Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/01/2021 01/28/2021
Brandon Kalwei
Residential Plan Review Approved 02/01/2021 01/28/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $985.32 $985.32 Paid 02/05/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 02/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/05/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/05/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/05/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/5/2021 (10:45) 2/5/2021 02/05/2021
Sewer Service Inspection - R Passed 3/30/2021 03/30/2021
Water Service Inspection - R Passed 3/31/2021 (10:00) 3/31/2021 03/31/2021
Underslab Plumbing Inspection - Residential Failed 4/14/2021 4/14/2021 04/14/2021
Misc
Corrective Action Required
04/14/2021
Protect water service pipe at concrete floor penetration
Erosion Control Inspection Residential Failed 4/14/2021 04/14/2021
Misc
Corrective Action Required
04/14/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Underslab Plumbing Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
Misc
Resolved
04/15/2021
Protect water service pipe at concrete floor penetration
Erosion Control Inspection Residential Failed 4/14/2021 05/18/2021
Misc
Corrective Action Required
04/14/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Gas Service Inspection - Residential Passed 7/29/2021 07/29/2021
Electrical Service Inspection Passed 7/29/2021 07/29/2021
All Rough Inspection - Residential Failed 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
-Provide anchor bolt at end plate north garage wall -Tighten all anchor bolts -Fireblock beam webs in finished walls -Seal penetration at garage entry top plate -Strap garage wall /entry wall where plates do not overlap -Seal gap in flue pan fire blocking -Strap top plates at exterior corner of dining and great room -Address LVL short of load bearing garage/pantry wall-currently bearing on non load bearing wall and load not transferred to foundation and not 1 1/2” of bearing either ply -Fireblock ceiling line at dryer vent -Midpoint strap DWV bed 2 closet and basement -Anchor steel columns -Address joist bored in middle third and 2 holes bored within 2” at furnace -Seal penetrations in floor and joist at return air space outside of game area -Seal plate penetration hall between bed 3 and 4 -Fireblock soffit line at columns -Bocca plates at top plates dwv in basement bath both sides -Nail all exterior sheathing 6" OC perimeter and 12" OC in field
All Rough Inspection - Residential Failed 8/3/2021 8/3/2021 08/03/2021
Misc
Corrective Action Required
07/29/2021
-Tighten all anchor bolts-north by door opening -Seal gap in flue pan fire blocking-Back left corner -Address LVL short of load bearing garage/pantry wall-currently bearing on non load bearing wall and load not transferred to foundation -THE PANTRY WALL IS NOT A LOAD BEARING WALL AND THE LOAD IS NOT BEING TRANSFERRED TO THE FOUNDATION -Fireblock ceiling line at dryer vent-AT GAPS IN FIREBLOCKING -Midpoint strap DWV 2” and smaller in basement -Address joist bored in middle third and 2 holes bored within 2” at furnace-have engineer approve field correction -Seal penetrations in floor and joist at return air space outside of game area
All Rough Inspection - Residential Passed 8/4/2021 08/04/2021
Misc
Resolved
08/04/2021
-Tighten all anchor bolts-north by door opening -Seal gap in flue pan fire blocking-Back left corner -Address LVL short of load bearing garage/pantry wall-currently bearing on non load bearing wall and load not transferred to foundation -THE PANTRY WALL IS NOT A LOAD BEARING WALL AND THE LOAD IS NOT BEING TRANSFERRED TO THE FOUNDATION -Fireblock ceiling line at dryer vent-AT GAPS IN FIREBLOCKING -Midpoint strap DWV 2” and smaller in basement -Address joist bored in middle third and 2 holes bored within 2” at furnace-have engineer approve field correction -Seal penetrations in floor and joist at return air space outside of game area
Driveway Inspection Passed 10/5/2021 10/5/2021 10/05/2021
Misc
Informational
10/05/2021
On Tuesday, 10-05-2021. I performed a driveway inspection and passed the sub grade for placement of concrete.
Sidewalk Inspection Passed 10/5/2021 10/5/2021 10/05/2021
Misc
Informational
10/05/2021
On Tuesday, 10-05-2021. I performed a sidewalk inspection and passed sub grade for placement of concrete.
Plot Plan Inspection Passed 3/9/2022 03/09/2022
Occupancy Inspection - Codes Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-erosion control at front of lot need be in compliance before any further inspections -sod -address piers poured without inspection -check water meter at time of sod and other exterior items -address siding and roofing not completed at front of home -splash blocks and sump pump discharge to extend 36” from foundation -guard rail where required at front stoop where over 30” 36” out -window above master tub need be tempered -window at master back wall near patio door need be tempered -security screws at back patio doors -flood light at rear of home
Occupancy Inspection - Codes Residential Temporary C of O 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/09/2022
-erosion control at front of lot need be in compliance before any further inspections -sod -address piers poured without inspection -check water meter at time of sod and other exterior items -address siding and roofing not completed at front of home -splash blocks and sump pump discharge to extend 36” from foundation -guard rail where required at front stoop where over 30” 36” out -window above master tub need be tempered -window at master back wall near patio door need be tempered -flood light at rear of home
Occupancy Inspection - Codes Residential Failed 7/29/2022 07/29/2022
Misc
Corrective Action Required
03/10/2022
-window at master back wall near patio door need be tempered
Occupancy Inspection - Codes Residential Full C of O 08/02/2022
Misc
Resolved
08/02/2022
-window at master back wall near patio door need be tempered
Piers/Caissons Inspection - Residential Not Ready 01/31/2023
Documents & Images
Date Uploaded File Type Document Name
01/28/2021 Application Form APPLICATION
01/28/2021 LOT 20 FINAL survey
01/28/2021 WWS020 Spec - Sealed Plans (January 25, 2021)
01/28/2021 Approved Plans APPROVED PLANS
01/28/2021 Plot Plan APPROVED PLOT PLAN
02/05/2021 Receipt Receipt for transaction:2021-000575
02/05/2021 Letter DS Building Permit
02/05/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/15/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
02/22/2022 Letter Codes 140 Day Letter
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Slab Inspection 1721 River Run
03/10/2022 Letter Codes Temporary Certificate of Occupancy
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home