Permit Application Status

PRRES20210742


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210742
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
02/24/2021
07/21/2021
10/02/2021
06/14/2023
Locations
Contacts
Mill Creek Builders Incorporated, Address:21203 W 81st Terrace, Phone:(816) 349-7209  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
TRACY.F@MILLCREEKBUILDERSKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/11/2021 05/07/2021
Kim Brennan
06 Designate use of each room or space
Corrective Action Required
05/07/2021

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Not designated in the finished basement
09 Identify furnace and water heater locations
Corrective Action Required
05/07/2021

Identify furnace and water heater location(s). (IRC Section G2406)
10 Combustion air
Corrective Action Required
05/07/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
05/07/2021

Identify roof covering material (IRC Section R905)
Plot Plan Review Approved 05/11/2021 05/07/2021
Kim Brennan
Plot Plan Review Approved 02/26/2021 04/30/2021
Kim Brennan
Right-of-way
Corrective Action Required
02/24/2021

The right-of-way with dimensions must be provided on the plot plan. Please provide right-of-way along SW Winthrop Dr.
Easements
Corrective Action Required
02/24/2021

All easements with dimensions must be provided on the plot plan.
Spot elevations
Corrective Action Required
02/24/2021

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. Please provide drainage flow arrows throughout the lot
Planning Review (RES) Rejected 03/08/2021 03/08/2021
Jennifer Thompson
ELEVATOR 1
Corrective Action Required
03/08/2021

Label the proposed exterior building materials.
Miscellaneous Correction
Corrective Action Required
03/08/2021

The plat shall be recorded with Jackson County Recorder of Deeds prior to building permit approval.
Residential Plan Review Rejected 02/26/2021 02/24/2021
Kim Brennan
06 Designate use of each room or space
Corrective Action Required
02/24/2021

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Not designated in the finished basement
09 Identify furnace and water heater locations
Corrective Action Required
02/24/2021

Identify furnace and water heater location(s). (IRC Section G2406)
10 Combustion air
Corrective Action Required
02/24/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
02/24/2021

Identify roof covering material (IRC Section R905)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,028.43 $1,028.43 Paid 07/21/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/21/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/21/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 07/21/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 07/21/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/21/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/12/2023
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 8/30/2021 8/30/2021 08/30/2021
Misc
Corrective Action Required
08/30/2021
THIRD PARTY FOOTING REPORT REJECTED AS IT IS INCOMPLETE. FOOTING INSPECTION NOT COMPLETED DUE TO LACK OF EROSION CONTROL ON LOT AT TIME OF INSPECTION AS REQUIRED
Erosion Control Inspection Residential Failed 8/30/2021 8/30/2021 08/30/2021
DCM5 ESC INSP DENIED
Corrective Action Required
08/30/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE
Underslab Plumbing Inspection - Residential Passed 9/20/2021 9/20/2021 09/20/2021
Suspended Slab Inspection Passed 10/13/2021 10/12/2021 10/12/2021
Electrical Service Inspection Failed 5/25/2022 5/25/2022 05/25/2022
Miscellaneous Correction
Corrective Action Required
05/25/2022
-IDENTIFY UFER GROUND AT EACH END -PROVIDE PROPER LISTED CLAMP AT UFER CONNECTION -REMOVE BONDING JUMPER IN SUB PANEL- ISOLATE GROUND AND NEUTRAL BARS
Gas Service Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/25/2022
-COMPLETE GAS CONNECTION TO FIREPLACE -IDENTIFY METALLIC GAS LINE BONDING CONDUCTOR AT EACH END
All Rough Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/25/2022
-Post address before any further inspections -Unable to verify nailing pattern at braced walls and PFH -Tighten anchor bolts throughout -Anchor bolts to be in middle third of plate at PFH -Provide (2) rows 16d sinkers 3" oc at plate to header at PFH-see detail -Provide anchor bolt at single car bay back wall end of plate -Nail all corner and intersecting wall studs 12” oc -Tie exterior walls together at pantry -Nail sheathing at pantry, bedrooms, etc -Provide collar ties at covered porch/dining room rafters -Provide lateral bracing at each side of upset beams great room -Complete fireplace gas connection -Security blocking at back door -Have engineer address holes bored closer together than 2” and closer than 2” to bottom of joists in basement family room and unfinished space -Fireblock ceiling line at stair landings -Joist hangers at stair landing joists over 48” -Pan off return air in soffit space at hallway -Fireblock bedroom closet behind furout at ceiling and 10’ vertical -Tighten anchor bolts in basement -Provide full bearing at joist in SW Corner -Exterior not inspected at this time-Complete deck framing and exterior nailing **OK TO INSULATE AS DISCUSSED- DO NOT COVER ANY INSPECTION ITEMS
Water Service Inspection - R Passed 7/15/2022 (1:00) 7/15/2022 07/15/2022
Sewer Service Inspection - R Partial 7/15/2022 (1:00) 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/15/2022
Partial sewer from house to back of property
All Rough Inspection - Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
05/25/2022
-Provide (2) rows 16d sinkers 3" oc at plate to header at PFH-see detail -Exterior not inspected at this time-Complete deck framing and exterior nailing **OK TO INSULATE AS DISCUSSED- DO NOT COVER ANY INSPECTION ITEMS
Electrical Service Inspection Passed 7/26/2022 7/26/2022 07/26/2022
Miscellaneous Correction
Resolved
07/26/2022
Gas Service Inspection - Residential Passed 7/26/2022 7/26/2022 07/26/2022
Misc
Resolved
07/26/2022
All Rough Inspection - Residential Passed 7/26/2022 7/26/2022 07/26/2022
Misc
Resolved
07/26/2022
Sewer Service Inspection - R Passed 8/2/2022 (11:15) 8/2/2022 08/02/2022
Misc
Resolved
08/02/2022
Partial sewer from house to back of property
Driveway Inspection Passed 9/7/2022 9/7/2022 09/07/2022
Misc
Informational
09/07/2022
On Wednesday, 9-07-2022, I performed and passed a driveway for concrete placement.
Miscellaneous Inspection Passed 2/6/2023 2/6/2023 02/06/2023
Misc
Informational
02/06/2023
PERMIT HOLDER HAS REQUESTED AN EXTENSION TO COMPLETE TO PROJECT. WILL BE READY FOR FINAL IWITHIN 2 WEEKS
Footing Inspection - Residential Passed 04/25/2023
Misc
Resolved
04/25/2023
THIRD PARTY FOOTING REPORT REJECTED AS IT IS INCOMPLETE. FOOTING INSPECTION NOT COMPLETED DUE TO LACK OF EROSION CONTROL ON LOT AT TIME OF INSPECTION AS REQUIRED
Piers/Caissons Inspection - Residential Passed 04/25/2023
Occupancy Inspection - Codes Residential Failed 4/25/2023 4/25/2023 04/25/2023
Misc
Corrective Action Required
04/25/2023
-GFCI at front porch loose, doesn't trip -Label GFCI in garage -GFCI under sink not working -Secondary lock on sliding doors -self closing hinges at garage door -lockout needed on water heater breaker -label non GFCI sump pump -Spark ring missing at Fireplace outlet -Spark ring missing at kitchen outlets -Ensure all Arc fault required in breaker panel E3902.16 of the 2018 IRC -Label non GFCI's in basement -secure whip to water heater -sump pump discharge 36 inches from foundation -splash blocks to dischargey 36inches from foundation -secure whip at AC within 12 inches of disconnect box -obtained issued lawn irrigation permit
Erosion Control Inspection Residential Passed 5/11/2023 05/11/2023
DCM5 ESC INSP DENIED
Resolved
05/11/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE
Plot Plan Inspection Passed 5/11/2023 05/11/2023
Occupancy Inspection - Codes Residential Failed 5/11/2023 5/11/2023 05/11/2023
Misc
Corrective Action Required
04/25/2023
-Ensure all Arc fault required in breaker panel -secure whip to water heater -obtain a lawn irrigation permit - address deck post to beam connection - provide 6" clearance siding to grade
Occupancy Inspection - Codes Residential Ready for Temp CO 5/12/2023 5/12/2023 05/12/2023
Misc
Corrective Action Required
05/11/2023
-obtain a lawn irrigation permit - provide 6" clearance siding to grade
Occupancy Inspection - Codes Residential Ready for Temp CO 6/9/2023 06/09/2023
Misc
Corrective Action Required
05/12/2023
-obtain a lawn irrigation permit - provide 6" clearance siding to grade
Occupancy Inspection - Codes Residential Full C of O 6/14/2023 06/14/2023
Misc
Resolved
06/14/2023
Documents & Images
Date Uploaded File Type Document Name
02/24/2021 Application Form Permit Application
02/24/2021 Application Form License Tax Form
04/05/2021 Letter Codes Residential Plan Review
04/30/2021 Plot Plan Approved Plot Plan
05/07/2021 Approved Plans Approved Drawings
05/07/2021 Email Email 1518 SW Heartwood Drive
07/21/2021 Permit DS Building Permit
07/21/2021 Receipt Receipt for transaction: 2021-005843
07/21/2021 Permit DS Building Permit
08/30/2021 M L Crose 1518 SW Heartwood Dr LSMO Woodland Glen Lot 1 Mill Creek Bldrs Permit 2021-0742 3rd Party Footing Inspection Report 8-27-21
08/30/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/09/2022 Mill Creek Builders 1514 1518 SW Heartwood Dr LSMO Deck Support Post Pier Inspection Report 9-6-22 (002)
09/20/2022 Mill Creek Builders 1518 SW Heartwood Dr LSMO Deck Support Post Pier Inspection Report 9-6-22
01/25/2023 Letter Codes 140 Day Letter
02/06/2023 Letter INSPECTION SUMMARY
04/25/2023 Letter INSPECTION SUMMARY
04/25/2023 Letter INSPECTION SUMMARY
04/25/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/12/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/12/2023 Receipt Receipt for transaction:2023-003190
06/09/2023 Letter TCO EXTENSION
06/14/2023 Letter Field Certificate of Occupancy
06/14/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home