Permit Application Status

PRRES20211821


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211821
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASMENT - COVERED DECK
04/15/2021
04/23/2021
10/19/2021
04/27/2022
Locations
Contacts
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
Basement elevation
Corrective Action Required
04/22/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Residential Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
Plot Plan Review Rejected 04/20/2021 04/16/2021
Brandon Kalwei
Basement elevation
Corrective Action Required
04/16/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Residential Plan Review Approved 04/20/2021 04/16/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,274.03 $1,274.03 Paid 04/23/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/23/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/23/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/23/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/23/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/23/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/27/2021 (1:00) 4/27/2021 04/27/2021
Underslab Plumbing Inspection - Residential Passed 5/11/2021 5/11/2021 05/11/2021
Piers/Caissons Inspection - Residential Not Ready 8/4/2021 (2:00) 8/4/2021 08/04/2021
Sewer Service Inspection - R Passed 9/10/2021 09/10/2021
Erosion Control Inspection Residential Failed 9/15/2021 09/15/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/15/2021
EROSION CONTROL REQUIRED ALONG THE SIDE AND ALONG THE STREET. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Passed 9/15/2021 (1:15) 9/15/2021 09/15/2021
Electrical Service Inspection Passed 10/6/2021 10/6/2021 10/06/2021
Gas Service Inspection - Residential Failed 10/6/2021 10/6/2021 10/06/2021
Misc
Corrective Action Required
10/06/2021
-Provide min 10 psi pressure for testing
All Rough Inspection - Residential Failed 10/6/2021 10/6/2021 10/06/2021
Misc
Corrective Action Required
10/06/2021
Misc
Corrective Action Required
10/06/2021
**INSTALL EROSION CONTROL ALONG THE WEST SIDE OF PROPERTY LINE OR ALONG THE DISTURBED SIDE STREET. -Nail garage PFH wall sheathing to sill plates -Over-notched joist above garage -Fb duct/b-vent chase from joist space -Header off cut joist at duct/b-vent chase -Seal penetrations of ceiling return air space -Nail all lvl hanger nail holes above kitchen -Complete fur down of pantry ceiling and Fb as required -Complete electrical to pantry -Shall insulate the return air space above front dining from exterior with min R-13. Do not leave fiberglass insulation exposed inside return air space -Brace lvl roof beam ends from rotation -Studs at front bedroom gable wall not continuous full height -Fb 7/16” gap at top of bedroom 4 bathroom wall -Over-notched rafters at beam bearing -Support stair landings and stringers -Solid block under breakfast I beam point load -Over-notched joist below half bathroom -Fb basement from garage duct/b-vent chase **OK TO INSULATE **PIERS WERE NOT INSPECTED AND APPROVED. PIER INSPECTION WAS SCHEDULED ON 8/4/21 BUT THE PIER HOLES WERE NOT DUG. REMOVE PIERS THAT WERE ALREADY POURED
Gas Service Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/06/2021
-Provide min 10 psi pressure for testing
All Rough Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/06/2021
**INSPECTION DENIED. SEE BELOW **INSTALL EROSION CONTROL ALONG THE WEST SIDE OF PROPERTY LINE OR ALONG THE DISTURBED SIDE STREET. -Nail garage PFH wall sheathing to sill plates -Over-notched joist above garage -Fb duct/b-vent chase from joist space -Header off cut joist at duct/b-vent chase -Seal penetrations of ceiling return air space -Nail all lvl hanger nail holes above kitchen -Complete fur down of pantry ceiling and Fb as required -Complete electrical to pantry -Shall insulate the return air space above front dining from exterior with min R-13. Do not leave fiberglass insulation exposed inside return air space -Brace lvl roof beam ends from rotation -Studs at front bedroom gable wall not continuous full height -Fb 7/16” gap at top of bedroom 4 bathroom wall -Over-notched rafters at beam bearing -Support stair landings and stringers -Solid block under breakfast I beam point load -Over-notched joist below half bathroom -Fb basement from garage duct/b-vent chase **OK TO INSULATE **PIERS WERE NOT INSPECTED AND APPROVED. PIER INSPECTION WAS SCHEDULED ON 8/4/21 BUT THE PIER HOLES WERE NOT DUG. REMOVE PIERS THAT WERE ALREADY POURED
All Rough Inspection - Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/13/2021
-Over-notched joist above garage **remove insulation. Note that the subfloor is only rated for max 24” span -Header off cut joist at duct/b-vent chase **not done -Seal penetrations of ceiling return air space -Complete electrical to pantry -Shall insulate the return air space above front dining from exterior with min R-13. Do not leave fiberglass insulation exposed inside return air space -Fb 7/16” gap at top of bedroom 4 bathroom wall -Over-notched rafters at beam bearing -Support stair landings and stringers -Solid block under breakfast I beam point load -Over-notched joist below half bathroom **have engineer approve the fix -Fb basement from garage duct/b-vent chase **PIERS WERE NOT INSPECTED AND APPROVED. PIER INSPECTION WAS SCHEDULED ON 8/4/21 BUT THE PIER HOLES WERE NOT DUG. REMOVE PIERS THAT WERE ALREADY POURED
Gas Service Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Resolved
10/14/2021
-Provide min 10 psi pressure for testing
All Rough Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
10/14/2021
-Over-notched joist above garage **remove insulation. Note that the subfloor is only rated for max 24” span -Seal penetrations of ceiling return air space -Shall insulate the return air space above front dining from exterior with min R-13. -Redo electrical in front bedroom -Over-notched rafters at beam bearing -Solid block under breakfast I beam point load -Over-notched joist below half bathroom **have engineer approve the fix -Fb basement from garage duct/b-vent chase **PIERS WERE NOT INSPECTED AND APPROVED. PIER INSPECTION WAS SCHEDULED ON 8/4/21 BUT THE PIER HOLES WERE NOT DUG. REMOVE PIERS THAT WERE ALREADY POURED
All Rough Inspection - Residential Failed 10/28/2021 10/28/2021 10/28/2021
Misc
Corrective Action Required
10/27/2021
-Over-notched joist below half bathroom **Just header off the notched joist and redo plumbing **OK TO ROCK
Driveway Inspection Partial 11/15/2021 11/15/2021 11/15/2021
Misc
Informational
11/15/2021
11-15-21 AN forms are in place and aggregate is present and compacted
Piers/Caissons Inspection - Residential Passed 11/19/2021 (8:00) 11/19/2021 11/19/2021
Driveway Inspection Passed 11/19/2021 11/19/2021 11/19/2021
Misc
Informational
11/15/2021
11-15-21 AN forms are in place and aggregate is present and compacted
Misc
Informational
11/19/2021
11-19-21 AN driveway looks good and has expansion joints at curb and right of way and meets ADA specs.
Sidewalk Inspection Partial 11/30/2021 11/30/2021 11/30/2021
Misc
Informational
11/30/2021
11-30-21 AN Forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/30/2021
11-30-21 AN Forms are in place and aggregate is present and compacted
Misc
Informational
12/03/2021
12-3-21 AN sidewalk looks good and meets Ada spec
All Rough Inspection - Residential Passed 02/11/2022
Misc
Resolved
02/11/2022
-Over-notched joist below half bathroom **Just header off the notched joist and redo plumbing **OK TO ROCK
Erosion Control Inspection Residential Passed 2/11/2022 02/11/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/11/2022
EROSION CONTROL REQUIRED ALONG THE SIDE AND ALONG THE STREET. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 2/11/2022 02/11/2022
Misc
Corrective Action Required
02/11/2022
-Address -Final grade, sod, downspout and sump pump extension -Install ladder at window well -Install sewer tracer wire port -Garage door not self-closing -Install backflow preventer at hose bibb -Secure water service pex line
Occupancy Inspection - Codes Residential Temporary C of O 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/11/2022
-Final grade, sod, downspout and sump pump extension
Occupancy Inspection - Codes Residential Full C of O 4/27/2022 4/27/2022 04/27/2022
Misc
Resolved
04/27/2022
-Final grade, sod, downspout and sump pump extension
Documents & Images
Date Uploaded File Type Document Name
04/15/2021 Application Form APPLICATION
04/16/2021 LOT 302 FINAL
04/16/2021 DW Permit Plan Knollbrooke 1904 NE Park Ridge Dr Lot 302 Park Ridge
04/16/2021 Letter Codes Residential Plan Review
04/16/2021 Plot Plan APPROVED PLOT PLAN
04/16/2021 Approved Plans APPROVED PLANS
04/23/2021 Receipt Receipt for transaction:2021-002173
04/23/2021 Letter DS Building Permit
04/27/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/28/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter Codes Temporary Certificate of Occupancy
04/27/2022 Letter Field Certificate of Occupancy
04/27/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents