Summary
PRRES20212031
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - FINISHED AND UNFINISHED BASEMENT - COVERED DECK - PROPOSED WALKOUT WALKUP
04/26/2021
04/29/2021
10/25/2021
07/07/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
CURTIS@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Rejected 04/30/2021 04/28/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
04/28/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 04/30/2021 04/28/2021
Brandon Kalwei
Residential Plan Review Approved 04/30/2021 04/28/2021
Brandon Kalwei
03 Two (2) plot plans
Corrective Action Required
04/28/2021

Two (2) plot plans
Plot Plan Review Rejected 04/30/2021 04/28/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
04/28/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,115.11 $1,115.11 Paid 04/29/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 04/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/27/2021 05/27/2021
Misc
Informational
05/27/2021
Please post site address
Underslab Plumbing Inspection - Residential Passed 6/11/2021 6/11/2021 06/10/2021
Sewer Service Inspection - R Passed 6/16/2021 (8:15) 6/16/2021 06/16/2021
Water Service Inspection - R Passed 6/16/2021 (11:00) 6/16/2021 06/16/2021
Piers/Caissons Inspection - Residential Passed 7/12/2021 (1:00) 7/12/2021 07/12/2021
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Passed 2/18/2022 2/18/2022 02/18/2022
Gas Service Inspection - Residential Passed 2/18/2022 2/18/2022 02/18/2022
All Rough Inspection - Residential Failed 2/18/2022 2/18/2022 02/18/2022
Miscellaneous Correction
Corrective Action Required
02/18/2022
- Complete nailing portal frame lower third - Nail exterior siding to code - Fire block sheeting garage at laundry - Nail all intersecting corners 12” O C - Strap top plate intersecting corner of bedroom 2 and entry - H2.5 s attached to blocks from rafters over tub near bathroom 2 - Fire block gap in sheeting above stairs ( ceiling transition) - Add stud under double LVL kitchen and corner of stairs - Provide fire place - Install fire place vent - Fire block penetration plenum space master bedroom behind fire place - Fire block gaps in sheeting to joist master bathroom - Bathroom vents not complete - Provide longer straps and nail correctly around window at dining - Nail hangers double LVL near dining bump out - No fire blocking in basement - Fire block top plate on all fur out basement - Horizontal fire block every 10’ basement - Provide Egress window in basement - Add support to fur out around HAVAC longer than 4’ - Fire block penetration in plenum space basement bedroom 3 - Fire block plenum space basement bathroom - Complete ductwork basement bathroom vent - Address joist overlap gaps in basement back third oh house DO NOT INSULATE
All Rough Inspection - Residential Passed 2/28/2022 2/28/2022 02/28/2022
Miscellaneous Correction
Resolved
02/28/2022
Driveway Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
6-7-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Partial 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
Sidewalk has a soft spot on south side near existing sidewalk, will need dug out and compacted. Also has standing water on north side very near property line, will need drained before pouring(both areas marked with paint). All forms are in place and aggregate is compacted outside of those 2 areas. 6/8/22 ES
Driveway Inspection Passed 6/10/2022 6/10/2022 06/14/2022
Misc
Informational
06/07/2022
6-7-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
06/14/2022
Driveway meets LS and ADA spec. 6/13/22 ES
Sidewalk Inspection Passed 06/14/2022
Misc
Corrective Action Required
06/08/2022
Sidewalk has a soft spot on south side near existing sidewalk, will need dug out and compacted. Also has standing water on north side very near property line, will need drained before pouring(both areas marked with paint). All forms are in place and aggregate is compacted outside of those 2 areas. 6/8/22 ES
Misc
Informational
06/14/2022
Sidewalk was poured without a reinspection. Unsure if two questionable spots were corrected prior to placement. 6/13/22 ES
Plot Plan Inspection Passed 6/17/2022 6/17/2022 06/17/2022
Occupancy Inspection - Codes Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
*Install irrigation •Final grading and sod •Gutters and down spouts •Splash blocks •Uncover water meter •Sump discharge minimum of 36” from foundation •Missing nails in joist hangers at deck •Proper fasteners required at ledger to house connection •Uncover smoke detectors •Steps at garage entry have all different rise no code compliant •Label non gfci outlet in unfinished basement
Occupancy Inspection - Codes Residential Failed 06/28/2022
Misc
Corrective Action Required
06/28/2022
*Install irrigation •Final grading and sod •Gutters and down spouts •Splash blocks •Uncover water meter •Sump discharge minimum of 36” from foundation •Missing nails in joist hangers at deck •Proper fasteners required at ledger to house connection •Uncover smoke detectors •Steps at garage entry have all different rise no code compliant •Label non gfci outlet in unfinished basement
Erosion Control Inspection Residential Passed 6/28/2022 06/28/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/28/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 7/7/2022 7/7/2022 07/07/2022
Misc
Resolved
07/07/2022
Documents & Images
Date Uploaded File Type Document Name
04/26/2021 Application Form APPLICATION
04/26/2021 Application Form excise tax
04/27/2021 WV1480 - Air Combustion Calculation 4_27_21
04/27/2021 WV1480 - Permit Application
04/27/2021 WV1480 - Final Engineered Plans 4_26_21
04/28/2021 Approved Plans APPROVED PLANS
04/28/2021 Approved Plans COMBUSTION AIR CALCS.
04/28/2021 WV1480 - Final Plot Plan 4_27_21
04/28/2021 Letter Codes Residential Plan Review
04/29/2021 WV1480 - Final Plot Plan 4_29_21
04/29/2021 Receipt Receipt for transaction:2021-002330
04/29/2021 Letter DS Building Permit
05/06/2021 WV1480 - City Approved Plans 5_5_21
05/06/2021 Approved Plans APPROVED PLANS
05/26/2021 LOT 1480 CITY 5-24-21
05/26/2021 Plot Plan APPROVED PLOT PLAN
05/27/2021 M L Crose 3045 NW Thoreau Dr LSMO Winterset Valley Lot 1480 3rd Party Footing Inspection Report 5-26-21
05/27/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter Codes Residential Plan Review
06/10/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/30/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
07/07/2022 Letter Codes Final Certificate of Occupancy
07/07/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home