Permit Application Status

PRRES20204780


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204780
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - COVERED DECK - UNFINISHED BASEMENT - CLAY TILE ROOF
12/15/2020
12/22/2020
06/19/2021
11/10/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/28/2020 12/22/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
12/22/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 12/28/2020 12/22/2020
Dylan Eppert
Plot Plan Review Rejected 12/17/2020 12/21/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
12/21/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 12/18/2020 12/17/2020
Shannon McGuire
Residential Plan Review Approved 12/17/2020 12/16/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $899.04 $899.04 Paid 12/22/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 12/22/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/22/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/22/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/22/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/22/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $0.00 Paid 10/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 2/25/2021 02/25/2021
Misc
Corrective Action Required
02/25/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Sewer Service Inspection - R Passed 2/25/2021 (11:00) 2/25/2021 02/25/2021
Misc
Partial Correction
02/25/2021
PROVIDE ADDRESS
Water Service Inspection - R Passed 2/25/2021 (11:00) 2/25/2021 02/25/2021
Misc
Partial Correction
02/25/2021
PROVIDE ADDRESS
Footing Inspection - Residential Passed 3/11/2021 03/10/2021
Misc
Resolved
03/10/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Misc
Informational
03/10/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL
Underslab Plumbing Inspection - Residential Failed 3/11/2021 3/11/2021 03/11/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
03/11/2021
- REPAIR OR REPLACED CRUSHED DRIN TILE WEST SIDE- CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Underslab Plumbing Inspection - Residential Passed 3/12/2021 3/12/2021 03/12/2021
R506.2.5 Interior Underslab Drains
Resolved
03/12/2021
All Rough Inspection - Residential Failed 5/10/2021 05/10/2021
Misc
Corrective Action Required
05/10/2021
Note only for ALL-Rough R302- At garage wall needs to be rated as per section 302 both sides.
Electrical Service Inspection Passed 5/19/2021 05/19/2021
Gas Service Inspection - Residential Failed 5/19/2021 05/19/2021
G2417.4.1 Test Pressure
Corrective Action Required
05/19/2021
- PROVIDE MINIMUM 10 PSI FOR 10 MINUTES - INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 5/19/2021 5/19/2021 05/19/2021
Misc
Corrective Action Required
05/10/2021
Note only for ALL-Rough R302- 2018 IRC At garage wall needs to be rated as per section 302 both sides. Tighten anchor bolts basement Provide anchor bolts within 12" of plate break west basement wall Provide 3 studs of braced walls east & west corners of basement Provide CS-PF nailing pattern & straps per plan Dining room & SGD dining room & basement Provide (2) 2 x 10 headers above rear basement windows Provide 1 1/2 bearing deck beam Solid block top plate to roof deck garage & complete west wall Provide 5/8 anchor bolts PFH portal frame garage Anchor bolts shall be in middle 1/3 of width of plate garage Replace LIB rear wall garage Seal electrical penetration top plate foyer Land conductor in a box pantry ceiling Provide roof boots vent to roof master water closet Seal fire blocking fireplace Provide (2) 11 1/4 LVLs corner to corner per plan great room Missing truss lock screw GT foyer/ garage Expose trusses porch & patio
All Rough Inspection - Residential Not Ready 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
05/19/2021
Note only for ALL-Rough R302- 2018 IRC At garage wall needs to be rated as per section 302 both sides. Tighten anchor bolts basement EAST & WEST WALLS Provide anchor bolts within 12" of plate break west basement wall Provide 3 studs of braced walls east & west corners of basement Provide CS-PF nailing pattern & straps per plan Dining room & SGD dining room & basement Provide 1 1/2 bearing deck beam Solid block top plate to roof deck garage & complete west wall Provide 5/8 anchor bolts PFH portal frame garage Anchor bolts shall be in middle 1/3 of width of plate Land conductor in a box pantry ceiling (Done) SEAL UPWARD PENETRATIONS AT ABOVE Provide roof boots vent to roof master water closet Provide (2) 11 1/4 LVLs corner to corner per plan great room Expose trusses porch & patio THJA26 HANGERS TRUSS A-9
Gas Service Inspection - Residential Passed 6/8/2021 6/8/2021 06/08/2021
G2417.4.1 Test Pressure
Resolved
06/08/2021
All Rough Inspection - Residential Not Ready 6/8/2021 6/8/2021 06/08/2021
Misc
Corrective Action Required
06/03/2021
Note only for ALL-Rough R302- 2018 IRC At garage wall needs to be rated as per section 302 both sides. Provide CS-PF nailing pattern & straps per plan basement Provide 1 1/2 bearing deck beam Solid block top plate to roof deck garage & complete west wall ( SEAL BLOCKING ) Land conductor in a box pantry ceiling (Done) SEAL UPWARD PENETRATIONS AT ABOVE Provide roof boots vent to roof master water closet Expose trusses porch & patio THJA26 HANGERS TRUSS A-9
All Rough Inspection - Residential Not Ready 6/22/2021 6/22/2021 06/22/2021
Misc
Corrective Action Required
06/08/2021
Note only for ALL-Rough R302- 2018 IRC At garage wall needs to be rated as per section 302 both sides. ( NAIL PYRO-GUARD PER CODE 6" & 12" ) Provide CS-PF straps per plan basement SGD Provide 1 1/2 bearing deck beam Solid block top plate to roof deck complete west wall ( SEAL BLOCKING ) SEAL UPWARD PENETRATIONS AT PANTRY, SGD BASEMENT, DEAD SPACE FRONT BEDROOM
All Rough Inspection - Residential Not Ready 6/25/2021 6/25/2021 06/25/2021
Misc
Corrective Action Required
06/22/2021
Note only for ALL-Rough R302- 2018 IRC At garage wall needs to be rated as per section 302 both sides. ( NAIL PYRO-GUARD PER CODE 6" & 12" ) Provide CS-PF straps per plan basement SGD ( per plan 2018 IRC PAGE 209 FIGURE R602.10.6.4 HEADER TO JACK STUD STRAP ON BOTH SIDES OF OPENING OPPOSIE SIDE OF SHEATHING) Provide 1 1/2 bearing deck beam Solid block top plate to roof deck complete west wall ( SEAL BLOCKING MASTER BEDROOM & BATH ) SEAL UPWARD PENETRATIONS AT PANTRY, DEAD SPACE FRONT BEDROOM
All Rough Inspection - Residential Failed 7/1/2021 7/1/2021 07/01/2021
Misc
Corrective Action Required
06/25/2021
Provide 1 1/2 bearing deck beam ( Check on Occupancy)
Driveway Inspection Partial 7/14/2021 7/14/2021 07/14/2021
Misc
Informational
07/14/2021
Forms were placed and aggregate was present and compacted. RP 7-14-21
Sidewalk Inspection Partial 7/19/2021 7/19/2021 07/20/2021
Misc
Informational
07/20/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meet ADA standards.
Driveway Inspection Passed 7/23/2021 7/23/2021 07/23/2021
Misc
Informational
07/14/2021
Forms were placed and aggregate was present and compacted. RP 7-14-21
Misc
Informational
07/23/2021
Finished driveway meets LS and ADA specs. RP 7-23-21
All Rough Inspection - Residential Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Resolved
07/30/2021
Occupancy Inspection - Codes Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/13/2021
- pay re-inspection fees. - exterior : sod, final grade, all exterior items. - submit as-graded plot plan. -secure Ac whip. - missing outlet at patio. open box. -deck stairs are over 7 3/4"
Plot Plan Inspection Passed 10/21/2021 10/21/2021
Occupancy Inspection - Codes Residential Temporary C of O 10/21/2021 10/21/2021 10/21/2021
Misc
Corrective Action Required
10/13/2021
- pay re-inspection fees. - exterior : sod, final grade, all exterior items. - submit as-graded plot plan.
Sidewalk Inspection Passed 10/29/2021 10/29/2021 10/29/2021
Misc
Informational
07/20/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meet ADA standards.
Misc
Informational
10/29/2021
Sidewalk meets LS and Ada specs. 10/29 ES
Occupancy Inspection - Codes Residential Full C of O 11/10/2021 11/10/2021 11/10/2021
Misc
Resolved
11/10/2021
Documents & Images
Date Uploaded File Type Document Name
12/15/2020 Application Form W1 #14 - Permit App
12/15/2020 14 WOODSIDE RIDGE ROOF LAYOUT
12/15/2020 W1 #14 - Torino - Mediterranean - Sheets- signed
12/15/2020 2547158 RF SEAL 12012020
12/16/2020 Specifications APPROVED ROOF TRUSS PACKAGE
12/16/2020 Drawing APPROVED ROOF TRUSS LAYOUT
12/16/2020 Plans APPROVED HOUSE PLAN
12/21/2020 Letter Codes Residential Plan Review
12/22/2020 Receipt Receipt for transaction:2020-008167
12/22/2020 Letter DS Building Permit
02/25/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/10/2021 W1-14 Woodside Ridge Footing Inspection
03/10/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter Codes Residential Plan Review
06/03/2021 W1-14 Woodside Ridge Great Room header letter
06/03/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/21/2021 W1-13- Pyro Guard Letter
06/22/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
10/12/2021 Receipt Receipt for transaction:2021-007937
10/13/2021 Letter INSPECTION SUMMARY
10/20/2021 Plot Plan APPROVED AS GRADED PLOT PLAN
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter Codes Temporary Certificate of Occupancy
10/29/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter Codes Final Certificate of Occupancy
11/10/2021 Letter Field Certificate of Occupancy
01/06/2022 W1 #13 - Scope of Work Statement Application
01/06/2022 W1 #13 - Milan - Mediterranean - A3 REVISION 12-20-21- signed
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home