Summary
PRRES20213588
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW FOUR PLEX - UNFINISHED BASEMENT - UNCOVERED PATIO
07/12/2021
07/13/2021
01/08/2022
04/05/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,342.02 $3,342.02 Paid 07/13/2021
8331507-Sewer Connection Fee $30.00 $30.00 Paid 07/13/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 07/13/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 07/13/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2021
7232302-Residential Excise Tax Fee $4,308.48 $4,308.48 Paid 07/13/2021
8331504-EFHB Middle Big Creek, Full $1,607.04 $1,607.04 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 9/23/2021 9/23/2021 09/23/2021
Misc
Corrective Action Required
09/23/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed 9/23/2021 9/23/2021 09/23/2021
Misc
Corrective Action Required
09/23/2021
FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
Misc
Corrective Action Required
09/23/2021
THIRD PARTY ENGINEER REPORT REJECTED, INFORMATION INCOMPLETE, REQUIRED TO NOTE LOCATIONS OF UFER GROUNDS ON INSPECTION REPORT IN NOTES
Underslab Plumbing Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
Misc
Corrective Action Required
09/23/2021
3701 OK 3703,3705, 3707 SET INTERIOR DRAIN TILE
Footing Inspection - Residential Passed 09/28/2021
Misc
Informational
09/28/2021
APPROVED PER ALBERT P HERMANS 9/2/21
Underslab Plumbing Inspection - Residential Passed 10/1/2021 10/1/2021 10/01/2021
Misc
Informational
10/01/2021
3701,3703,3705,3707 OK
Sewer Service Inspection - R Partial 3/14/2022 (11:30) 3/14/2022 03/14/2022
Misc
Corrective Action Required
03/14/2022
3705 OK
Sewer Service Inspection - R Partial 3/16/2022 (10:30) 3/16/2022 03/16/2022
Misc
Corrective Action Required
03/14/2022
3705,3707 OK
Sewer Service Inspection - R Partial 3/17/2022 (9:30) 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/16/2022
3705,3707,3703 OK
Sewer Service Inspection - R Passed 3/17/2022 (2:30) 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
3705,3707,3703,3701 OK
Water Service Inspection - R Passed 3/24/2022 (2:00) 3/24/2022 03/24/2022
Erosion Control Inspection Residential Failed 3/24/2022 3/24/2022 03/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/30/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE PROVIDE GRAVEL FILTER CLEAN STREET OF MUD & GRAVEL
All Rough Inspection - Residential Not Ready 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/09/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Electrical Service Inspection Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/09/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/09/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Rated Assembly Inspection Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/09/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Electrical Service Inspection Failed 6/10/2022 6/10/2022 06/10/2022
Misc
Resolved
06/10/2022
Gas Service Inspection - Residential Failed 6/10/2022 6/10/2022 06/10/2022
Misc
Resolved
06/10/2022
All Rough Inspection - Residential Failed 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/09/2022
UNIT 3701: -(2) car garage requires (2) 20 amp receptacles -provide bocca protection plate at bottom plate pex for fridge -provide engineer report on floor joists above foyer overbored and over notched for DWV, field fix with metal strap -min 24” lap between dbl top plate breaks, see great room west wall -(2) trimmer studs at garage entry header per plans -(2) trimmer studs at kitchen/great room entry header per plans LBW -provide stud pack NE corner great room for girder truss bearing above per plans -solid shim all trimmer studs cut short of header -have engineer with truss manufacturer address A1 girder truss that has been sheared down against Lay in trusses -all truss hangers per plans -address floor joist bored less than 2” from end of joist for SE cable, bores for NM less than 2” apart -address floor joist bored for gas line less than 2” from end of joist -shield service panel from pex water line above -LIB bracing straps loose -attic soffit vents UNIT 3703: -(2) car garage requires (2) 20 amp receptacles -(2) trimmer studs at garage entry header per plans -(2) trimmer studs at kitchen/great room entry header per plans LBW -land NM electrical to box at garage furred down -provide bocca protection plate at DWV bottom plate garage wall/garage entry closet -provide stud shoe 1st floor powder bath stud lbw bored for DWV -Outlet for 2nd floor bath Incomplete -Gap in plywood at ridge within 4’ of firewall. -Protect romex within 6’ attic access. -provide engineer report on floor joists above foyer overbored and over notched for DWV, field fix with metal strap -address floor joist bored less than 2” from end of joist for SE cable, bores for NM less than 2” apart -Missing plate bolts Front of basement. -Gas line not run to furnace. -Missing firestopping second floor heat chase - Missing studs second-floor bathroom. -LIB bracing straps loose -attic ventilation soffit vents
Rated Assembly Inspection Failed 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/09/2022
3701 OK 3703 -Gap in plywood at ridge within 4’ of firewall.
Electrical Service Inspection Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/17/2022
- land GEC to neutral bar at service - provide addressed at disconnects and meters
Gas Service Inspection - Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/17/2022
UNIT 3701 OK UNITS 3703, 3705, 3707 COMPLETE GAS LINE INSTALL AT FURNACE
Rated Assembly Inspection Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/10/2022
3701 OK 3703 OK 3705 OK 3707: PROVIDE 4' FIRE RATED PLYWOOD AT ROOF DECK FIREWALL MASTER BEDROOM
All Rough Inspection - Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/10/2022
UNIT 3701: -(2) car garage requires (2) 20 amp receptacles, outlets need to be accessible at each bay, not just double box on one side of bay -all truss hangers per plans -address floor joist bored less than 2” from end of joist for SE cable, bores for NM less than 2” apart, nail off strap -address floor joist bored for gas line less than 2” from end of joist, engineer letter calls for 36” strap UNIT 3703: -(2) car garage requires (2) 20 amp receptacles, outlets need to be accessible at each bay, not just double box on one side of bay -Gas line not run to furnace. UNIT 3705: -(2) car garage requires (2) 20 amp receptacles, outlets need to be accessible at each bay, not just double box on one side of bay -anchor bolts shall be in middle third of sill plate garage -support all DWV every 48” oc -overnotched floor joist for DWV garage -2x10 at sliding glass door header split -provide (4) 2X stud pack at garage for 2nd floor girder truss bearing per plans -seal unused top plate bore 2nd floor bathroom -provide structural straps at master bath vanity top plate bores -shield electrical boxes at return air stud cavities -address broken truss master bed -complete gas lines at furnace UNIT 3707: -(2) car garage requires (2) 20 amp receptacles, outlets need to be accessible at each bay, not just double box on one side of bay -anchor bolts shall be in middle third of sill plate garage -provide 4’ fire rated plywood at roof deck to firewall master bed -missing stud bed#3 closet -provide structural straps at master bath vanity top plate bores -complete gas line at furnace -36” strap at gas line bored less than 2” from end of joist at basement
Gas Service Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/17/2022
UNIT 3701, 3703, 3705, 3707 OK
Rated Assembly Inspection Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/17/2022
3701 OK 3703 OK 3705 OK 3707: PROVIDE 4' FIRE RATED PLYWOOD AT ROOF DECK FIREWALL MASTER BEDROOM
Electrical Service Inspection Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/17/2022
- land GEC to neutral bar at service - provide addressed at disconnects and meters
All Rough Inspection - Residential Not Ready 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/17/2022
UNIT 3701: -all truss hangers per plans -address floor joist bored less than 2” from end of joist for SE cable, bores for NM less than 2” apart, (nail off strap) UNIT 3703: OK UNIT 3705: -support all DWV every 48” oc -overnotched floor joist for DWV garage -seal unused top plate bore 2nd floor bathroom -provide structural straps at master bath vanity top plate bores -address broken truss master bed UNIT 3707: -(2) car garage requires (2) 20 amp receptacles, outlets need to be accessible at each bay, not just double box on one side of bay -anchor bolts shall be in middle third of sill plate garage -provide 4’ fire rated plywood at roof deck to firewall master bed -missing stud bed#3 closet -provide structural straps at master bath vanity top plate bores -36” strap at gas line bored less than 2” from end of joist at basement
Rated Assembly Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Resolved
06/23/2022
Electrical Service Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Resolved
06/23/2022
All Rough Inspection - Residential Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/21/2022
UNIT 3701: OK TO INSULATE AND ROCK UNIT 3703: OK TO INSULATE AND ROCK UNIT 3705: -support all DWV every 48” oc -overnotched floor joist for DWV garage -address broken truss master bed *OK TO INSULATE* UNIT 3707: OK TO INSULATE AND ROCK
All Rough Inspection - Residential Passed 6/28/2022 6/28/2022 06/28/2022
Misc
Resolved
06/28/2022
Driveway Inspection Partial 8/1/2022 8/1/2022 08/01/2022
Misc
Informational
08/01/2022
8.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 8/1/2022 8/1/2022 08/01/2022
Misc
Informational
08/01/2022
8.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete
Erosion Control Inspection Residential Passed 3/20/2023 03/20/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/20/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/20/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE PROVIDE GRAVEL FILTER CLEAN STREET OF MUD & GRAVEL
Foundation Inspection - Commercial Passed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
Thyrd party inspection
Corrective Action Required
03/20/2023
Plot Plan Inspection Passed 3/20/2023 03/20/2023
Occupancy Inspection - Codes Residential Failed 3/20/2023 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
- Driveway inspection pending - Sidewalk inspection pending - Seal exterior penetrations on all - Anti tamper on all A/C compressors 3701 - Label non gfci at sump - Anti siphon on spigot at water main - Wire water heater - Add anchor to steel column basement - 3703 - Seal ceiling penetration in garage - Seal around water spigot in garage - Provide handrail to basement ( not ready) - Water main needs back flow preventer - Need second anchor in steel column basement - Steel I- beam in basement does not have 3” of support from pocket near panel - Wire water heater Inspection stopped with missing handrail 3705 and 3707 not inspected
Driveway Inspection Passed 3/20/2023 03/21/2023
Misc
Informational
08/01/2022
8.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete 3-21-23 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Failed 3/20/2023 03/21/2023
Misc
Informational
08/01/2022
8.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete 3-21-23 RH. There was a crack on one panel of concrete and it will need replaced.
Occupancy Inspection - Codes Residential Full C of O 4/5/2023 4/5/2023 04/05/2023
Misc
Resolved
04/05/2023
- Driveway inspection pending - Sidewalk inspection pending - Seal exterior penetrations on all - Anti tamper on all A/C compressors - Anti siphon on spigot at water main - 3703 - Seal ceiling penetration in garage 3705 and 3707 not inspected
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 OS #6 - PERMIT APP
07/12/2021 Approved Plans Approved Drawings
07/12/2021 Approved Plans Approved Truss Package
07/12/2021 Permit Codes Residential Plan Review
07/13/2021 Plot Plan Approved Plot Plan
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Permit DS Building Permit
07/13/2021 Receipt Receipt for transaction:2021-005593
09/02/2021 Approved Plans Approved Truss Layout
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 3701 SW WALSH DR FTG INSP
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/27/2021 3701 SW WALSH DR FTG INSP REV
09/28/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
01/27/2022 Approved Plans Approved Drawings
03/14/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/10/2022 6 osage letter #2
06/10/2022 6 osage letter
06/10/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/17/2022 Approved Plans Approved Truss Repair
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/24/2022 Approved Plans Approved Truss Repair
06/27/2022 Lot 6 Osage Field Issue Letter 3
06/28/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
10/28/2022 Receipt Receipt for transaction:2022-008582
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/21/2023 Letter INSPECTION SUMMARY
03/21/2023 Cracked Sidewalk
03/21/2023 Letter INSPECTION SUMMARY
04/05/2023 Letter Field Certificate of Occupancy
04/05/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home