Summary
PRRES20212478
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED PATIO
05/14/2021
05/17/2021
11/10/2021
06/24/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/17/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/17/2021
9110078-Valuation Fee New Single Family $991.85 $991.85 Paid 05/17/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/17/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/17/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 05/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/4/2021 (1:45) 6/4/2021 06/04/2021
Underslab Plumbing Inspection - Residential Passed 7/6/2021 7/6/2021 07/06/2021
Sewer Service Inspection - R Passed 7/8/2021 (10:45) 7/8/2021 07/08/2021
Water Service Inspection - R Passed 7/9/2021 (11:15) 7/9/2021 07/09/2021
Erosion Control Inspection Residential Failed 7/9/2021 7/9/2021 07/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Partial 8/31/2021 8/31/2021 08/31/2021
Misc
Informational
08/31/2021
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Electrical Service Inspection Passed 12/9/2021 12/9/2021 12/09/2021
Gas Service Inspection - Residential Failed 12/9/2021 12/9/2021 12/09/2021
Misc
Corrective Action Required
12/09/2021
GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 12/9/2021 12/9/2021 12/09/2021
Misc
Informational
08/31/2021
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Misc
Corrective Action Required
12/09/2021
-Truss hold downs at all truss ends, structural screws must drive into truss through both top plates -address overbored stud for SE cable at south garage wall, master bed closet -nail all truss girders together per plans -address exterior walls not tied together at top plates- see garage west, front entry -pan off cantilever at garage -protect all NM within 6’ of attic access garage -30” vertical clearance required at attic access -secure all vertical DWV 2” or less at mid point -Dbl top plate requires min 24” offset between plate breaks- see front bedroom 1st floor -seal all top plate penetrations -Install sliding glass door -secure gas flex line at fireplace -address all Jack studs cut short of headers throughout -fireblock below top plate master bedroom closet, open to eave -unable to inspect trusses covered patio due to cover -Nail protection plates all NM 1 1/4” or less from end of stud -Bocca protection plate top plate wet bar -solid block between joists at cantilevers -complete discharge duct at basement bath exhaust fan -protection plate basement bath DWV -fireblock vertical to horizontal at furred down soffit ends basement bedroom -support DWV 48” oc basement bedroom -solid block between joists at beam open cavities, lateral restraint, basement bedroom/mechanical -connect flat 2x4 at basement furred downs to ceiling joists above to support ceiling load -address studs removed at stair wall for HVAC return air basement den, load bearing wall
All Rough Inspection - Residential Not Ready 12/17/2021 12/17/2021 12/17/2021
Misc
Informational
12/09/2021
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Misc
Corrective Action Required
12/09/2021
-Truss hold downs at all truss ends, structural screws must drive into truss through both top plates-hip truss in garage, hip truss front bed,truss m5 in north wall bath at dwv, behind shower, missing at M16 above slider, C9 at master -address overbored stud for SE cable at south garage wall, -address exterior walls not tied together at top plates- see garage west, front entry -protect all NM within 6’ of attic access garage -seal all top plate penetrations-lv by fireplace, -Install sliding glass door -secure gas flex line at fireplace -unable to inspect trusses covered patio due to cover -solid block between joists at cantilevers-INSULATE FIRST -complete discharge duct at basement bath exhaust fan-Connect bath exhaust -protection plate basement bath DWV -fireblock vertical to horizontal at furred down soffit ends basement bedroom-SEAL GAPS -support DWV 48” oc basement bedroom -connect flat 2x4 at basement furred downs to ceiling joists above to support ceiling load -address studs removed at stair wall for HVAC return air basement den, load bearing wall
All Rough Inspection - Residential Failed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
12/17/2021
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Misc
Corrective Action Required
12/17/2021
-address overbored stud for SE cable at south garage wall, FIX TO ENGINEERED LETTER SPECIFICATIONS -Install sliding glass door -unable to inspect trusses covered patio due Okay to insulate
Erosion Control Inspection Residential Failed 1/13/2022 01/13/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/13/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN UP DEBRIS FROM CURB
All Rough Inspection - Residential Failed 1/13/2022 1/13/2022 01/13/2022
Misc
Informational
01/05/2022
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Misc
Corrective Action Required
01/05/2022
-ADDRESS OVERBORED STUD FOR SE CABLE IN GARAGE MUST BE FIXED TO ENGINEER LETTER REQUIRMENTS -Install sliding glass door Okay to insulate
Gas Service Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Misc
Resolved
01/18/2022
GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Misc
Informational
01/13/2022
-GARAGE PORTAL EXTERIOR ONLY OK TO COVER
Misc
Corrective Action Required
01/18/2022
-Install sliding glass door Okay to insulate
Driveway Inspection Passed 3/24/2022 3/24/2022 03/25/2022
Misc
Informational
03/25/2022
On Thursday, 3-24-2022 a driveway inspection was completed and the driveway was passed to pour concrete.
Sidewalk Inspection Passed 3/24/2022 3/24/2022 03/25/2022
Misc
Informational
03/25/2022
On Thursday 3-24-2022 a sidewalk inspection was performed and passed inspection for concrete placement.
Occupancy Inspection - Codes Residential Failed 4/4/2022 4/4/2022 04/04/2022
Misc
Corrective Action Required
04/04/2022
inspection denied erosion control not in compliance Mitchell Schwarz 04/04/2022 8:47 AM
Erosion Control Inspection Residential Failed 4/4/2022 04/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/04/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN UP DEBRIS FROM CURB
DCM5 ESC INSP DENIED
Corrective Action Required
04/04/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Mitchell Schwarz 04/04/2022 8:49 AM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/04/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 04/04/2022 8:49 AM
Occupancy Inspection - Codes Residential Failed 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/04/2022
DOOR LOCKED, NO LOCK BOX CODE PROVIDED, PROVIDE LOCK BOX CODE WHEN SCHEDULING OR LEAVE DOOR UNLOCKED TO ALLOW FOR ACCESS, NO INTERIOR INSPECTION PERFORMED ONLY EXTERIOR EXTERIOR CORRECTIONS: -submit as graded plot Plan for review and approval -resolve outstanding inspection fees -obtain lawn irrigation system permit -final grade and sod -splash blocks all downspout and sump pump locations, maintain min 36” clearance from foundation -address numbers on house color must contrast against background color -install tamper resistant caps at AC compressor
Occupancy Inspection - Codes Residential Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/11/2022
-Sheet rock bottom of furout in garage -Provide access to whirpool tub pump per P2707 -Faulty GFCI at master vanity -Support expansion tank at hot water heater per P308.10 -submit as graded plot Plan for review and approval -resolve outstanding inspection fees -obtain lawn irrigation system permit -final grade and sod -splash blocks all downspout and sump pump locations, maintain min 36” clearance from foundation -address numbers on house color must contrast against background color -install tamper resistant caps at AC compressor
Occupancy Inspection - Codes Residential Failed 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/13/2022
- sod (check siding from grade at time of side) -address numbers on house color must contrast against background color
Plot Plan Inspection Passed 4/19/2022 04/19/2022
Occupancy Inspection - Codes Residential Temporary C of O 4/20/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/19/2022
TCO UNTIL 5/3/22 - sod (check siding from grade at time of side)
Piers/Caissons Inspection - Residential Passed 4/29/2022 04/29/2022
Erosion Control Inspection Residential Passed 4/29/2022 04/29/2022
DCM5 ESC INSP DENIED
Corrective Action Required
04/04/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Mitchell Schwarz 04/04/2022 8:49 AM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/04/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 04/04/2022 8:49 AM
Occupancy Inspection - Codes Residential Failed 4/29/2022 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/19/2022
TCO UNTIL 5/3/22 -address siding from ground
Occupancy Inspection - Codes Residential Failed 5/17/2022 05/17/2022
Misc
Corrective Action Required
04/29/2022
TCO Extended until 6/17/22 Mitchell Schwarz 05/17/2022 7:16 AM TCO UNTIL 5/3/22 -address siding from ground
Misc
Corrective Action Required
05/17/2022
TCO Extended
Occupancy Inspection - Codes Residential Failed 6/17/2022 06/17/2022
Misc
Corrective Action Required
05/17/2022
TCO Extended until 6/17/22 Mitchell Schwarz 05/17/2022 7:16 AM TCO UNTIL 5/3/22 -address siding from ground
Misc
Corrective Action Required
05/17/2022
TCO Extended
Misc
Informational
06/17/2022
Spoke with Tyler with Summit Homes and has requested a TCO Extension to finish items TCO Extension until 7/6/22
Occupancy Inspection - Codes Residential Full C of O 6/24/2022 6/24/2022 06/24/2022
Misc
Resolved
06/24/2022
TCO Extended until 6/17/22 Mitchell Schwarz 05/17/2022 7:16 AM TCO UNTIL 5/3/22 -address siding from ground
Misc
Resolved
06/24/2022
TCO Extended
Misc
Resolved
06/24/2022
Spoke with Tyler with Summit Homes and has requested a TCO Extension to finish items TCO Extension until 7/6/22
Documents & Images
Date Uploaded File Type Document Name
05/14/2021 HT #154 - PERMIT APP
05/14/2021 Approved Plans Approved Drawings
05/14/2021 Approved Plans Approved Truss Layout
05/14/2021 Approved Plans Approved Truss Package
05/14/2021 Permit Codes Residential Plan Review
05/17/2021 Permit Codes Residential Plan Review
05/17/2021 Permit DS Building Permit
05/17/2021 Receipt Receipt for transaction:2021-003088
05/21/2021 Plot Plan Approved Plot Plan
06/04/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
01/03/2022 154 Hawthorne Ridge over bored stud
01/05/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/18/2022 Plot Plan Approved As Graded Plot Plan
04/18/2022 Receipt Receipt for transaction:2022-002156
04/19/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter Codes Temporary Certificate of Occupancy
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter Codes Final Certificate of Occupancy
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home