Permit Application Status

PRRES20213593


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213593
Building Permit - Residential
Certificate of Occupancy
SOUTHMARKET DEVELOPERS L L C
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK RETAINING WALL IS OVER 4' TALL AND WILL NEED ENGINEERED DRAWINGS BUILDING ON FILL SO WILL NEED SOILS REPORT BEFORE FOOTING INSPECTION IS DONE REFERENCE FOUNDATION ONLY PERMIT NUMBER 20212727 STOP WORK ORDER generated on 09/03/2021 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 09/08/2021 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER generated on 12/09/2021 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 12/10/2021 12:00 AM by username 'Michael Harkins'.
07/12/2021
07/29/2021
01/09/2022
01/31/2023
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
SOUTHMARKET DEVELOPERS L L C, Address:1550 SW MARKET ST STE 210  
Rick holbrook , Address:528 NW. AA Highway  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/29/2021
8331507-Sewer Connection Fee $690.00 $690.00 Paid 07/29/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/29/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/29/2021
9110078-Valuation Fee New Single Family $2,170.15 $2,170.15 Paid 07/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/29/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/29/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 09/29/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/29/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/30/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/30/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/30/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 8/11/2021 08/11/2021
Water Service Inspection - R Passed 8/11/2021 08/11/2021
Footing Inspection - Residential Failed 8/24/2021 08/24/2021
Miscellaneous Correction
Corrective Action Required
08/24/2021
- NO FOOTING INSPECTION ON RECORD PROVIDE 3RD PARTY FOOTINGS WITHIN 48 HOURS OF POUR - - PROVIDE ADDRESS -
Underslab Plumbing Inspection - Residential Failed 8/24/2021 8/24/2021 08/24/2021
Miscellaneous Correction
Corrective Action Required
08/24/2021
- PROVIDE ADDRESS - - COMPLETE INTERIOR DRAIN TILE - - NO FOOTING INSPECTION ON RECORD -
Underslab Plumbing Inspection - Residential Failed - Stop Work 9/3/2021 9/3/2021 09/03/2021
Miscellaneous Correction
Corrective Action Required
08/24/2021
- PROVIDE ADDRESS - - COMPLETE INTERIOR DRAIN TILE - - NO FOOTING INSPECTION ON RECORD - - PROVIDE 3RD PARTY FOOTING INSPECTION WITHIN 48 HOURS OF POUR -
Underslab Plumbing Inspection - Residential Passed 9/8/2021 09/08/2021
Miscellaneous Correction
Resolved
09/08/2021
Suspended Slab Inspection Failed 12/9/2021 (3:00) 12/9/2021 12/09/2021
Miscellaneous Correction
Corrective Action Required
12/09/2021
NO CITY APPROVED PLANS ON SITE FOOTING INSPECTION ON FOUNDATION ONLY PERMIT # 20212727
Footing Inspection - Residential Failed - Stop Work 12/9/2021 12/09/2021
Miscellaneous Correction
Corrective Action Required
08/24/2021
- NO FOOTING INSPECTION ON RECORD PROVIDE 3RD PARTY FOOTINGS WITHIN 48 HOURS OF POUR - - PROVIDE ADDRESS -
Miscellaneous Correction
Corrective Action Required
12/09/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY FOOTINGS WITHIN 48 HOURS OF POUR ( APEX REPORT ON DRILLED PIERS UPLOADED BUT NO FOOTING )
Footing Inspection - Residential Passed 12/10/2021 12/10/2021
Miscellaneous Correction
Informational
03/16/2022
FOOTING PASSED ON PERMIT # 20212727 FOUNDATION ONLY PERMIT
Miscellaneous Correction
Resolved
12/10/2021
Gas Service Inspection - Residential Passed 3/16/2022 3/16/2022 03/16/2022
Electrical Service Inspection Passed 3/16/2022 3/16/2022 03/16/2022
All Rough Inspection - Residential Failed 3/16/2022 3/16/2022 03/16/2022
Miscellaneous Correction
Corrective Action Required
03/16/2022
NO INSPECTION INCOMPLETE SET OF PLANS ( NO DETAILS S 3.0 THRU ? - SUBMIT CHANGES TO BAY WINDOW ( ENGINEERS LETTER ON SITE ) SUSPENDED SLAB INSPECTION FAILED 12/9/21
All Rough Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Miscellaneous Correction
Corrective Action Required
03/17/2022
Suspended slab inspection failed 12/9/21 Nail hold down at single car garage Nail exterior wall sheathing per code Submit engineers letter for bay window change Provide midpoint support vertical dwv 2" & smaller Support lvls at ridge above master bedroom Tie walls at top plate above bay window master bed Address ceiling joist cut in office closet Provide chase for vent to roof office closet Provide anchor bolt within 12" of plate break south wall garage Engineer to address rafter bearing bed 4 above bay window Engineer to address rafters landing on multiple blocks Provide support ridge master bed Provide support ridge master closet Provide lateral support load bearing beams Seal gas line deck fireplace Fire block west garage wall holes in sheathing Nail intersecting wall corners per code Mud room Laundry seal dwv at top plate Bed 2 fire block hole exterior sheathing Strap top plate in pantry Fire block ceiling line above front door Provide fire blocking dead space at basement fireplace Provide 1" clearance basement fireplace vent Seal fire blocking at dead space behind service panel Repair floor joist pan off in soffit near dbl door basement Provide anchor bolts within 12" of plate breaks exercise room Provide anchor bolts within 12" of plate break south basement wall Provide anchor bolts in 1st step down south foundation wall Tighten anchor bolts basement Complete plumbing above security panel Complete plumbing SW unfinished portion of basement Provide boca plates extending 2" above or below top & bottom plate Support soffits in basement Anchor bolt SCH 40 column at basement shower Fire block chase in Basement bedroom closet Provide anchor bolt within 12" of plate break Basement bedroom rear wall Provide anchor bolt within 12" of plate break SGD basement Seal upward penetration right of basement fire place Seal upward penetration exercise room hose bib Fire block soffit exercise room bath Provide anchor bolt end of plate near service panel Provide flashing above horizontal trim bay window master
Suspended Slab Inspection Passed 3/18/2022 03/18/2022
Miscellaneous Correction
Resolved
03/18/2022
NO CITY APPROVED PLANS ON SITE NO FOOTING INSPECTION ON RECORD PROVIDE 3RD PARTY FOOTING INSPECTION WITHIN 48 HOURS OF POUR ( APEX REPORT ON DRILLED PIERS ONLY NO FOOTING )
Misc
Informational
03/18/2022
3RD PARTY STRUCTURAL SLAB SIGNED & SEALED BY MICHAEL SKEENS
Piers/Caissons Inspection - Residential Passed 3/18/2022 03/18/2022
Misc
Informational
03/18/2022
FOUNDATION & DECK PIERS PASSED ON FOUNDATION ONLY PERMIT # 20212727 3RD PARTY BY APEX
All Rough Inspection - Residential Not Ready 3/22/2022 3/22/2022 03/22/2022
Miscellaneous Correction
Corrective Action Required
03/17/2022
Nail exterior wall sheathing per code Nail intersecting wall corners per code Fire block ceiling line above front door ( not done 3/22/22) Provide fire blocking dead space at basement fireplace ( seal gaps 3/22/22) Seal fire blocking at dead space behind service panel ( seal gaps 3/22/22) Provide anchor bolts within 12" of plate breaks exercise room ( anchor bolts shall be in middle 1/3 of the width of plate ) Complete plumbing above security panel ( not done) Complete plumbing SW unfinished portion of basement ( not done) Fire block chase in Basement bedroom closet ( seal gaps ) Fire block soffit exercise room bath ( seal gaps at pex & dwv ) Provide flashing above horizontal trim bay window master ( not done ) Added 3/22/22 Seal upward penetrations bottom plate master shower Provide 2x6 purlin at master hex bay window per partial roof plan from Vista Structural Engineering letter dated 11/1/21
Erosion Control Inspection Residential Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
remove debris and gravel from street
All Rough Inspection - Residential Not Ready 3/25/2022 3/25/2022 03/25/2022
Miscellaneous Correction
Corrective Action Required
03/22/2022
3/25/22 inspection denied, no plans found on sight house has been insulated, remove insulation from all extierier corners and any other locations needed for re-inspection of items listed. Nail exterior wall sheathing per code Nail intersecting wall corners per code Fire block ceiling line above front door ( not done 3/22/22) Provide fire blocking dead space at basement fireplace ( seal gaps 3/22/22) Seal fire blocking at dead space behind service panel ( seal gaps 3/22/22) Provide anchor bolts within 12" of plate breaks exercise room ( anchor bolts shall be in middle 1/3 of the width of plate ) Complete plumbing above security panel ( not done) Complete plumbing SW unfinished portion of basement ( not done) Fire block chase in Basement bedroom closet ( seal gaps ) Fire block soffit exercise room bath ( seal gaps at pex & dwv ) Provide flashing above horizontal trim bay window master ( not done ) Added 3/22/22 Seal upward penetrations bottom plate master shower Provide 2x6 purlin at master hex bay window per partial roof plan from Vista Structural Engineering letter dated 11/1/21
All Rough Inspection - Residential Failed 3/29/2022 03/29/2022
Miscellaneous Correction
Corrective Action Required
03/25/2022
Nail exterior wall sheathing per code ( NOT DONE TOO MUDDY ) Complete plumbing above security panel unfinished basement ( not done 3/28/22) Complete plumbing SW unfinished portion of basement Radon ? ( not done 3/28/22) Provide flashing above horizontal trim bay window master ( not done 3/28/22 ) CHECK ON FINAL OK TO INSULATE & ROCK
Driveway Inspection Partial 7/19/2022 7/19/2022 07/19/2022
Misc
Informational
07/19/2022
Driveway was framed up with aggregate in and compacted. 7/19/22 ES
Sidewalk Inspection Partial 7/19/2022 07/19/2022
Misc
Informational
07/19/2022
Sidewalk was framed up with aggregate in and compacted. 7/19/22 ES
Sidewalk Inspection Passed 7/25/2022 7/25/2022 08/02/2022
Misc
Informational
07/19/2022
Sidewalk was framed up with aggregate in and compacted. 7/19/22 ES Sidewalk meets LS and ADA spec. 8/2/22 ES
Driveway Inspection Passed 7/25/2022 7/25/2022 08/02/2022
Misc
Informational
07/19/2022
Driveway was framed up with aggregate in and compacted. 7/19/22 ES Driveway meets LS and ADA spec. 8/2/22 ES
Occupancy Inspection - Codes Residential Failed 9/27/2022 9/27/2022 09/27/2022
Misc
Corrective Action Required
09/27/2022
- Pay all fees - Obtain an irrigation permit and submit a back flow certification - Label all non GFCI outlets - Address opening in master closet floor - Provide secondary lock on front door - Address opening in floor back bedroom closet - Address opening in floor front bedroom closet - Complete hardware on basement double exterior doors - Complete water heaters Bvent - Add anti hammer device at dishwasher - Provide spark rings at kitchen counter outlets - Seal exterior penetrations - Seal top of meter can and A/C disconnect - Splash blocks to discharge minimum of 36” away from foundation - Provide 6” clearance siding to grade - Lower water meter to 14-18” - Add gravel to water meter pit
All Rough Inspection - Residential Passed 9/27/2022 09/27/2022
Miscellaneous Correction
Resolved
09/27/2022
Erosion Control Inspection Residential Passed 9/27/2022 09/27/2022
Misc
Resolved
09/27/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 9/28/2022 9/29/2022 09/29/2022
Misc
Corrective Action Required
09/27/2022
- Pay all fees - Obtain an irrigation permit and submit a back flow certification - Seal top of meter can and A/C disconnect - Splash blocks to discharge minimum of 36” away from foundation - Provide 6” clearance siding to grade - Lower water meter to 14-18” - Add gravel to water meter pit TCO expiration 10/29/22
Occupancy Inspection - Codes Residential Temporary C of O 9/29/2022 09/29/2022
Misc
Corrective Action Required
09/29/2022
- Pay all fees TCO expiration 10/29/22
Occupancy Inspection - Codes Residential Failed 11/21/2022 11/21/2022
Misc
Corrective Action Required
09/29/2022
- Pay all fees - irrigation permit submit a back flow certification - Splash blocks to discharge minimum of 36” away from foundation - Provide 6” clearance siding to grade TCO expiration 10/29/22
Plot Plan Inspection Passed 01/27/2023
Occupancy Inspection - Codes Residential Failed 1/27/2023 01/27/2023
Misc
Corrective Action Required
11/21/2022
- Pay back TCO fees TCO expiration 10/29/22
Occupancy Inspection - Codes Residential Full C of O 2/1/2023 01/31/2023
Misc
Resolved
01/31/2023
- Pay back TCO fees TCO expiration 10/29/22
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 Application Form totta permit
07/12/2021 Application Form totta permit app
07/13/2021 Permit Codes Residential Plan Review
07/19/2021 Approved Plans Approved Drawings
07/27/2021 Plot Plan Approved Plot Plan
07/27/2021 Permit Codes Residential Plan Review
07/29/2021 Permit DS Building Permit
07/29/2021 Receipt Receipt for transaction:2021-006052
08/11/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter Stop Work Order
09/08/2021 Final_2021_06_24-07_01_HPiers_LSMO_Shaw
09/08/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter Stop Work Order
12/10/2021 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 2143 NW Killarney garage slab letter
03/17/2022 Master Hex Bay Engineering - 2143 NW Killarney Lane - Master Bedroom Letter
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/21/2022 2143 killarney rafters letter
03/22/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/29/2022 Receipt Receipt for transaction: 2022-007895
09/29/2022 Letter Codes Temporary Certificate of Occupancy
11/21/2022 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
01/30/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/30/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/30/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/31/2023 Letter Codes Final Certificate of Occupancy
01/31/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home