Permit Application Status

PRRES20204544


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204544
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
12/01/2020
12/16/2020
06/12/2021
08/13/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOSH@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/18/2020 12/16/2020
Kim Brennan
Plot Plan Review Approved 12/18/2020 12/16/2020
Kim Brennan
As-graded plot plan
Corrective Action Required
12/16/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Drainage swales/berms
Corrective Action Required
12/16/2020

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
Residential Plan Review Approved 12/18/2020 12/16/2020
Kim Brennan
Residential Plan Review Approved 12/04/2020 12/14/2020
Kim Brennan
Plot Plan Review Rejected 12/04/2020 12/14/2020
Kim Brennan
As-graded plot plan
Corrective Action Required
12/02/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Drainage swales/berms
Corrective Action Required
12/02/2020

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,055.61 $1,055.61 Paid 12/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/16/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/16/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/16/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/16/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/16/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/12/2021 01/27/2021
Misc
Informational
01/27/2021
- 3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER CENTER OF NORTH ( REAR GARAGE FOUNDATION WALL -
Sewer Service Inspection - R Passed 2/23/2021 (11:30) 2/23/2021 02/23/2021
Water Service Inspection - R Passed 2/23/2021 (11:30) 2/23/2021 02/23/2021
Erosion Control Inspection Residential Failed 2/24/2021 02/24/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/24/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN UP STREET -
Underslab Plumbing Inspection - Residential Passed 2/24/2021 2/24/2021 02/24/2021
Piers/Caissons Inspection - Residential Passed 3/29/2021 (9:15) 3/29/2021 03/29/2021
Misc
Informational
03/29/2021
(2) 24 X 36 W/ (4) #4 VERT BARS PER PLAN
All Rough Inspection - Residential Failed 4/6/2021 4/6/2021 04/06/2021
Miscellaneous Correction
Corrective Action Required
04/06/2021
Flashing above horizontal trim @ overhead doors Secure gas line at fireplace Provide 1 roof vent per plan ( 4.00) covered deck Seal upward penetration & fire block between pantry & fridge dead space Seal dead space powder room/bath #2 shower Seal upward penetration between bath #2 & closet Seal upward penetrations sitting room Provide blocking nail off sheathing garage side of front door per code Seal upward penetration laundry room / owners entry Fire block top plate dbl wall laundry ( plan shows 2 x 6 stud wall note 2.12) Seal upward penetration bottom plate laundry Seal upward penetration master closet Seal upward penetrations master water closet Seal penetration top & bottom master shower Complete wiring exhaust fan master bath Provide boca plates VTR behind master bed door Provide nail guard electrical at overhead door ft door side Provide PFH portal framing per plan both sides overhead door (5/8 anchor bolt SQ washers ) Tighten anchor bolts garage Fire block furr out utility sink garage Plans call for continuous 6x6 post covered deck Fire block basement furr out horizontally & vertically every 10' Tighten anchor bolts basement Seal penetrations pex above wet bar & hose bib Address beam bearing on SCH 40 column near sub panel Provide lateral bracing per truss plans Provide flashing horizontal trim under deck
All Rough Inspection - Residential Failed 4/14/2021 4/14/2021 04/14/2021
Miscellaneous Correction
Corrective Action Required
04/06/2021
Secure gas line at fireplace Seal upward penetration & fire block between pantry & fridge dead space Fire block top plate dbl wall laundry ( plan shows 2 x 6 stud wall note 2.12) Provide PFH portal framing per plan both sides overhead door (5/8 anchor bolt SQ washers ) Tighten anchor bolts garage - Plans call for continuous 6x6 post covered deck ( RES LETTER ATTCHED FOR POST SPLICE ) - Fire block basement furr out horizontally & vertically every 10' ( top plate ) Tighten anchor bolts basement Seal upward penetration SCH 40 column near sub panel Provide lateral bracing per truss plans
All Rough Inspection - Residential Passed 4/19/2021 4/19/2021 04/19/2021
Miscellaneous Correction
Resolved
04/19/2021
Electrical Service Inspection Passed 4/29/2021 4/29/2021 04/29/2021
Gas Service Inspection - Residential Passed 4/29/2021 4/29/2021 04/29/2021
Driveway Inspection Partial 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
Forms were placed and aggregate was present and compacted. Forms need to be adjusted to meet ADA compliance. RP 5-25-21
Driveway Inspection Failed 6/4/2021 6/4/2021 06/04/2021
Misc
Corrective Action Required
05/25/2021
Forms were placed and aggregate was present and compacted. Forms need to be adjusted to meet ADA compliance. RP 5-25-21
Misc
Corrective Action Required
06/04/2021
Forms have not been adjusted yet. Please call in for another inspection. RP 6-4-21
Driveway Inspection Partial 6/14/2021 6/14/2021 06/14/2021
Misc
Corrective Action Required
06/04/2021
Forms were placed and aggregate was present and compacted. Forms need to be adjusted to meet ADA compliance. RP 5-25-21
Misc
Corrective Action Required
06/04/2021
Forms have not been adjusted yet. Please call in for another inspection. RP 6-4-21
Misc
Informational
06/14/2021
6/14/21 15:45- 6in depth, rock has been tamped down, forms showed 2% or less I told them to keep the correct slop for the sidewalk.
Driveway Inspection Passed 6/18/2021 6/18/2021 06/18/2021
Misc
Corrective Action Required
06/14/2021
Forms were placed and aggregate was present and compacted. Forms need to be adjusted to meet ADA compliance. RP 5-25-21
Misc
Corrective Action Required
06/14/2021
Forms have not been adjusted yet. Please call in for another inspection. RP 6-4-21
Misc
Informational
06/14/2021
6/14/21 15:45- 6in depth, rock has been tamped down, forms showed 2% or less I told them to keep the correct slop for the sidewalk.
Misc
Informational
06/18/2021
6/18/21 9:05- Drive has been poured, carrying the correct % for the sidewalk, and correct cure was placed.
Occupancy Inspection - Codes Residential Failed 6/23/2021 6/23/2021 06/23/2021
Misc
Corrective Action Required
06/23/2021
-Submit as graded plot plan for review and approval -Sidewalk required per plot plan -Final grade and sod -splash blocks at all sump pump and downspout discharge locations, min 36” discharge from foundation -seal all penetrations through siding, seal along top of AC disconnect and meter can -(2) 1/2” through bolts at each post/beam connection -GFCI protection required at garage wall receptacles, (1) on N wall not tripping when tested -Install kitchen hood, exposed NM at wall -Faulty GFCI receptacles at kitchen counter, Island receptacles -security screws at deck and basement walkout, (2) 3” screws required at each hinge and strike -Breaker lockout at kitchen hood hardwired circuit -Install hot water heater -AFCI protection at master closet receptacles circuit
Sidewalk Inspection Failed 7/7/2021 7/7/2021 07/07/2021
Misc
Corrective Action Required
07/07/2021
Forms were placed and aggregate was present, but not at the required depth. 7-7-21
Misc
Corrective Action Required
07/07/2021
White cure not applied after finishing. Needs to remove and replace sidewalk. RP 7-7-21
Occupancy Inspection - Codes Residential Not Ready 7/12/2021 7/12/2021 07/12/2021
Misc
Corrective Action Required
06/23/2021
-Submit as graded plot plan for review and approval -Sidewalk required per plot plan ( INSPECTION STILL PENDING ) -Final grade and sod -splash blocks at all sump pump and downspout discharge locations, min 36” discharge from foundation -(2) 1/2” through bolts at each post/beam connection -security screws at deck and basement walkout, (2) 3” screws required at each hinge and
Occupancy Inspection - Codes Residential Temporary C of O 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/12/2021
-Sidewalk required per plot plan ( INSPECTION STILL PENDING ) -Final grade and sod -splash blocks at all sump pump and downspout discharge locations, min 36” discharge from foundation -(2) 1/2” through bolts at each post/beam connection - PLOT PLANS SHOWS MANHOLE AT CURB & SIDEWALK - SEWER TRACER WIRE IN BOX AT GRADE - PAY NOT READY FEE
Sidewalk Inspection Passed 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/07/2021
Forms were placed and aggregate was present, but not at the required depth. 7-7-21
Misc
Corrective Action Required
07/14/2021
Still doesn’t have the required depth for aggregate. RP 7-14-21
Misc
Informational
07/14/2021
I inspected the wrong address earlier. Sidewalk meets LS and ADA specs. RP 7-14-21
Sidewalk Inspection Passed 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/14/2021
Forms were placed and aggregate was present, but not at the required depth. 7-7-21
Misc
Corrective Action Required
07/14/2021
Still doesn’t have the required depth for aggregate. RP 7-14-21
Occupancy Inspection - Codes Residential Not Ready 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/14/2021
- SEWER TRACER WIRE IN BOX AT GRADE - PAY NOT READY FEES
Plot Plan Inspection Passed 8/13/2021 08/13/2021
Deck Final Inspection - Residential Passed 8/13/2021 08/13/2021
Occupancy Inspection - Codes Residential Full C of O 8/13/2021 8/13/2021 08/13/2021
Misc
Resolved
08/13/2021
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home