Summary
PRRES20211173
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
03/16/2021
03/24/2021
09/12/2021
12/06/2022
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
SCOTT@NEWMARKHONESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
Residential Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/24/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No carbon monoxide detectors shown
10 Combustion air
Corrective Action Required
03/24/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
03/24/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not specify uninterrupted height
Plot Plan Review Approved 03/18/2021 03/17/2021
Kim Brennan
Property boundary
Corrective Action Required
03/16/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan.
Basement egress
Corrective Action Required
03/16/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Contours, spot elevations and arrows
Corrective Action Required
03/16/2021

Contours, spot elevations and drainage flow arrows (as required) shall be provided on the lot. Please add Contours
Basement opening elevations
Corrective Action Required
03/16/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. No MLOE's are shown on the MDP.
Misc
Corrective Action Required
03/16/2021

I am not getting a 2% slope in the rear. Please explain.
Planning Review (RES) Approved 03/18/2021 03/16/2021
Shannon McGuire
Residential Plan Review Rejected 03/18/2021 03/16/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/16/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No carbon monoxide detectors shown
10 Combustion air
Corrective Action Required
03/16/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
03/16/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not specify uninterrupted height
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,202.81 $1,202.81 Paid 03/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/24/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 03/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/13/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 4/22/2021 04/22/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Failed 4/22/2021 (3:30) 4/22/2021 04/22/2021
Misc
Informational
04/22/2021
UFER SOUTH FOUNDATION WALL AT STEP DOWN FOOTING PASSED FAILED EROSION CONTROL Michael Harkins 04/22/2021 3:44 PM
Footing Inspection - Residential Passed 4/22/2021 at 3:30 PM 04/22/2021
Misc
Informational
04/22/2021
UFER SOUTH FOUNDATION WALL AT STEP DOWN
Erosion Control Inspection Residential Failed 5/20/2021 05/20/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/20/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
Underslab Plumbing Inspection - Residential Passed 6/14/2021 6/14/2021 06/14/2021
Sewer Service Inspection - R Passed 7/2/2021 (1:00) 7/2/2021 07/02/2021
Piers/Caissons Inspection - Residential Passed 7/29/2021 07/29/2021
Misc
Informational
07/29/2021
(2) 24 X 36 PIERS
All Rough Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Miscellaneous Correction
Corrective Action Required
07/29/2021
: PFH GARAGE PORTAL FRAME ONLY : FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" OC PER PLAN OK TO COVER CHECK ABOVE ON ALL ROUGH
Rough Framing Inspection - Residential Failed 10/22/2021 10/22/2021 10/21/2021
Misc
Corrective Action Required
10/21/2021
email contact was undeliverable. \ We no longer inspect portal frame as a seperate inspection. 20211173 302 Nw Ambersham
Gas Service Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Miscellaneous Correction
Corrective Action Required
10/27/2021
PROVIDE BOND GAS LINE (CSST)
Electrical Service Inspection Passed 12/10/2021 12/10/2021 12/10/2021
Gas Service Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Miscellaneous Correction
Corrective Action Required
10/27/2021
GAS PRESSURE AT 7 PSI, MUST MAINTAIN 10 PSI
All Rough Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Miscellaneous Correction
Corrective Action Required
07/29/2021
: PFH GARAGE PORTAL FRAME ONLY : FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" OC PER PLAN OK TO COVER CHECK ABOVE ON ALL ROUGH
Misc
Corrective Action Required
12/10/2021
-anchor bolts required within 12” of plate breaks -Nail all intersecting corners 12” oc -seal all top plate penetrations - see laundry -terminate all bath exhaust fans to exterior -ensure proper slope all DWV vents span across ceiling joists -protection plate bottom plate kitchen pex hall side of wall -fireblock at fireplace open to attic space above through cabinet framing, fireblock between studs at cabinet on hall side -bocca protection plate top plate DWV for master bath vanity on hall side -address top plate connection at exterior walls -unable to inspect covered patio framing with lid cover CS-PF portal design per plans, see detail S4.1 in plans -span plywood across cripple wall less than 14” above front foyer/dining room -collar ties every 48” oc -all purlin and ridge supports per plans -purlin struts not less than 45 degree angle -support DWV every 48” oc, traps not considered support -UFER must remain accessible at finish -set and anchor all SCH 40 steel columns to floor at basement -Secure SE and feeder cables through furred down to code -complete HVAC duct basement den -protection plate DWV top at furred down, basement bathroom den side of wall -secure main water line to foundation wall at basement -complete furred downs basement bedroom and bathroom at beams, SE cable -fireblock vertical to horizontal at furred down soffit end at deadspace basement bedroom closet -nail exterior sheathing per plans
All Rough Inspection - Residential Not Ready 1/4/2022 1/4/2022 01/04/2022
Miscellaneous Correction
Corrective Action Required
12/10/2021
: PFH GARAGE PORTAL FRAME ONLY : FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" OC PER PLAN OK TO COVER CHECK ABOVE ON ALL ROUGH
Misc
Corrective Action Required
12/10/2021
-Nail all intersecting corners 12” oc -seal all top plate penetrations - see laundry & PANTRY -ensure proper slope all DWV vents span across ceiling joists -fireblock at fireplace open to attic space above through cabinet framing, fireblock between studs at cabinet on hall side -bocca protection plate top plate DWV for master bath vanity on hall side -address top plate connection at exterior walls -unable to inspect covered patio framing with lid cover CS-PF portal design per plans, see detail S4.1 in plans -span plywood across cripple wall less than 14” above front foyer/dining room -collar ties every 48” oc -all purlin and ridge supports per plans -purlin struts not less than 45 degree angle -support DWV every 48” oc, traps not considered support -UFER must remain accessible at finish -set and anchor all SCH 40 steel columns to floor at basement ANCHOR BOLT NEAR SERVICE PANEL -Secure SE and feeder cables through furred down to code -complete HVAC duct basement den -protection plate DWV top at furred down, basement bathroom den side of wall -complete furred downs basement bedroom and bathroom at beams, SE cable -fireblock vertical to horizontal at furred down soffit end at deadspace basement bedroom closet -nail exterior sheathing per plans
Gas Service Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Miscellaneous Correction
Resolved
01/11/2022
All Rough Inspection - Residential Failed 1/14/2022 1/14/2022 01/14/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
: PFH GARAGE PORTAL FRAME ONLY : FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" OC PER PLAN OK TO COVER CHECK ABOVE ON ALL ROUGH
Misc
Corrective Action Required
01/04/2022
-Nail all intersecting corners 12” oc -ensure proper slope all DWV vents span across ceiling joists -fireblock at fireplace open to attic space above through cabinet framing, fireblock between studs at cabinet on hall side -address top plate connection at exterior walls -unable to inspect covered patio framing with lid cover -CS-PF portal design per plans, see detail S4.1 in plans -span plywood across cripple wall less than 14” above front foyer/dining room -UFER must remain accessible at finish -nail exterior sheathing per plans
All Rough Inspection - Residential Failed 1/19/2022 01/19/2022
Miscellaneous Correction
Resolved
01/19/2022
: PFH GARAGE PORTAL FRAME ONLY : FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" OC PER PLAN OK TO COVER CHECK ABOVE ON ALL ROUGH
Misc
Corrective Action Required
01/14/2022
-address top plate connection at exterior walls, multiple areas where top plates do not intersect at exterior walls, install a simpson strap to connect different elevation plate lines to meet code. front foyer wall lines, rear wall, breakfast room . -unable to inspect covered patio framing with lid cover , uncovere or provide ladder. -CS-PF portal design per plans, see detail S4.1 in plans , nailing of siding. -span plywood ,across cripple wall less than 14” above front foyer/dining room , not complete. -nail exterior sheathing per plans
All Rough Inspection - Residential Failed 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/19/2022
-address top plate connection at exterior walls, multiple areas where top plates do not intersect at exterior walls, install a simpson strap to connect different elevation plate lines to meet code. front foyer wall lines, rear wall, breakfast room . -unable to inspect covered patio framing with lid cover , uncovere or provide ladder. -CS-PF portal design per plans, see detail S4.1 in plans , nailing of siding. ( 3" GRID PATTERN @ LVL HEADER BREAKFAST NOOK ) -span plywood ,across cripple wall less than 14” above front foyer/dining room , not complete. -nail exterior sheathing per plans ( PER PLAN SHEET S1.0 FASTENING SCHEDULE, REAR & SOUTH SIDES MARKED WITH BLACK MARKER WHERE I COULD REACH )
All Rough Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Misc
Corrective Action Required
01/21/2022
-CS-PF portal design per plans, see detail S4.1 in plans , nailing of siding. ( 3" GRID PATTERN @ LVL HEADER BREAKFAST NOOK )
All Rough Inspection - Residential Passed 2/18/2022 02/18/2022
Misc
Corrective Action Required
01/31/2022
-CS-PF portal design per plans, see detail S4.1 in plans , nailing of siding. ( 3" GRID PATTERN @ LVL HEADER BREAKFAST NOOK )
Sidewalk Inspection Partial 3/3/2022 3/3/2022 03/03/2022
Misc
Informational
03/03/2022
Sidewalk was framed up with aggregate in and compacted. 3/3/22 ES
Driveway Inspection Partial 3/3/2022 3/3/2022 03/03/2022
Misc
Informational
03/03/2022
Driveway was framed up with aggregate in and compacted. 3/3/22 ES
Sidewalk Inspection Passed 3/11/2022 3/11/2022 03/14/2022
Misc
Informational
03/03/2022
Sidewalk was framed up with aggregate in and compacted. 3/3/22 ES
Misc
Informational
03/14/2022
Sidewalk meets LS and Ada spec. 3/14/22 ES
Driveway Inspection Passed 3/11/2022 3/11/2022 03/15/2022
Misc
Informational
03/03/2022
Driveway was framed up with aggregate in and compacted. 3/3/22 ES
Misc
Informational
03/15/2022
Driveway meets LS and Ada specs. 3/15/22 ES
Occupancy Inspection - Codes Residential Failed 5/17/2022 5/17/2022 05/17/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
-WATER SERVICE INSPECTION STILL PENDING -OBTAIN LAWN IRRIGATION PERMIT & SUBMIT -BACK FLOW CERTIFICATION - SUBMIT AS GRADED PLOT PLAN -PROVIDE FINAL GRADE -PROVIDE SOD -PROVIDE SPLASH BLOCKS - COMPLETE STONE FRONT OF HOUSE - PROVIDE PERMANENT ADDRESS - REMOVE DUST COVERS SMOKE DETECTORS - PROVIDE FIXTURE OR COVER PLATE MASTER CLOSET - PROVIDE ANCHOR BOLT SCH 40 COLUMN AT SERVICE PANEL - COMPLETE EXHAUST HOOD KITCHEN -
Plot Plan Inspection Failed 5/17/2022 05/17/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
SUBMIT AS GRADED PLOT PLAN
Plot Plan Inspection Failed 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
SUBMIT AS GRADED PLOT PLAN
Water Service Inspection - R Passed 5/26/2022 05/26/2022
Misc
Informational
05/26/2022
LETTER FROM PLUMBER
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2022 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
-OBTAIN LAWN IRRIGATION PERMIT & SUBMIT -BACK FLOW CERTIFICATION - SUBMIT AS GRADED PLOT PLAN -PROVIDE FINAL GRADE -PROVIDE SOD -PROVIDE SPLASH BLOCKS -
Erosion Control Inspection Residential Passed 12/06/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/20/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/20/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
Plot Plan Inspection Passed 12/7/2022 12/06/2022
Miscellaneous Correction
Resolved
12/06/2022
SUBMIT AS GRADED PLOT PLAN
Occupancy Inspection - Codes Residential Full C of O 12/8/2022 12/8/2022 12/06/2022
Miscellaneous Correction
Resolved
12/06/2022
-OBTAIN LAWN IRRIGATION PERMIT & SUBMIT -BACK FLOW CERTIFICATION - SUBMIT AS GRADED PLOT PLAN -PROVIDE FINAL GRADE -PROVIDE SOD -PROVIDE SPLASH BLOCKS -
Documents & Images
Date Uploaded File Type Document Name
03/16/2021 Application Form Permit Application and License Tax Form
03/16/2021 Letter Codes Residential Plan Review
03/17/2021 Plot Plan Approved Plot Plan
03/24/2021 Approved Plans Approved Drawings
03/24/2021 Receipt Receipt for transaction:2021-001489
03/24/2021 Letter DS Building Permit
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/06/2022 Receipt Receipt for transaction:2022-000107
01/11/2022 Letter INSPECTION SUMMARY
01/13/2022 Receipt Receipt for transaction:2022-000244
01/14/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/25/2022 R&R Plumbing(1)
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter Codes Temporary Certificate of Occupancy
10/13/2022 Letter Codes 140 Day Letter
12/06/2022 Plot Plan Approved As-Graded Plot Plan
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter Codes Final Certificate of Occupancy
12/06/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home