Summary
PRRES20212723
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
05/25/2021
07/12/2021
05/24/2022
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
Julie Pitts, Address:10707 Indiana Ave  
NZVACEK@GMAIL.COM  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/12/2021
9110078-Valuation Fee New Single Family $1,245.64 $1,245.64 Paid 07/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 07/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/23/2021 (9:45) 7/23/2021 07/23/2021
Water Service Inspection - R Partial 7/23/2021 (9:45) 7/23/2021 07/23/2021
Footing Inspection - Residential Passed 07/23/2021
Informational
07/23/2021
FOOTING APPROVED BY ENGINEER
Water Service Inspection - R Passed 7/26/2021 07/26/2021
Erosion Control Inspection Residential Failed 7/27/2021 07/27/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/27/2021
-COMPLETE DRAIN TILE TO SUMP PUMP -POST ADDRESS UNDERSLAB PLUMBING OK
Footing Inspection - Residential Failed 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
THE FOOTING WAS APPROVED BY ENGINEER, BUT I SAW THAT A COLUMN PAD IS MISSING AT STAIR
Underslab Plumbing Inspection - Residential Failed 7/29/2021 07/29/2021
Misc
Informational
07/29/2021
**UNDERSLAB PLUMBING OK **THE FOOTING APPROVED BY YOUR ENGINEER BUT A COLUMN PAD IS MISSING. SCHEDULE FOR A FOOTING INSPECTION WHEN READY **HAVE THE EROSION CONTROL FIXED FOR THE NEXT FOOTING INSPECTION
Footing Inspection - Residential Passed 08/04/2021
Misc
Resolved
08/04/2021
THE FOOTING WAS APPROVED BY ENGINEER, BUT I SAW THAT A COLUMN PAD IS MISSING AT STAIR
Underslab Plumbing Inspection - Residential Passed 8/4/2021 8/4/2021 08/04/2021
Misc
Resolved
08/04/2021
**UNDERSLAB PLUMBING OK **THE FOOTING APPROVED BY YOUR ENGINEER BUT A COLUMN PAD IS MISSING. SCHEDULE FOR A FOOTING INSPECTION WHEN READY **HAVE THE EROSION CONTROL FIXED FOR THE NEXT FOOTING INSPECTION
Water Service Inspection - R Passed 9/3/2021 09/03/2021
Misc
Informational
09/03/2021
service passed 7-26-21
Piers/Caissons Inspection - Residential Passed 10/8/2021 (9:00) 10/8/2021 10/08/2021
Electrical Service Inspection Passed 10/27/2021 10/27/2021 10/27/2021
Gas Service Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
10/27/2021
No pressure
All Rough Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
10/27/2021
-Nail exterior siding per code -Anchor garage column with two 1/2” bolts -Install the garage PFH strap on the inner side of portal wall or put more nailing into the h-frame-lvl area -Install joist hangers above mud closet -Cut out top plate for return air at mud/stair wall. Strap top plates -Fb duct chase and wall around master shower from ceiling space -Water lines in laundry located outside wall space -Support joist at master closet/garage return air space wall at corner -Over notched joist at tub trap above&outside master closet -Protect water lines at master shower -Header off cut joist above master shower -Fb opening at master toilet/bedroom wall (where 3” pvc is at) ; fb back side of fireplace space and bedroom wall from roof. Fb material at top lid of fireplace shall be 3/4” sheathing, not 1/2” -Install deck door per security code -Nail hangers above kitchen area -Protect refrigerator water line -Strap all top plates of exterior wall and interior bearing wall where bored more than 50% -Provide engineer address for the triple 2x10 header above slide door not per plan -Block off rest of 2nd fl wall unused stud space from return air space -Install collar ties near ridges per code -Install ceiling fan/light box at 2nd fl bedroom -Fb 2nd fl duct chase from roof -Solid block underneath roof lvl beam point load. Install min 2 studs continuous down to I beam in basement -Pan off return air space (rear basement bedroom) from soffit and ceiling space -Fb basement bedroom walls from ceiling space throughout -Header off cut joist at main duct -Complete plumbing to master bathroom tub -Block at cantilevered joists **OK TO INSULATE
Gas Service Inspection - Residential Passed 11/12/2021 11/12/2021 11/12/2021
Misc
Resolved
11/12/2021
No pressure
All Rough Inspection - Residential Failed 11/12/2021 11/12/2021 11/12/2021
Misc
Corrective Action Required
10/27/2021
-Nail exterior siding per code -Cut out top plate for return air at mud/stair wall. Strap top plates-strap 6" each way with (4) 10d nails each side -Fb duct chase and wall around master shower from ceiling space -Support joist at master closet/garage return air space wall at corner -add stud -Over notched joist at tub trap above&outside master closet -Header off cut joist above master shower-Nail hanger -Fb opening at master toilet/bedroom wall (where 3” pvc is at) ; fb back side of fireplace space and bedroom wall from roof. -Install deck door per security code -Nail hangers above kitchen area -Strap all top plates of exterior wall and interior bearing wall where bored more than 50%-strap 6" past each direction with (4) 10d nails each side -Provide engineer address for the triple 2x10 header above slide door not per plan -Install collar ties near ridges per code -Fb 2nd fl duct chase from roof -Solid block underneath roof lvl beam point load. Install min 2 studs continuous down to I beam in basement -Fb basement bedroom walls from ceiling space throughout -Header off cut joist at main duct -Complete plumbing to master bathroom tub **OK TO INSULATE
All Rough Inspection - Residential Not Ready 11/15/2021 11/15/2021 11/15/2021
Misc
Corrective Action Required
11/12/2021
-Fb duct chase and wall around master shower from ceiling space -Support joist at master closet/garage return air space wall at corner -Over notched joist at tub trap above&outside master closet **Nail joist hanger and complete re-installing plumbing -Fb opening at master toilet/bedroom wall , where 3” pvc is at. **also move the return air grill to correct location -Install deck door per security code **reinstall the vapor barrier -Nail hangers above kitchen area **at ceiling beam connection -Strap all top plates of exterior wall and interior bearing wall where bored more than 50%-strap 6" past each direction with (4) 10d nails each side -Fb 2nd fl duct chase from roof **Fb gap -Solid block underneath roof lvl beam point load. Install min 2 studs continuous down to I beam in basement -Fb basement bedroom walls from ceiling space throughout -Header off cut joist at main duct -Complete plumbing to master bathroom tub **OK TO INSULATE **11/15-REINSPECTION FEE ASSESSED
All Rough Inspection - Residential Passed 12/9/2021 12/9/2021 12/09/2021
Misc
Informational
12/09/2021
**OK TO ROCK **11/15-REINSPECTION FEE ASSESSED
Driveway Inspection Partial 2/11/2022 02/11/2022
Misc
Informational
02/11/2022
2-11-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Partial 2/18/2022 2/18/2022 02/15/2022
Misc
Informational
02/11/2022
2-11-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 2/25/2022 2/25/2022 02/28/2022
Misc
Informational
02/15/2022
2-11-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
02/28/2022
2-28-22 driveway looks good and has expansion joints at curb and right of way also meets ADA spec
Sidewalk Inspection Partial 2/25/2022 2/25/2022 02/28/2022
Misc
Informational
02/28/2022
AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 02/28/2022
Misc
Informational
02/28/2022
AN forms are in place and aggregate is present and compacted
Misc
Informational
02/28/2022
2-28-22 AN sidewalk looks good and meets Ada spec
Erosion Control Inspection Residential Passed 05/10/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/10/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 5/10/2022 5/10/2022 05/10/2022
Misc
Corrective Action Required
05/10/2022
**No access to house. Tried to call Jeff but phone call not answered -A not-ready fee assessed on 11/12/21 has not been paid -Sewer manhole at front is buried -As-graded plot plan is required prior to sodding -Swale at the rear of lot is not graded per plot plan. Provide swale per plan -Final grade, sod, downspout and sump pump extension -Fix sunken grade at rear corner of house -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade **No inspection made inside
Occupancy Inspection - Codes Residential Failed 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
05/10/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city. Where’s the backflow preventer valve? -A not-ready fee assessed on 11/12/21 has not been paid -Sewer manhole at front is buried -As-graded plot plan is required -Swale at the rear of lot is not graded per plot plan. Provide swale grading per plan -Final grade, sod, downspout and sump pump extension -Fix sunken grade at rear corner of house -Provide sewer tracer wire port at grade -Pendant light not allowed within the master bathroom tub zone -Fb bottom of garage boxed out walls -Change out sconce light above stair to allowed min 6’8” of headroom clearance or luminaire not extruding more than 4” from wall -Install box extensions for receptacle boxes at wet bar -Cut ufer rebar to safe height -Provide breaker lock for oven; label missing for slot 21-23 breaker (water heater)
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/16/2022
-Sod
Plot Plan Inspection Passed 5/23/2022 05/23/2022
Occupancy Inspection - Codes Residential Full C of O 5/24/2022 5/24/2022 05/24/2022
Misc
Resolved
05/24/2022
-Sod
Documents & Images
Date Uploaded File Type Document Name
05/25/2021 Blue prints
05/25/2021 Lot 111 Plot Plan
05/25/2021 Application Form APPLICATION
05/25/2021 Application Form excise tax
05/27/2021 Approved Plans APPROVED PLOT PLAN
05/27/2021 Permit Codes Residential Plan Review
07/12/2021 Permit DS Building Permit
07/12/2021 Receipt Receipt for transaction: 2021-005548
07/12/2021 M L Crose 4713 NE Freehold Dr LSMO Monticello Lot 111 3rd Party Footing Inspection Report 7-12-21
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/21/2021 Approved Plans approved plans
10/08/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/17/2022 Receipt Receipt for transaction:2022-003512
05/20/2022 Letter Codes Temporary Certificate of Occupancy
05/20/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
05/23/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter Codes Final Certificate of Occupancy
05/24/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home