Permit Application Status

PRRES20210628


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210628
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO TILE ROOF SIDE YARD SWALE TO DRAIN TO THE STREET
02/16/2021
02/18/2021
08/16/2021
06/17/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MIKE@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/22/2021 02/18/2021
Kim Brennan
Residential Plan Review Approved 02/22/2021 02/18/2021
Kim Brennan
Plot Plan Review Rejected 02/19/2021 02/17/2021
Kim Brennan
Planning Review (RES) Approved 02/19/2021 02/17/2021
Shannon McGuire
Residential Plan Review Approved 02/19/2021 02/17/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $901.33 $901.33 Paid 02/18/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/18/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/18/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/18/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/18/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/26/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/12/2021 (1:00) 4/12/2021 04/12/2021
Misc
Corrective Action Required
04/12/2021
Not per city approved plans
Footing Inspection - Residential Passed 4/23/2021 04/23/2021
Misc
Resolved
04/23/2021
Not per city approved plans
Misc
Informational
04/23/2021
3RD PARTY FOOTING BY COLBY SHAW @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATION REAR GARAGE WALL NW CORNER
Underslab Plumbing Inspection - Residential Passed 4/29/2021 4/29/2021 04/29/2021
Sewer Service Inspection - R Passed 9/13/2021 (10:30) 9/13/2021 09/13/2021
Water Service Inspection - R Passed 9/14/2021 (1:30) 9/14/2021 09/14/2021
Gas Service Inspection - Residential Passed 9/21/2021 9/21/2021 09/21/2021
Erosion Control Inspection Residential Failed 09/21/2021
Misc
Corrective Action Required
09/21/2021
*9-21-21 -MAINTAINT GRAVEL FILTER, CLEAN DEBRIS FROM STORM INLET, RESTORE SILT FENCE AT PERIMETER BEFORE ANY FURTHER INSPECTIONS
All Rough Inspection - Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/14/2021
-City approved, stamped plans required on site for inspection
Electrical Service Inspection Failed 10/14/2021 10/14/2021 10/14/2021
All Rough Inspection - Residential Not Ready 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/14/2021
-City approved, stamped plans required on site for inspection, 2nd inspecction no truss plans. no rear door , missing 3 windows, no gravel entrance. Fire rated walls are not correct. soffits not blocked. this is the 8th house with the same issue.
Erosion Control Inspection Residential Failed 10/22/2021 10/22/2021
Misc
Corrective Action Required
09/21/2021
*9-21-21 -MAINTAINT GRAVEL FILTER, CLEAN DEBRIS FROM STORM INLET, RESTORE SILT FENCE AT PERIMETER BEFORE ANY FURTHER INSPECTIONS
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Electrical Service Inspection Passed 10/27/2021 10/27/2021 10/27/2021
All Rough Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
10/22/2021
-City approved, stamped plans required on site for inspection, 2nd inspecction no truss plans. no rear door , missing 3 windows, no gravel entrance. Fire rated walls are not correct. soffits not blocked. this is the 8th house with the same issue.
Miscellaneous Correction
Corrective Action Required
10/27/2021
Seal floor penetrations at fireplace Seal fire blocking at fireplace Nail studs at intersecting wall corners per plan Seal upward penetration bed 2 & dead space Nail LIBs throughout Provide midpoint support vertical 2" & smaller DWV throughout Provide 4 studs at GT bearing points per roof plan Install missing windows & SGD Nail CS-PF exterior bracing per plan at SGD Secure wall at basement stairs Provide anchor bolt single car garage Tighten anchor bolts garage Seal upward penetrations garage Seal fire blocking at soffits
All Rough Inspection - Residential Not Ready 11/3/2021 11/3/2021 11/03/2021
Misc
Corrective Action Required
10/27/2021
-City approved, stamped plans required on site for inspection, 2nd inspecction no truss plans. no rear door , missing 3 windows, no gravel entrance. Fire rated walls are not correct. soffits not blocked. this is the 8th house with the same issue.
Miscellaneous Correction
Corrective Action Required
10/27/2021
Seal fire blocking at fireplace ( against master bedroom ) Nail LIBs throughout ( 2 nails top & bottom and every stud throughout ) Provide 4 studs at GT bearing points per roof plan ( MASTER BEDROOM) Install missing windows Nail CS-PF exterior bracing per plan at SGD ( 2018 IRC FIGURE R602.10.6.4 METHOD CS-PF over raised wood floor - overlap option )
All Rough Inspection - Residential Passed 11/10/2021 11/10/2021 11/10/2021
Misc
Resolved
11/10/2021
Miscellaneous Correction
Corrective Action Required
11/03/2021
Install missing windows
Driveway Inspection Partial 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/12/2021
Driveway is framed up with aggregate in place and compacted. Needs one section of curb replaced in front of drive. 11/12 ES
Plot Plan Inspection Failed 3/2/2022 03/02/2022
Miscellaneous Correction
Corrective Action Required
03/02/2022
PROVIDE FINAL GRADE REMOVE TRASH & CONSTRUCTION DEBRIS COMPLETE RETAINING WALL BACK YARD
Erosion Control Inspection Residential Failed 3/2/2022 03/02/2022
Misc
Corrective Action Required
10/22/2021
*9-21-21 -MAINTAINT GRAVEL FILTER, CLEAN DEBRIS FROM STORM INLET, RESTORE SILT FENCE AT PERIMETER BEFORE ANY FURTHER INSPECTIONS
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/02/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN GUTTER BUDDY ( REMOVE TRASH & SEDIMENT BUILD UP )
Occupancy Inspection - Codes Residential Failed 3/2/2022 3/2/2022 03/02/2022
Miscellaneous Correction
Corrective Action Required
03/02/2022
NO Rated assembly inspection on record ( verify 5/8 type x & screw pattern ) Obtain lawn irrigation permit & submit back flow certification Driveway inspection pending Complete retaining wall back yard Provide final grade, sod, splash blocks Remove trash from window well expose drain Sump shall discharge 36" from foundation Seal top of exterior light fixtures Provide lock out device at service panel for oven & microwave
Occupancy Inspection - Codes Residential Temporary C of O 3/11/2022 3/11/2022 03/11/2022
Miscellaneous Correction
Corrective Action Required
03/02/2022
TCO UNTIL 4/13/22 Obtain lawn irrigation permit & submit back flow certification Driveway inspection pending Complete retaining wall back yard Provide final grade, sod, splash blocks Sump shall discharge 36" from foundation Seal top of exterior light fixtures Did not check exterior items to much snow 3/11/22 Mitch Schwarz
Driveway Inspection Failed 3/15/2022 3/15/2022 03/15/2022
Misc
Informational
11/12/2021
Driveway is framed up with aggregate in place and compacted. Needs one section of curb replaced in front of drive. 11/12 ES
Misc
Corrective Action Required
03/15/2022
Busted section of curbing still needs to be replaced. RP 3-15-22
Erosion Control Inspection Residential Passed 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/26/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/26/2022
Plot Plan Inspection Passed 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
03/02/2022
PROVIDE FINAL GRADE REMOVE TRASH & CONSTRUCTION DEBRIS COMPLETE RETAINING WALL BACK YARD
Occupancy Inspection - Codes Residential Failed 5/26/2022 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
TCO UNTIL 4/13/22 Driveway inspection pending Complete retaining wall back yard
Driveway Inspection Failed 05/26/2022
Misc
Informational
03/15/2022
Driveway is framed up with aggregate in place and compacted. Needs one section of curb replaced in front of drive. 11/12 ES
Misc
Corrective Action Required
03/15/2022
Busted section of curbing still needs to be replaced. RP 3-15-22
Misc
Corrective Action Required
05/26/2022
Busted curbing has still not been replaced. 5/26/22 ES
Driveway Inspection Failed 06/06/2022
Misc
Informational
05/26/2022
Driveway is framed up with aggregate in place and compacted. Needs one section of curb replaced in front of drive. 11/12 ES
Misc
Corrective Action Required
05/26/2022
Busted section of curbing still needs to be replaced. RP 3-15-22
Misc
Corrective Action Required
05/26/2022
Busted curbing has still not been replaced. 5/26/22 ES Busted curb still hasn’t been replaced. 6/6/22 ES
Occupancy Inspection - Codes Residential Failed 6/13/2022 6/13/2022 06/13/2022
Miscellaneous Correction
Corrective Action Required
05/26/2022
TCO UNTIL 4/13/22 Driveway inspection pending Needs one section of curb replaced in front of drive. 11/12 ES
Driveway Inspection Passed 6/13/2022 6/13/2022 06/17/2022
Misc
Resolved
06/17/2022
Driveway is framed up with aggregate in place and compacted. Needs one section of curb replaced in front of drive. 11/12 ES
Misc
Resolved
06/17/2022
Busted section of curbing still needs to be replaced. RP 3-15-22
Misc
Resolved
06/17/2022
Busted curbing has still not been replaced. 5/26/22 ES Busted curb still hasn’t been replaced. 6/6/22 ES
Occupancy Inspection - Codes Residential Full C of O 6/15/2022 6/20/2022 06/17/2022
Miscellaneous Correction
Resolved
06/17/2022
TCO UNTIL 4/13/22 Driveway inspection pending Needs one section of curb replaced in front of drive. 11/12 ES
Documents & Images
Date Uploaded File Type Document Name
02/16/2021 Application Form Permit Application and License Tax Form
02/16/2021 2630107 RF SEALS 02042021
02/17/2021 Approved Plans Approved Drawings
02/17/2021 Approved Plans Approved Truss Layout
02/17/2021 Approved Plans Approved Truss Package
02/17/2021 Letter Codes Residential Plan Review
02/18/2021 Plot Plan Approved Plot Plan
02/18/2021 Receipt Receipt for transaction:2021-000784
02/18/2021 Letter DS Building Permit
03/01/2021 Scope of Work Statement - W1 #41
03/01/2021 W1 #41 - Revised Torino - Mediterranean - Sheets- signed
03/01/2021 Approved Plans APPROVED PLANS
04/12/2021 Letter INSPECTION SUMMARY
04/23/2021 W1-41 Woodside Ridge Footing Inspection
04/23/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter Codes Temporary Certificate of Occupancy
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
05/25/2022 Plot Plan Approved As Graded Plot Plan
05/26/2022 Receipt Receipt for transaction:2022-003975
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter Codes Final Certificate of Occupancy
06/17/2022 Letter Field Certificate of Occupancy
06/17/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home