Permit Application Status

PRRES20211351


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211351
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
03/25/2021
04/08/2021
10/02/2021
06/29/2022
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
ROBERTSON REMODELING LLC, Address:500 James Rollo Dr, Phone:(816) 506-4090  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
LEVIROBERTSON@SBCGLOBAL.NET  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 04/09/2021 12/02/2022
Kim Brennan
Misc
Corrective Action Required
04/07/2021

The applicant is Robertson Remodeling but the builder on the plans says Walker Custom Homes.
Plot Plan Review Approved 04/09/2021 04/07/2021
Kim Brennan
Plot Plan Review Approved 04/06/2021 04/07/2021
Kim Brennan
Deck location
Corrective Action Required
04/05/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Residential Plan Review Rejected 04/06/2021 04/05/2021
Kim Brennan
Misc
Corrective Action Required
04/05/2021

The applicant is Robertson Remodeling but the builder on the plans says Walker Custom Homes.
Planning Review (RES) Approved 04/06/2021 04/02/2021
Hector Soto Jr.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $978.70 $978.70 Paid 04/07/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/07/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/07/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 04/07/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/07/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/07/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/7/2021 (8:30) 5/7/2021 05/07/2021
Erosion Control Inspection Residential Failed 6/2/2021 06/02/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/02/2021
EROSION CONTROL REQUIRED ALONG THE STREET AND STREET CLEANUP SHALL BE COMPLETED IMMEDIATELY NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL AND STREET CLEANUP NOT COMPLETED
Water Service Inspection - R Partial 6/4/2021 06/04/2021
Sewer Service Inspection - R Passed 6/4/2021 06/04/2021
Underslab Plumbing Inspection - Residential Passed 6/4/2021 06/04/2021
Misc
Resolved
06/04/2021
INSPECTION DENIED DUE TO DEFICIENT EROSION CONTROL AND STREET CLEANUP NOT COMPLETED
Water Service Inspection - R Passed 6/8/2021 (10:45) 6/8/2021 06/08/2021
Erosion Control Inspection Residential Failed 6/8/2021 06/08/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/02/2021
EROSION CONTROL REQUIRED ALDONG THE STREET AND STREET CLEANUP SHALL BE COMPLETED IMMEDIATELY NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 10/7/2021 10/7/2021 10/07/2021
Misc
Corrective Action Required
10/07/2021
-Garage PFH wall only: Nail garage PFH wall sheathing to sill plates per code; install tension straps; install 2”x2”x3/16” washers
All Rough Inspection - Residential Failed 11/3/2021 11/3/2021 11/03/2021
Misc
Corrective Action Required
10/07/2021
-Install 2 lag screws at deck beam to post connections -Fb all wall plates penetrations -Seal all penetrations of return air space -Brace ends of roof beam from rotation -Install collar ties per code -Fasten fireplace to framing -Fb the side and back wall of the fireplace space -Provide insulation shield for the fireplace flue -Support rear porch hip rafters at ridge -Reinforce the notched ceiling joist above middle living room window. Don’t header off -Security blocking for deck door -Seal gap at top of the return air space at laundry/living room wall -Support vent piping above pantry/mud/laundry -Protect wiring within six ft of attic access -Window located within 24” of master bedroom deck door must be tempered glass window -Fb stair wall from I beam soffit -Install joist hangers above stair -Fb basement wall vertically at ten ft or less interval; fb wall from bathroom fur down ceiling space; fb front basement bedroom wall from fur down ceiling space -Anchor basement sill plates within 12” of breaks. Min 2 anchors per short plate -Install missing studs at rear color basement -Connect the gas piping bonding conductor to the equipment grounding bus bar -Have engineer address support of the 16” lvl at front fireplace wall **OK TO INSULATE
Electrical Service Inspection Passed 11/3/2021 11/03/2021
Gas Service Inspection - Residential Passed 11/3/2021 11/03/2021
All Rough Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Misc
Corrective Action Required
11/03/2021
**RESTORE EROSION CONTROL ALONG THE REAR OF LOT -Seal holes and gap at top of the return air space at laundry/living room wall -Support hip rafters at ridge above rear porch -Window located within 24” of master bedroom deck door must be tempered glass window **check later -Fb front basement bedroom wall from soffit space ** look at gap where fire can spread from wall into the soffit -Above front unfinished basement area, move the parallel electrical wiring out of return air space and seal all penetrations/hole of return air space **OK TO INSULATE
All Rough Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Misc
Informational
12/27/2021
-Window located within 24” of master bedroom deck door must be tempered glass window **check later **OK TO ROCK
Driveway Inspection Partial 2/10/2022 2/10/2022 02/10/2022
Misc
Informational
02/10/2022
2-10-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Driveway Inspection Partial 2/25/2022 2/25/2022 02/28/2022
Misc
Informational
02/10/2022
2-10-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Misc
Informational
02/28/2022
2-28-22 AN DRIVEWAY LOOKS GOOD AND HAS EXPANSION JOINTS AT CURB AND RIGHT OF WAY
Driveway Inspection Passed 02/28/2022
Misc
Informational
02/28/2022
2-10-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Misc
Informational
02/28/2022
2-28-22 AN DRIVEWAY LOOKS GOOD AND HAS EXPANSION JOINTS AT CURB AND RIGHT OF WAY
Erosion Control Inspection Residential Passed 04/22/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/22/2022
EROSION CONTROL REQUIRED ALDONG THE STREET AND STREET CLEANUP SHALL BE COMPLETED IMMEDIATELY NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
-Raise sewer manhole at front SE corner to grade level -Deck piers not inspected by city -Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide security compliant light at entry such that the bulbs cannot be removed without the use of tool -Provide flashing above window trim at west side of house -Replace deck joist hanger nails with galvanized nails -Install tamper-proof caps at AC valves -Pendant light not allowed within master bathroom tub zone -Cut ufer rebar to safe length
Occupancy Inspection - Codes Residential Temporary C of O 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/22/2022
-Raise sewer manhole at front SE corner to grade level -Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Install tamper-proof caps at AC valves
Occupancy Inspection - Codes Residential Full C of O 6/29/2022 06/29/2022
Misc
Resolved
06/29/2022
-Raise sewer manhole at front SE corner to grade level -Sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Install tamper-proof caps at AC valves
Documents & Images
Date Uploaded File Type Document Name
03/25/2021 Application Form Permit Application and License Tax Form
04/05/2021 Letter Codes Residential Plan Review
04/07/2021 Plot Plan Approved Plot Plan
04/07/2021 Approved Plans Approved Drawings
04/07/2021 Receipt Receipt for transaction:2021-001836
04/08/2021 Letter DS Building Permit
05/07/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
12/06/2021 4072 NE Timberlake Court - Structural Letter (Nov 16, 2021)
12/10/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/25/2022 Final_2021_06_07_DPiers_LSMO_Pat Cochran
04/27/2022 Letter Codes Temporary Certificate of Occupancy
06/29/2022 Letter Codes Final Certificate of Occupancy
06/29/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home