PRRES20204954
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - ROOF TRUSS PACKAGE
12/29/2020
01/14/2021
07/03/2021
02/21/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/19/2021 01/14/2021
Dylan Eppert
Legal description
Corrective Action Required
01/14/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. 345 NW AMBERSHAM DR. IS THE CORRECT ADDRESS FOR THIS LOT.
Property boundary
Corrective Action Required
01/14/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. EAST PROPERTY BEARING AND DISTANCE DOESN'T MATCHE THE PLAT. NORTH PROPERTY DOESN'T MATCH PLAT. PLOT PLAN SHOWS R=311' AND L=101.02' WHILE PLAT SAYS R=200' AND L=89.47 PLEASE VERIFY.
Sidewalks
Corrective Action Required
01/14/2021

Sidewalks with dimensions must be provided on the plot plan. THE PLAT DOESN'T SHOW A SIDEWALK ON THE NW AMBERSHAM DR. SIDE. PLEASE VERIFY.
Lot elevations
Corrective Action Required
01/14/2021

Existing and finish elevations at all property corners must be provided on the plot plan. MISSING PROPERTY CORNER ELEVATIONS AT THE NORTHWEST CORNERS OF THE LOT.
Residential Plan Review Approved 01/19/2021 01/14/2021
Dylan Eppert
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/14/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) NOT LABELED IN BEDROOM #2.
Plot Plan Review Rejected 12/31/2020 01/04/2021
Dylan Eppert
Legal description
Corrective Action Required
01/04/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. 345 NW AMBERSHAM DR. IS THE CORRECT ADDRESS FOR THIS LOT.
Property boundary
Corrective Action Required
01/04/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. EAST PROPERTY BEARING AND DISTANCE DOESN'T MATCHE THE PLAT. NORTH PROPERTY DOESN'T MATCH PLAT. PLOT PLAN SHOWS R=311' AND L=101.02' WHILE PLAT SAYS R=200' AND L=89.47 PLEASE VERIFY.
Sidewalks
Corrective Action Required
01/04/2021

Sidewalks with dimensions must be provided on the plot plan. THE PLAT DOESN'T SHOW A SIDEWALK ON THE NW AMBERSHAM DR. SIDE. PLEASE VERIFY.
Lot elevations
Corrective Action Required
01/04/2021

Existing and finish elevations at all property corners must be provided on the plot plan. MISSING PROPERTY CORNER ELEVATIONS AT THE NORTHWEST CORNERS OF THE LOT.
Residential Plan Review Rejected 12/31/2020 01/04/2021
Dylan Eppert
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/04/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) NOT LABELED IN BEDROOM #2.
Planning Review (RES) Approved 01/04/2021 12/30/2020
Shannon McGuire
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,559.14 $1,559.14 Paid 01/14/2021
8331507-Sewer Connection Fee $660.00 $660.00 Paid 01/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/14/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/21/2024
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/21/2024
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/21/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 3/8/2021 (11:30) 3/8/2021 03/08/2021
Water Service Inspection - R Passed 3/9/2021 (9:00) 3/9/2021 03/09/2021
Misc
Corrective Action Required
03/09/2021
- PROVIDE ADDRESS -
Underslab Plumbing Inspection - Residential Passed 3/23/2021 3/23/2021 03/23/2021
Footing Inspection - Residential Passed 3/23/2021 03/23/2021
Misc
Informational
03/23/2021
- 3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER LOCATED RIGHT REAR CORNEROF GARAGE FOUNDATION WALL -
Piers/Caissons Inspection - Residential Passed 4/23/2021 (1:00) 4/23/2021 04/23/2021
Misc
Informational
04/23/2021
(2) 24 x 36 w/ (4) # 4 vert bars per plan
Gas Service Inspection - Residential Passed 6/11/2021 6/11/2021 06/11/2021
Electrical Service Inspection Passed 6/11/2021 06/11/2021
All Rough Inspection - Residential Failed 6/11/2021 6/11/2021 06/11/2021
Misc
Corrective Action Required
06/11/2021
Install back ordered windows Tyvek tape nail penetrations garage Fire block furr outs sales office Tighten anchor bolts sales office Support soffit in sales office to joist above Secure SCH 40 column foyer at stairway Seal fire blocking chases in great room Support VERTICAL 2" &'smaller DWV Vent bath exhaust to daylight Nail corners at braced wall panels Nails triple LVL joist hanger main floor bath Seal HVAC CHASE behind refrigerator Provide 3" SCH 40 column garage per plan Provide joist hanger basement between LVLs & stairway Provide anchor bolts SCH 40 column near furnace Seal vertical to horizontal fire blocking north wall gym & closet Provide vertical fire block & seal at foundation wall every 10' gym closet Fire block (insulate) beam pockets Seal upward penetration sump discharge near service panel & bore left of service panel Fire block ( insulate ) soffit above service panel Provide 4 stud pack at GT bearing points per roof plan Fire block insulate tub trap jack n Jill bath Seal dead space master bed door Seal dead space master water closet Seal top plate master shower seat Seal dead space master closet Seal top plate bath #2 DWV Seal dead space at door to bed # 2
All Rough Inspection - Residential Not Ready 6/25/2021 6/25/2021 06/25/2021
Misc
Corrective Action Required
06/11/2021
Seal fire blocking chases in great room Seal DWV top plate penetrations outside gym/bath # 4 & rec room Fire block (insulate) beam pockets Fire block ( insulate ) soffit above service panel Provide 4 stud pack at GT bearing points per roof plan ( MASTER CLOSET) Seal dead space master bed door
All Rough Inspection - Residential Passed 6/28/2021 6/28/2021 06/28/2021
Misc
Resolved
06/28/2021
Driveway Inspection Not Ready 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/08/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Driveway Inspection Partial 7/9/2021 7/9/2021 07/09/2021
Misc
Corrective Action Required
07/08/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Misc
Informational
07/09/2021
Forms were placed and aggregate was present and compacted. RP 7-9-21
Driveway Inspection Passed 7/16/2021 7/16/2021 07/16/2021
Misc
Corrective Action Required
07/09/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Misc
Informational
07/09/2021
Forms were placed and aggregate was present and compacted. RP 7-9-21
Misc
Informational
07/16/2021
Finished driveway meets LS and ADA specs. RP 7-16-21
Sidewalk Inspection Partial 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
09/10/2021
Forms were placed and aggregate was present and compacted. Plot plan shows sidewalk on both streets, but the sidewalk on Ambersham is on the other side of the roadway. I will check this out and get back to the contractor. RP 9-10-21
Sidewalk Inspection Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Informational
09/10/2021
Forms were placed and aggregate was present and compacted. Plot plan shows sidewalk on both streets, but the sidewalk on Ambersham is on the other side of the roadway. I will check this out and get back to the contractor. RP 9-10-21
Misc
Informational
09/17/2021
Finished driveway meets LS and ADA specs. Check with planning about the sidewalk on Ambersham. Plat is recorded as “no sidewalk” on that side of the roadway. RP 9-17-21
Occupancy Inspection - Codes Residential Not Ready 9/27/2021 9/27/2021 09/27/2021
Miscellaneous Correction
Corrective Action Required
09/27/2021
pay outstanding fees Convert sales office to garage for C of O Posted address not same as permit Provide sidewalk per plot plan Submit back flow certification lawn irrigation Provide light fixture & seal fixtures front of garage Label non GFCI receptacles sales office Provide self closing & latching door at mud room Land conductors in a box or listed fixture left of kitchen sink Provide cover plate GFCI countertop pantry side Provide SGD lock & secondary lock Complete non combustible finish at fireplace Complete stairway Provide lock out device for range at service panel Provide back flow device a water shutoff near furnace Install water heater Provide cover plate at wet bar Provide GFCI protection basement bath vanity Provide fixture or cover plate open j box exercise room basement Complete tub master Sump shall discharge 36" from foundation Secure downspout south rear corner Seal top of meter can,ac disconnect Seal exterior penetrations at service panel & irrigation at garage Mini split max breaker 20 amp has 30 amp Raise manhole cover to grade
Occupancy Inspection - Codes Residential Temporary C of O 10/12/2021 10/12/2021 10/12/2021
Miscellaneous Correction
Corrective Action Required
09/27/2021
Convert sales office to garage for C of O Repair sod and grade at front water meter. , recall when office is changed back to a garage for COFO.
Plot Plan Inspection Passed 02/21/2024
Occupancy Inspection - Codes Residential Full C of O 2/21/2024 2/21/2024 02/21/2024
Miscellaneous Correction
Resolved
02/21/2024
Convert sales office to garage for C of O Repair sod and grade at front water meter. , recall when office is changed back to a garage for COFO.
Documents & Images
Date Uploaded File Type Document Name
12/29/2020 Application Form W0 #73 - Permit App
12/29/2020 73 WOODSIDE RIDGE 1ST FLOOR LAYOUT
12/29/2020 73 WOODSIDE RIDGE 2ND FLOOR LAYOUT
12/29/2020 LOT 73 FINAL
12/29/2020 W0 #73 - Winchester - Modern Farm House - Sheets- signed
12/30/2020 LOT 73 FINAL
12/30/2020 Drawing APPROVED 1ST FLOOR TRUSS LAYOUT
12/30/2020 Drawing APPROVED 2ND FLOOR TRUSS LAYOUT
12/30/2020 Specifications APPROVED TRUSS PACKAGE
01/04/2021 Letter Codes Residential Plan Review
01/06/2021 Email CITY APPROVAL OF SIDEWALKS FOR LOT 73,74 AND 75
01/14/2021 Plans APPROVED HOUSE PLAN
01/14/2021 Receipt Receipt for transaction:2021-000236
01/14/2021 Letter DS Building Permit
03/08/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/23/2021 Lot 73 Woodside Ridge Footing Inspection
03/23/2021 Letter INSPECTION SUMMARY
04/23/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/28/2021 Plot Plan APPROVED PLOT PLAN
10/12/2021 Letter Codes Temporary Certificate of Occupancy
02/21/2024 Receipt Receipt for transaction:2024-000981
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter Field Certificate of Occupancy
02/21/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home