Permit Application Status

PRRES20213816


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213816
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW FOUR PLEX - ROOF TRUSSES - UNFINISHED BASEMENT STOP WORK ORDER generated on 02/01/2022 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 02/07/2022 12:00 AM by username 'Patrick Schonfeldt'.
07/23/2021
07/30/2021
01/22/2022
11/21/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
  
  
  
  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,347.27 $3,347.27 Paid 07/30/2021
8331507-Sewer Connection Fee $1,500.00 $1,500.00 Paid 07/30/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/30/2021
7232302-Residential Excise Tax Fee $4,308.48 $4,308.48 Paid 07/30/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 07/30/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 07/30/2021
8331504-EFHB Middle Big Creek, Full $1,674.00 $1,674.00 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/23/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 9/15/2021 09/15/2021
Miscellaneous Correction
Corrective Action Required
09/15/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OR POUR
Sewer Service Inspection - R Partial 2/1/2022 02/01/2022
Misc
Informational
09/15/2021
CALLED IN WRONG PERMIT # Michael Harkins 09/16/2021 9:36 AM
Misc
Informational
02/01/2022
3714 UNIT C OK TO COVER
Footing Inspection - Residential Failed - Stop Work 2/1/2022 02/01/2022
Miscellaneous Correction
Corrective Action Required
09/15/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OR POUR
Miscellaneous Correction
Corrective Action Required
02/01/2022
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR PROVIDE ADDRESS
Sewer Service Inspection - R Partial 2/7/2022 (11:00) 2/7/2022 02/07/2022
Misc
Resolved
02/07/2022
Misc
Informational
02/01/2022
3714, 3716 OK TO COVER
Footing Inspection - Residential Failed 2/7/2022 2/7/2022 02/07/2022
Miscellaneous Correction
Resolved
02/07/2022
Miscellaneous Correction
Corrective Action Required
02/01/2022
THIRD PARTY INSPECTION REPORT MISSING REQUIRED INFORMATION, UFER LOCATION(S), COMPLETE MISSING INFORMATION AND UPLOAD TO PERMIT
Sewer Service Inspection - R Partial 2/8/2022 02/08/2022
Misc
Informational
02/07/2022
3714, 3716, 3712 OK TO COVER
Sewer Service Inspection - R Passed 2/8/2022 2/8/2022 02/08/2022
Misc
Informational
02/08/2022
3714, 3716, 3712,3710 OK TO COVER
Footing Inspection - Residential Passed 02/08/2022
Miscellaneous Correction
Informational
02/08/2022
APPROVED PER ALBERT HERMANS 12/23/21
Underslab Plumbing Inspection - Residential Not Ready 2/11/2022 2/11/2022 02/11/2022
Misc
Corrective Action Required
02/11/2022
INSPECTION DENIED -POST ADDRESSES -EROSION CONTROL REQUIRED ON LOT
Erosion Control Inspection Residential Failed 2/11/2022 2/11/2022 02/11/2022
DCM5 ESC INSP DENIED
Corrective Action Required
02/11/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Water Service Inspection - R Passed 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
3710, 3712, 3714, 3716 OK
Erosion Control Inspection Residential Failed 2/15/2022 2/15/2022 02/15/2022
DCM5 ESC INSP DENIED
Resolved
02/15/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 2/24/2022 2/24/2022 02/24/2022
Misc
Informational
02/24/2022
3710, 3712, 3714, 3716 OK
Erosion Control Inspection Residential Partial 2/24/2022 2/24/2022 02/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
02/24/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 8/18/2023 8/18/2023 08/18/2023
Miscellaneous Correction
Corrective Action Required
08/18/2023
3710 - Garage anchor bolts must be in the middle 1/3 of the bottom plate and tighten all nuts - Steel support posts in living room needs to be secured at the bottom - Address window in the kitchen that does not have a header - LIB in closet up stairs that backs up against the stairwell is cut off and not completed - Ceiling fire blocking is needed in chase upstairs against stairwell wall - All attic wood up against the rated wall needs to have a 1 inch gap between the two - No attic access? - Joist hangers are needed in the cut 2x12’s above the front porch where the bathroom is 3712 - Tighten all anchor bot nuts in the garage - Steel support posts in living room need to be secured down at the bottom - Address missing header above kitchen window - Attic access does not have the required 30 inches of head room height - Address wood up against rated assembly north wall - Address cut LIB in the closet up against the stairwell 3714 - Anchor bolts in garage bottom plate must be located in the middle 1/3 of the board and all nuts must be tightened down - LIB in garage entry is not fully secured - Steel support post in living room need to be secured at the bottom - Nails missing in ceiling joist hanger LVL by kitchen/living room - Fire blocking in top plate is missing by the steel post in the living room - Nails are missing in the ceiling joist hanger in the entry - Address kitchen window without a header - Address cut LIB in the upstairs closet that back up against the stairwell 3716 - bolts on bottom plate anchors need to be properly tightened down in the garage - Fire blocking in top plate penetrations in garage up stairs shared bathroom and kitchen is missing - Steel support post in living room needs to be secured at the bottom - Ceiling joist hangers need to be installed where the 2x12 was cut above the front porch for the bathroom - Address missing header above the kitchen window - Electrical nail plate is needed in the master bedroom S/E corner - A wall stud is missing in the S/W bedroom - Stair stringer to the basement is missing a hanger
Electrical Service Inspection Passed 8/18/2023 8/18/2023 08/18/2023
Gas Service Inspection - Residential Passed 8/18/2023 8/18/2023 08/18/2023
Rated Assembly Inspection Passed 8/18/2023 8/18/2023 08/18/2023
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
Misc
Corrective Action Required
02/24/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Miscellaneous Correction
Corrective Action Required
08/18/2023
Full property erosion control is not in place at the time of all rough inspection. Erosion control must be in place until occupancy
All Rough Inspection - Residential Passed 8/23/2023 8/23/2023 08/23/2023
Miscellaneous Correction
Resolved
08/23/2023
3710 - Garage anchor bolts must be in the middle 1/3 of the bottom plate and tighten all nuts - Steel support posts in living room needs to be secured at the bottom - Address window in the kitchen that does not have a header - LIB in closet up stairs that backs up against the stairwell is cut off and not completed - Ceiling fire blocking is needed in chase upstairs against stairwell wall - All attic wood up against the rated wall needs to have a 1 inch gap between the two - Attic access has a/c 3712 - - Address wood up against rated assembly north wall - 3714 - Anchor bolts in garage bottom plate must be located in the middle 1/3 of the board and all nuts must be tightened down - LIB in garage entry is not fully secured - Steel support post in living room need to be secured at the bottom - Nails missing in ceiling joist hanger LVL by kitchen/living room - Fire blocking in top plate is missing by the steel post in the living room - Nails are missing in the ceiling joist hanger in the entry - Address kitchen window without a header - Address cut LIB in the upstairs closet that back up against the stairwell 3716 - bolts on bottom plate anchors need to be properly tightened down in the garage - Fire blocking in top plate penetrations in garage up stairs shared bathroom and kitchen is missing - Steel support post in living room needs to be secured at the bottom - Ceiling joist hangers need to be installed where the 2x12 was cut above the front porch for the bathroom - Address missing header above the kitchen window - Electrical nail plate is needed in the master bedroom S/E corner - A wall stud is missing in the S/W bedroom - Stair stringer to the basement is missing a hanger
Erosion Control Inspection Residential Failed 8/25/2023 08/25/2023
Misc
Corrective Action Required
08/18/2023
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Miscellaneous Correction
Corrective Action Required
08/18/2023
Full property erosion control is not in place at the time of all rough inspection. Erosion control must be in place until occupancy
Miscellaneous Correction
Corrective Action Required
08/25/2023
Full erosion control is missing, never installed or damaged and needs to be installed. Full erosion control must be protected until occupancy
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Misc
Corrective Action Required
08/25/2023
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Miscellaneous Correction
Corrective Action Required
08/25/2023
Full property erosion control is not in place at the time of all rough inspection. Erosion control must be in place until occupancy
Miscellaneous Correction
Corrective Action Required
08/25/2023
Full erosion control is missing, never installed or damaged and needs to be installed. Full erosion control must be protected until occupancy
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is missing torn down or never installed. Full property erosion control must be in place and maintained until full CO. Streets must be cleared of dirt and gravel along with proper erosion control. No inspections shall be completed until erosion control is in place and maintained. 08/29/2023 KBEARD
Driveway Inspection Partial 9/11/2023 9/11/2023 09/11/2023
Misc
Informational
09/11/2023
9-11-23 A.A DW is formed, aggregate is compacted. Will need to maintain 2% slope through driveway but conditions can change, approved to pour
Sidewalk Inspection Partial 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
09/11/2023
9-11-23 A.A SW is formed , aggregate is compacted and slopes are in compliance. Conditions can change, approved to pour.
Driveway Inspection Partial 9/18/2023 9/18/2023 09/18/2023
Misc
Informational
09/11/2023
9-11-23 A.A DW is formed, aggregate is compacted. Will need to maintain 2% slope through driveway but conditions can change, approved to pour 9-18-23 A.A DW is poured. Slopes are in compliance. Cannot pass until forms are pulled
Sidewalk Inspection Partial 9/18/2023 9/18/2023 09/18/2023
Misc
Informational
09/18/2023
9-18-23 A.A SW is poured on east side of house ( front) . Slopes are in compliance . Forms are still on. Sidewalk will need to be poured still on north side of house to connect sidewalk to existing
Sidewalk Inspection Partial 9/20/2023 9/20/2023 09/20/2023
Misc
Informational
09/18/2023
9-18-23 A.A SW is poured on east side of house ( front) . Slopes are in compliance . Forms are still on. Sidewalk will need to be poured still on north side of house to connect sidewalk to existing 9-20-23 A.A, SW is framed from drive to the north to existing sidewalk. Slopes are in compliance . Conditions can change. Approved to pour.
Driveway Inspection Passed 9/25/2023 9/25/2023 09/25/2023
Misc
Informational
09/18/2023
9-11-23 A.A DW is formed, aggregate is compacted. Will need to maintain 2% slope through driveway but conditions can change, approved to pour 9-18-23 A.A DW is poured. Slopes are in compliance. Cannot pass until forms are pulled 9-25-23 A.A forms pulled . Passed
Sidewalk Inspection Partial 9/27/2023 9/27/2023 09/27/2023
Misc
Informational
09/20/2023
9-18-23 A.A SW is poured on east side of house ( front) . Slopes are in compliance . Forms are still on. Sidewalk will need to be poured still on north side of house to connect sidewalk to existing 9-20-23 A.A, SW is framed from drive to the north to existing sidewalk. Slopes are in compliance . Conditions can change. Approved to pour. 9-27-23 A.A SW is poured, Some of the frames are pulled. Slopes are in compliance. Cannot pass until all forms are pulled.
Sidewalk Inspection Passed 10/4/2023 10/4/2023 10/04/2023
Misc
Informational
09/27/2023
9-18-23 A.A SW is poured on east side of house ( front) . Slopes are in compliance . Forms are still on. Sidewalk will need to be poured still on north side of house to connect sidewalk to existing 9-20-23 A.A, SW is framed from drive to the north to existing sidewalk. Slopes are in compliance . Conditions can change. Approved to pour. 9-27-23 A.A SW is poured, Some of the frames are pulled. Slopes are in compliance. Cannot pass until all forms are pulled. 10-4-23 Dustin A, forms are pulled passed
Erosion Control Inspection Residential Passed 10/25/2023 10/25/2023
Misc
Resolved
10/25/2023
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Miscellaneous Correction
Resolved
10/25/2023
Full property erosion control is not in place at the time of all rough inspection. Erosion control must be in place until occupancy
Miscellaneous Correction
Resolved
10/25/2023
Full erosion control is missing, never installed or damaged and needs to be installed. Full erosion control must be protected until occupancy
Miscellaneous Correction
Resolved
10/25/2023
Erosion control is missing torn down or never installed. Full property erosion control must be in place and maintained until full CO. Streets must be cleared of dirt and gravel along with proper erosion control. No inspections shall be completed until erosion control is in place and maintained. 08/29/2023 KBEARD
Plot Plan Inspection Passed 10/27/2023 10/27/2023
Occupancy Inspection - Codes Residential Failed 10/27/2023 10/27/2023 10/27/2023
Misc
Corrective Action Required
10/27/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Handrail in garage falling off, also missing spindles at garage stairs -Seal all exterior wall penetrations -Remove all battery tabs on smokes -Address extension cord powering irrigation
Occupancy Inspection - Codes Residential Failed 10/31/2023 10/31/2023 10/31/2023
Misc
Partial Correction
10/31/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Corrective Action Required
10/31/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail at garage will not support 200lb lateral load -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel -Anti tip device at stove not functioning
Occupancy Inspection - Codes Residential Failed 11/3/2023 11/3/2023 11/03/2023
Misc
Partial Correction
10/31/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Corrective Action Required
10/31/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel 3710 - Electrical receptacles are hanging from the kitchen backsplash’s and are not secured to the wall - None of the three bathrooms has a working sink. THIS IS NOT A COMPLETE LIST
Occupancy Inspection - Codes Residential Failed 11/7/2023 11/7/2023 11/07/2023
Misc
Partial Correction
11/03/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Corrective Action Required
11/03/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel 3710 - Electrical receptacles are hanging from the kitchen backsplash’s and are not secured to the wall - None of the three bathrooms has a working sink. THIS IS NOT A COMPLETE LIST
Miscellaneous Correction
Corrective Action Required
11/07/2023
3710 SW Walsh Kitchen backsplash receptacles are not secured to the wall Oven anti tip bracket is not installed or does not work Basement lower hand rail does not meet or exceed the last step nosing Electrical panel does not have a GFCI receptacle attached to it Water heater electrical whip needs to be better secured at the ceiling joist The south wall in the basement needs to have two holes fire blocked in the floor above Water line in basement by the main water inlet needs to be secured to the ceiling joist at the 90 degree angle Hand rail in the upper stair well at the turn around area does not meet or exceed the lower stair nosing at the platform The ground level behind the exterior a/c condenser is lower than the surrounding elevation and will retain water - 3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel
Occupancy Inspection - Codes Residential Failed 11/8/2023 11/8/2023 11/08/2023
Misc
Partial Correction
11/07/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Corrective Action Required
11/07/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel
Miscellaneous Correction
Corrective Action Required
11/07/2023
3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel
Miscellaneous Correction
Informational
11/08/2023
3710 3710 SW Walsh Dr passed for certificate of occupancy. 3712, 3714 and 3716 will be called in for re inspection at a later date. This is a partial CofO for 3710 only 11/08/23 KBEARD
Occupancy Inspection - Codes Residential Failed 11/16/2023 11/16/2023 11/16/2023
Misc
Partial Correction
11/08/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Corrective Action Required
11/08/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel
Miscellaneous Correction
Corrective Action Required
11/08/2023
3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper stair well 3716 SW Walsh Dr -Missing guard rail at front porch -Lower handrail length at basement does not meet riser nosing at middle landing 3714 SW Walsh Full CofO is passed. 3710 and 3714 SW Walsh are the only two that now have full CofO. 11/16/2023 KBEARD
Miscellaneous Correction
Resolved
11/16/2023
3710 3710 SW Walsh Dr passed for certificate of occupancy. 3712, 3714 and 3716 will be called in for re inspection at a later date. This is a partial CofO for 3710 only 11/08/23 KBEARD
Occupancy Inspection - Codes Residential Full C of O 11/21/2023 11/21/2023 11/21/2023
Misc
Resolved
11/21/2023
3712 SW Walsh Dr -Clean out concrete debris in egress well to ensure proper drainage -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove plastic dust covers on smokes -Address extension cord powering irrigation 3714 SW Walsh Dr -Seal all exterior wall penetrations -Adjust self closing hinges at garage door -Missing spindles at garage stairs -Remove all battery tabs on smokes -Address extension cord powering irrigation 3716 SW Walsh Dr -Missing spark ring at receptacle to the right of kitchen sink -Missing spindles at garage stairs
Misc
Resolved
11/21/2023
-3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper platform -Miss GFCI receptacle at panel -3714 SW Walsh Dr -Missing guardrail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing GFCI receptacle at panel 3716 SW Walsh Dr -Missing guard rail at front porch -Handrail length does not meet or exceed nosing at upper platform -Lower handrail length at basement does not meet upper riser -Missing fire blocking to left of stairs in garage -Missing GFCI receptacle at panel
Miscellaneous Correction
Resolved
11/21/2023
3712 SW Walsh Dr -Seal attic access gaps -Handrail length does meet or exceed nosing at upper stair well 3716 SW Walsh Dr -Missing guard rail at front porch -Lower handrail length at basement does not meet riser nosing at middle landing 3714 SW Walsh Full CofO is passed. 3710 and 3714 SW Walsh are the only two that now have full CofO. 11/16/2023 KBEARD
Documents & Images
Date Uploaded File Type Document Name
07/23/2021 OS #10 - PERMIT APP
07/26/2021 OS #10 - Juneau - Farmhouse - Sheets- signed
07/26/2021 Approved Plans APPROVED PLOT PLAN
07/26/2021 Approved Plans APPROVED TRUSS DRAWINGS
07/26/2021 Permit Codes Residential Plan Review
07/30/2021 Permit Codes Residential Plan Review
07/30/2021 Permit DS Building Permit
07/30/2021 Receipt Receipt for transaction:2021-006077
08/23/2021 Approved Plans APPROVED TRUSS LAYOUT
09/15/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
01/27/2022 Approved Plans APPROVED PLANS
02/01/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter Stop Work Order
02/07/2022 3710 SW WALSH DR FTG INSP
02/07/2022 Letter INSPECTION SUMMARY
02/07/2022 Letter INSPECTION SUMMARY
02/08/2022 3710 SW WALSH DR FTG INSP REV
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
06/29/2022 Approved Plans APPROVED PLANS
06/29/2022 Approved Plans APPROVED PLOT PLAN
04/04/2023 OS #10 - Juneau - Farmhouse - Sheets 3_8_23
04/04/2023 10 OSAGE ROOF LAYOUT REV 3-23-23
04/04/2023 2820534 RF SEAL 03222023
04/04/2023 LOT 10 FINAL 3-16-23
04/04/2023 Approved Plans APPROVED PLANS
04/04/2023 Approved Plans approved plot plan
04/04/2023 Approved Plans APPROVED TRUSS LAYOUT
06/19/2023 OS #10 - Juneau - Farmhouse - Sheets A1,A2,A4,A5 REV - SIGNED
06/20/2023 Approved Plans APPROVED PLANS
08/03/2023 10 OSAGE - 230801
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/25/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/23/2023 Receipt Receipt for transaction:2023-007944
10/25/2023 Letter INSPECTION SUMMARY
10/27/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
11/03/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter Codes Final Certificate of Occupancy
11/21/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home