Permit Application Status

PRRES20213323


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213323
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 07/28/2021 12:00 AM by username 'Mark Harding'. STOP WORK ORDER removed on 07/30/2021 12:00 AM by username 'Patrick Schonfeldt'.
06/28/2021
07/01/2021
12/26/2021
08/15/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,590.45 $1,590.45 Paid 07/01/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/01/2021
7232302-Residential Excise Tax Fee $2,154.24 $2,154.24 Paid 07/01/2021
8331507-Sewer Connection Fee $840.00 $840.00 Paid 07/01/2021
8331401-Water Tap Fee $7,162.00 $7,162.00 Paid 07/01/2021
8350015-Water Meter Fee $911.08 $911.08 Paid 07/01/2021
8331504-EFHB Middle Big Creek, Full $937.44 $937.44 Paid 10/22/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 06/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/26/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 7/23/2021 7/23/2021 07/23/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Failed - Stop Work 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/28/2021
no erosion contorl on the south side, damaged at the east side next to pryor road. and no erosion contrll in the front of the lot.
Erosion Control Inspection Residential Failed 7/28/2021 07/28/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. no erosion control in the front, south, and dmanged on the rear next to pryor.
Erosion Control Inspection Residential Passed 7/30/2021 7/30/2021 07/30/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/30/2021
Footing Inspection - Residential Passed 07/30/2021
Misc
Resolved
07/30/2021
Sewer Service Inspection - R Partial 8/9/2021 (1:00) 8/9/2021 08/09/2021
Misc
Informational
08/09/2021
3813 SEWER OK TO COVER
Sewer Service Inspection - R Passed 8/12/2021 (1:00) 8/12/2021 08/12/2021
Misc
Informational
08/09/2021
3813 AND 3811 SEWER OK TO COVER
Water Service Inspection - R Passed 8/19/2021 (1:00) 8/19/2021 08/19/2021
Erosion Control Inspection Residential Failed 8/19/2021 8/19/2021 08/19/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/19/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 9/17/2021 9/17/2021 09/17/2021
Misc
Corrective Action Required
09/17/2021
PLUMBING TRADES RECONFIGURING PLUMBING HEIGHTS ON 3811 AND 3813, RESCHEDULE WHEN COMPLETE
Underslab Plumbing Inspection - Residential Passed 9/21/2021 9/21/2021 09/21/2021
Misc
Resolved
09/21/2021
Gas Service Inspection - Residential Passed 3/2/2022 3/2/2022 03/02/2022
Erosion Control Inspection Residential Failed 3/2/2022 3/2/2022 03/02/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/19/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT PERIMETER, MAINTAIN GRAVEL FILTER WITH 6" LIFT OF 3/4' GRAVEL TO HOUSE, CLEAN DEBRIS FROM STREETS
Electrical Service Inspection Failed 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
03/02/2022
-PROVIDE UFER GROUNDS AT SERVICES -PROVIDE ADDRESSES AT METER CANS AND DISCONNECTS
Electrical Service Inspection Failed 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
03/02/2022
-PROVIDE UFER GROUNDS AT SERVICES -PROVIDE ADDRESSES AT METER CANS AND DISCONNECTS
Electrical Service Inspection Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/02/2022
-PROVIDE ADDRESSES AT METER CANS AND DISCONNECTS
All Rough Inspection - Residential Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/23/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -secure all breakaway clips at fire rock -repair any damaged sections of fire rock -rated fire separation wall required between units per plans design A7.0 at basement SE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -fireblock plumbing chase at garage entry -Fireblock deadspace at shower 1st floor -Install all windows -H2.5 truss hold down or equivalent at all hip trusses -12” oc nailing at all abutting and intersecting wall corners -security blocking at front door -(3) 2x10 joists connect to trpl lvl beam at garage per plans -(3) 2x4 stud pack at dbl lvl garage wall per plans -(2) 2x4 trimmer studs at garage entry door per plans -attic access required at garage per plans -attic access required for 1st floor attic space -(4) 2x4 stud pack at all girder truss bearing ends per plans -(2) 2x4 trimmer studs at front entry per plans -all truss hangers per plans -solid block sheathing breaks 2nd floor -secure wiring 2nd floor bedroom -fireblock at top plate between furring strips at 2nd floor stair wall -rear north corner at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together -add stud at 2x6 wall end top plate at steel beam stud pack, right of basement sliding glass door -secure SE cable above service panel -cap and label future vent at basement -LIB bracing at basement wall per plans -(2) 2x6 trimmers at basement sliding glass door per plans -(2) 2x6 trimmer studs at basement window per plans -CS-PF per plans at great room window, nail exterior sheathing per design UNIT 3813: -address studs over notched at left side garage portal corner for electrical, studs short of plate at right side of portal -land electrical to box at garage ceiling -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -secure all breakaway clips at fire rock -repair any damaged sections of fire rock -breakaway clips required per design spacing, see A7.0, see 2nd floor -H stud required at fire rock breaks, see A7.0, see 2nd floor -rated fire separation wall required between units per plans design A7.0 at basement NE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -fireblock plumbing chase at garage entry -dbl top plate requires min 24” offset between plate breaks - see laundry, garage south wall -Fireblock deadspace at shower 1st floor -H2.5 truss hold down or equivalent at all hip trusses -12” oc nailing at all abutting and intersecting wall corners -security blocking at front door -attic access required at garage per plans -attic access required for 1st floor attic space -(4) 2x4 stud pack at all girder truss bearing ends per plans -all truss hangers per plans -(3) 2x4 stud pack at dbl lvl garage wall per plans -(2) 2x4 trimmer studs at garage entry door per plans -(2) 2x4 trimmer studs at front entry door per plans -CS-PF bracing per plans at great room windows, nail exterior sheathing per design -install window 2nd floor -LIB bracing locations per plans 2nd floor -rear south corner at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together -add stud at 2x6 wall end top plate at steel beam stud pack, left of basement sliding glass door -secure SE cable above service panel -shield service panel from pex water line directly above -cap and label future vent at basement -(2) 2x6 trimmers at basement sliding glass door per plans -(2) 2x6 trimmer studs at basement window per plans -LIB bracing at basement wall per plans
Rated Assembly Inspection Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/23/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -secure all breakaway clips at fire rock -repair any damaged sections of fire rock -rated fire separation wall required between units per plans design A7.0 at basement SE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail UNIT 3813: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -secure all breakaway clips at fire rock -repair any damaged sections of fire rock -breakaway clips required per design spacing, see A7.0, see 2nd floor -H stud required at fire rock breaks, see A7.0, see 2nd floor -rated fire separation wall required between units per plans design A7.0 at basement NE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail
All Rough Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/23/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -repair any damaged sections of fire rock -rated fire separation wall required between units per plans design A7.0 at basement SE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -fireblock plumbing chase at garage entry, (seal the annular space around plumbing) -12” oc nailing at all abutting and intersecting wall corners (see great room) -security blocking at front door (solid block at all hinges) -attic access required for 1st floor attic space (attic access required 30” vertical clearance) -protect all NM within 6’ of attic entrance -land all NM to boxes and secure electrical boxes 1st floor bed closet and bath -Have engineer with truss manufacture address C5 gable truss that has been cut and repair with 2x4 scabs, 2nd floor south wall -rear north corner at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together -cap and label future vent at basement -CS-PF per plans at great room window, nail exterior sheathing per design UNIT 3813: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -repair any damaged sections of fire rock -breakaway clips required per design spacing, see A7.0, see 2nd floor -fireblock between top plate and fire rock at 2nd floor -rated fire separation wall required between units per plans design A7.0 at basement NE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -address studs over notched at garage portal corners for electrical -land electrical to box at garage ceiling -fireblock plumbing chase at garage entry (fireblock annular space around plumbing) -12” oc nailing at all abutting and intersecting wall corners (see great room) -security blocking at front door (solid blocking required at each hinge) -attic access required for 1st floor attic space (attic access requires 30” vertical clearance) -secure all electrical at 1st bath -land electrical to box at first floor bedroom wall -Have engineer with truss manufacturer address A1 truss and C5 gable truss that have been repaired with 2x4 scabbed -CS-PF bracing per plans at great room windows, nail exterior sheathing per design -rear south corner at daylight wall in basement, bottom plate and (3) studs at corner nailed 12” oc together -shield service panel from pex water line directly above -cap and label future vent at basement -(2) 2x6 trimmers at basement sliding glass door per plans, trimmers need to be full bearing
Rated Assembly Inspection Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/23/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -repair any damaged sections of fire rock -rated fire separation wall required between units per plans design A7.0 at basement SE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail UNIT 3813: -fire rated plywood required within 4’ of firewall -steel C runner cap required at top of fire rated rock against roof deck, see detail page A7.0 plans -repair any damaged sections of fire rock -breakaway clips required per design spacing, see A7.0, see 2nd floor -fireblock between top plate and fire rock at 2nd floor -rated fire separation wall required between units per plans design A7.0 at basement NE corner -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail
Erosion Control Inspection Residential Partial 3/29/2022 3/29/2022 03/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/29/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT PERIMETER, MAINTAIN GRAVEL FILTER WITH 6" LIFT OF 3/4' GRAVEL TO HOUSE, CLEAN DEBRIS FROM STREETS
Misc
Corrective Action Required
03/29/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Electrical Service Inspection Passed 4/5/2022 4/5/2022 04/05/2022
Misc
Resolved
04/05/2022
All Rough Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
03/29/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -see garage -repair any damaged sections of fire rock -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -security blocking at front door (solid block at all hinges) -cap and label future vent at basement UNIT 3813: -fire rated plywood required within 4’ of firewall - see garage -repair any damaged sections of fire rock -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail -Have engineer with truss manufacturer address A1 truss that has been repaired with 2x4 scabbed -shield service panel from pex water line directly above -cap and label future vent at basement
Rated Assembly Inspection Failed 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
03/29/2022
UNIT 3811: -fire rated plywood required within 4’ of firewall -see garage -repair any damaged sections of fire rock -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail UNIT 3813: -fire rated plywood required within 4’ of firewall - see garage -repair any damaged sections of fire rock -Fire caulk fire wall penetrations by SE cable at basement, Refer to A7.1 for detail
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/05/2022
UNIT 3811: **OK** UNIT: 3813 -Have engineer with truss manufacturer address A1 truss that has been repaired with 2x4 scabbed **OK TO INSULATE**
Rated Assembly Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Misc
Resolved
04/07/2022
All Rough Inspection - Residential Passed 4/8/2022 4/8/2022 04/08/2022
Misc
Resolved
04/08/2022
**OK TO INSULATE**
Driveway Inspection Partial 4/14/2022 4/14/2022 04/14/2022
Misc
Informational
04/14/2022
On 4.14.2022 I performed a driveway inspection and passed the subgrade for pouring concrete.
Sidewalk Inspection Partial 4/14/2022 4/14/2022 04/14/2022
Misc
Informational
04/14/2022
On 4.14.2022 I performed A sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 5/6/2022 5/6/2022 05/06/2022
Misc
Informational
04/14/2022
On 4.14.2022 I performed a driveway inspection and passed the subgrade for pouring concrete.
Sidewalk Inspection Passed 5/6/2022 5/6/2022 05/06/2022
Misc
Informational
04/14/2022
On 4.14.2022 I performed A sidewalk inspection and pass the subgrade to pour concrete
Water Service Inspection - R Passed 6/16/2022 06/16/2022
Water Service Inspection - R Passed 6/16/2022 06/16/2022
Occupancy Inspection - Codes Residential Failed 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/16/2022
CORRECTIONS FOR BOTH UNIT 3811 AND 3813 -resolve all outstanding inspection fees -Provide permanent address labels at meter can and disconnect -support deck beams -splash blocks all downspouts and sump pump locations, min 36" discharge from foundation UNIT 3811 OK FOR TCO, TCO EXPIRES 7/1/22** UNIT 3813: NO OCCUPANCY INSPECTION PERFORMED, CORRECTING SEWER AT TIME OF INSPECTION, PROVIDE ADDRESS
Occupancy Inspection - Codes Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/16/2022
CORRECTIONS FOR BOTH UNIT 3811 AND 3813 -resolve all outstanding inspection fees -Provide permanent address labels at meter can and disconnect -support deck beams -splash blocks all downspouts and sump pump locations, min 36" discharge from foundation UNIT 3811 OK FOR TCO, TCO EXPIRES 7/19/22** UNIT 3813: NO OCCUPANCY INSPECTION PERFORMED, CORRECTING SEWER AT TIME OF INSPECTION, PROVIDE ADDRESS
Occupancy Inspection - Codes Residential Failed 6/30/2022 6/30/2022 06/30/2022
Misc
Corrective Action Required
06/28/2022
CORRECTIONS FOR BOTH UNIT 3811 AND 3813 -maintain erosion control on lot until sod is placed -final grade and sod -Provide permanent address labels at meter can and disconnect -splash blocks all downspouts and sump pump locations, min 36" discharge from foundation UNIT 3811 OK FOR TCO, TCO EXPIRES 7/19/22** UNIT 3813: -handrail required at front stairs -garage door must be self closing -garage outlets not more than 5.5’ AFF -tempered glass required at windows great room east wall, right of sliding glass door -AFCI protection all breaker locations ever code -max AC overcurrent protection 25 amps
Erosion Control Inspection Residential Failed 6/30/2022 6/30/2022 06/30/2022
Misc
Corrective Action Required
03/29/2022
-maintain erosion control on lot until sod is placed
Occupancy Inspection - Codes Residential Ready for Temp CO 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
06/30/2022
-Provide permanent address labels at meter can and disconnect -connect sewer tracer wire to box at grade UNIT 3811 OK FOR TCO, TCO EXPIRES 7/19/22** -Sump pump extension, min 36” discharge from foundation UNIT 3813: -correct grade south side, negative slope towards foundation -Sump pump extension
Occupancy Inspection - Codes Residential Temporary C of O 07/26/2022
Misc
Corrective Action Required
07/20/2022
-Provide permanent address labels at meter can and disconnect -connect sewer tracer wire to box at grade UNIT 3811 OK FOR TCO, TCO EXPIRES 7/19/22** -Sump pump extension, min 36” discharge from foundation UNIT 3813: -correct grade south side, negative slope towards foundation -Sump pump extension
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/26/2022
-Provide permanent address labels at meter can and disconnect -connect sewer tracer wire to box at grade UNIT 3811 OK FOR TCO, TCO EXTENSION REQUEST, REC AND APPROVED 8/2/22** -Sump pump extension, min 36” discharge from foundation UNIT 3813: -correct grade south side, negative slope towards foundation -Sump pump extension
Occupancy Inspection - Codes Residential Temporary C of O 08/03/2022
Misc
Corrective Action Required
08/02/2022
-Provide permanent address labels at meter can and disconnect -connect sewer tracer wire to box at grade UNIT 3811 OK FOR TCO, TCO EXTENSION REQUEST, REC AND APPROVED 8/2/22** -Sump pump extension, min 36” discharge from foundation UNIT 3813: -correct grade south side, negative slope towards foundation -Sump pump extension
Occupancy Inspection - Codes Residential Failed 8/11/2022 8/11/2022 08/11/2022
Misc
Corrective Action Required
08/03/2022
-connect sewer tracer wire to box at grade UNIT 3813: -correct grade south side, negative slope towards foundation , fix sod and grade with holes and negative fall toward house.
Plot Plan Inspection Passed 08/15/2022
Erosion Control Inspection Residential Passed 08/15/2022
Misc
Resolved
08/15/2022
-maintain erosion control on lot until sod is placed
Occupancy Inspection - Codes Residential Full C of O 8/15/2022 8/15/2022 08/15/2022
Misc
Resolved
08/15/2022
Documents & Images
Date Uploaded File Type Document Name
06/28/2021 OS #24 - PERMIT APP
06/29/2021 Permit Codes Residential Plan Review
06/30/2021 Approved Plans Approved Truss Layout
06/30/2021 Approved Plans Approved Truss Package
06/30/2021 Permit Codes Residential Plan Review
07/01/2021 Permit DS Building Permit
07/01/2021 Receipt Receipt for transaction:2021-005266
07/23/2021 Letter INSPECTION SUMMARY
07/26/2021 M L Crose 3811 & 3813 SW Walsh Dr LSMO Twin Honedew Lot 24 P 2021-3323 3rd Party Footing Inspection Report 7-23-21
07/28/2021 Letter Stop Work Order
07/28/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
01/27/2022 Approved Plans Approved Drawings
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/31/2022 Approved Plans Approved Truss Repair
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/07/2022 2714890 A1 REP 04072022
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Receipt Receipt for transaction:2022-005205
06/29/2022 LOT 24 MINOR PLAT SEAL
06/30/2022 Plot Plan Approved Plot Plan
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/19/2022 24 Osage Letter
07/26/2022 Receipt Receipt for transaction:2022-006086
07/26/2022 Letter Codes Temporary Certificate of Occupancy
08/02/2022 Letter OS 24 A and B Extension Request Form
08/03/2022 Receipt Receipt for transaction:2022-006327
08/03/2022 Letter Codes Temporary Certificate of Occupancy
08/11/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter Codes Final Certificate of Occupancy
08/15/2022 Letter Field Certificate of Occupancy
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home