Provide gutters and down spouts - Provide splash blocks - Land sewer trace wire at grade
All Rough Inspection - Residential Passed 10/13/2022 10/13/2022 10/13/2022
Misc
Resolved
10/13/2022
-Support the outer deck joists with proper hanger; lag ledger board to rim band -Deck wall covered prior to inspection. Expose everything **secure wiring per code. Secure away from fireplace box **OK TO ROCK **1/31/22-THIS IS A 2ND ALL-ROUGH INSPECTION. NOT READY FEE WILL BE ASSESSED FOR EACH SUBSEQUENT FAILED INSPECTION **2/10/22-NOT READY FEE ASSESSED
Occupancy Inspection - Codes Residential Ready for Temp CO 10/14/2022 10/14/2022 10/14/2022
Miscellaneous Correction
Corrective Action Required
10/07/2022
- Obtain an irrigation permit and submit a back flow certification **permit application still in applied status -Land sewer trace wire at grade
Occupancy Inspection - Codes Residential Full C of O 10/18/2022 10/18/2022
Miscellaneous Correction
Resolved
10/18/2022
-Land sewer trace wire at grade
Documents & Images
Date Uploaded File Type Document Name
07/23/2021 Lot 131 License_Tax_Application
07/23/2021 Lot 131 Residental Permit Application_1
07/26/2021 Permit Codes Residential Plan Review
07/26/2021 Approved Plans APPROVED PLANS
08/03/2021 Plot Plan APPROVED PLOT PLAN
08/03/2021 Permit Codes Residential Plan Review
08/05/2021 Permit DS Building Permit
08/05/2021 Receipt Receipt for transaction: 2021-006267
08/18/2021 4821 NE Freehold Ct LSMO Monticello Lot 131 NZC Permit 2021-3828 3rd Party Footing Inspection Report 8-16-21
08/19/2021 Letter Stop Work Order
08/25/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
09/28/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
09/29/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/14/2022 Receipt Receipt for transaction:2022-008274
10/17/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/17/2022 Receipt Receipt for transaction:2022-008300
10/18/2022 Letter Codes Final Certificate of Occupancy
10/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home