Permit Application Status

PRRES20203284


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203284
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - FINISHED BASEMENT - COVERED DECK - UNCOVERED DECK
09/23/2020
09/28/2020
06/24/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/25/2020 09/28/2020
Dylan Eppert
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
09/25/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) MISSING SMOKE AND COMBO DETECTORS FOR BEDROOM #6 LOCATED IN THE BASEMENT.
Plot Plan Review Approved 09/25/2020 09/25/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,739.26 $1,739.26 Paid 09/28/2020
8331507-Sewer Connection Fee $690.00 $690.00 Paid 09/28/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/28/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/28/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/28/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/28/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/21/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/21/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/21/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/21/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/21/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/21/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 11/2/2020 (11:00) 11/2/2020 11/02/2020
Misc
Corrective Action Required
11/02/2020
- ENGINEER LETTER TO BE RECEIVED AND UPLOADED TO PERMIT THAT DETAILS DRILLED FOUNDATION PIERS
Foundation Inspection - Residential Passed 11/05/2020
Miscellaneous Correction
Informational
11/05/2020
-11’ Foundation wall for garage area. Letter for changes from RES to be submitted to portal
Underslab Plumbing Inspection - Residential Partial 11/17/2020 11/17/2020 11/17/2020
Misc
Informational
11/17/2020
-- 11/17 INSPECTED INTERIOR DRAIN TILE BELOW GARAGE AT SUSPENDED SLAB. OK TO COVER THIS PORTION ONLY
Underslab Plumbing Inspection - Residential Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
—SET INTERIOR DRAIN TILE
Underslab Plumbing Inspection - Residential Passed 12/4/2020 12/4/2020 12/04/2020
Misc
Resolved
12/04/2020
Suspended Slab Inspection Passed 12/9/2020 12/9/2020 12/09/2020
All Rough Inspection - Residential Not Ready 2/17/2021 2/17/2021 02/17/2021
Misc
Corrective Action Required
02/17/2021
INSPECTION DENIED -NO CITY APPROVED HOUSE PLANS OR TRUSS PLANS ON SITE-
All Rough Inspection - Residential Not Ready 2/19/2021 2/19/2021 02/19/2021
Misc
Corrective Action Required
02/17/2021
INSPECTION DENIED -NO CITY APPROVED HOUSE PLANS OR TRUSS PLANS ON SITE- -2/19/21 NO PLANS ON SITE, 2ND NOT READY FEE ADDED-
Electrical Service Inspection Passed 2/23/2021 2/23/2021 02/23/2021
Gas Service Inspection - Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/23/2021
-Complete gas line installation at fireplace
All Rough Inspection - Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/19/2021
-Seal all top and bottom plate penetrations throughout -Install nuts on all anchor bolts in garage -Anchor bolts within middle third of plate in garage -Fireblock DWV chase in garage -Fireblock all tub and shower traps -Fireblock all notches for anchor bolts,HVAC,and columns in rim joist in garage -Seal all through floor penetrations throughout -Block between joists at top plate garage wall -Fireblock HVAC/B vent chase in dining/kitchen -Address cut floor joist for HVAC at dining/kitchen chase 1st floor -Strap cut top plate at HVAC chase dining/kitchen -Fireblock chases in dining room -Fireblock chases in living room -Fireblock vertical to horizontal at fur down in living room -Complete has line install at fireplace -LIB bracing all locations per plans -(2) 2x4 at owner entry door per plans -(2) 2x10 header at fireplace per plans -(2) 1 3/4” x 11 1/4” lvl at kitchen wall supported by (3) 2x4 at ends per plans -(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans -H2.5 truss clip missing at loft -B vent requires 1” clearance from combustibles -Fireblock HVAC chase 2nd floor hall -Flash and install window at 2nd floor bath -Complete electrical at suspended slab in basement -Joist hanger required at dbl joist to rim connection above basement stair landing -Security blocking at basement walkout -Dbl joist hangers required at connection to triple joist at fireplace cantilever, over 4’ -Anchor bolts required within 12” of plate break in basement -Shield service panel from pex water line above panel in basement mech room -Fireblock between top plate and framing/foundation wall in basement, seal any gaps and penetrations through Fireblock material -Fireblock vertical every 10’ between framing/foundation wall in basement, seal any gaps and penetrations through Fireblock -(3) 2x10 header at basement walkout per plans -(2) 2x6 at basement walkout per plans -(3) 2x6 at bed #6 window per plans -3” SCH steel column at pier location”A” basement stairs per plans -Attach deck ledger to house per code -Joist hangers at all deck joists -(2) bolts required at post/beam connection per code *deck incomplete at rough in inspection* -Nail exterior sheathing per plans -Unable to determine 3” grid PFH nailing pattern at garage -Flashing at garage trim
Erosion Control Inspection Residential Failed 3/1/2021 3/1/2021 03/03/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/03/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -RE ESTABLISH AND MAINTAIN EROSION CONTROL SILT FENCE ON NEIGHBORING LOTS OF HOUSE AND ALONG BACK OF LOT AT WOODED CREEK AREA -CLEAN ALL CONSTRUCTION DEBRIS THAT HAS BLOWN OFF SITE ONTO NEIGHBORING LOTS AND AT BACK OF WOODED AREA
All Rough Inspection - Residential Failed 3/5/2021 3/5/2021 03/05/2021
Misc
Corrective Action Required
02/23/2021
-LIB bracing all locations per plans - bottom plate connection bath#5 and pantry -(2) 2x10 header at fireplace per plans -(2) 1 3/4” x 11 1/4” lvl at kitchen wall supported by (3) 2x4 at ends per plans -(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans -Complete electrical at suspended slab in basement -Fireblock between top plate and framing/foundation wall in basement, seal any gaps and penetrations through Fireblock material -3” SCH steel column at pier location”A” basement stairs per plans -Attach deck ledger to house per code -Joist hangers at all deck joists -(2) bolts required at post/beam connection per code *deck incomplete at rough in inspection* -Unable to determine 3” grid PFH nailing pattern at garage -Flashing at garage trim
Gas Service Inspection - Residential Passed 3/5/2021 3/5/2021 03/05/2021
Misc
Resolved
03/05/2021
All Rough Inspection - Residential Failed 3/11/2021 3/11/2021 03/11/2021
Misc
Corrective Action Required
03/05/2021
-LIB bracing bottom plate connection bath#5 and pantry -The (2) 1 3/4” x 11 1/4” lvl at kitchen wall are to be supported by (3) 2x4 stud packs at bearing ends per plans -(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans -Complete electrical at suspended slab in basement -Fireblock between top plate and framing/foundation wall in basement - see E wall basement bedroom at gas line
Sewer Service Inspection - R Passed 3/15/2021 (1:00) 3/15/2021 03/15/2021
Water Service Inspection - R Partial 3/16/2021 3/16/2021 03/16/2021
Misc
Informational
03/16/2021
-PARTIAL INSPECTION ON PEX, MID FRONT YARD TO HOUSE ENTRANCE, OK TO COVER AREA INSPECTED
Water Service Inspection - R Passed 3/19/2021 03/19/2021
Misc
Resolved
03/19/2021
-PARTIAL INSPECTION ON PEX, MID FRONT YARD TO HOUSE ENTRANCE, OK TO COVER AREA INSPECTED
Erosion Control Inspection Residential Failed 03/24/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/03/2021
3-24-2021 Inspection denied due to lack of erosion control -Erosion control requires constant maintenance. Restore silt fence at perimeter of lot or provide acceptable alternative erosion control before any further inspections EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -RE ESTABLISH AND MAINTAIN EROSION CONTROL SILT FENCE ON NEIGHBORING LOTS OF HOUSE AND ALONG BACK OF LOT AT WOODED CREEK AREA -CLEAN ALL CONSTRUCTION DEBRIS THAT HAS BLOWN OFF SITE ONTO NEIGHBORING LOTS AND AT BACK OF WOODED AREA
All Rough Inspection - Residential Not Ready 3/24/2021 3/24/2021 03/24/2021
Misc
Corrective Action Required
03/11/2021
3-24-2021 -Inspection denied due to lack of erosion control- -Erosion control requires constant maintenance. Restore silt fence at perimeter of lot or provide acceptable alternative erosion control before any further inspections -LIB bracing bottom plate connection bath#5 and pantry -The (2) 1 3/4” x 11 1/4” lvl at kitchen wall are to be supported by (3) 2x4 stud packs at bearing ends per plans -(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans -Complete electrical at suspended slab in basement -Fireblock between top plate and framing/foundation wall in basement - see E wall basement bedroom at gas line
All Rough Inspection - Residential Not Ready 3/26/2021 3/26/2021 03/26/2021
Misc
Corrective Action Required
03/24/2021
3-26-2021 -Inspection denied due to lack of erosion control- -Erosion control requires constant maintenance. Restore silt fence at perimeter of lot. Clean all mud and gravel from street -LIB bracing bottom plate connection bath#5 and pantry -The (2) 1 3/4” x 11 1/4” lvl at kitchen wall are to be supported by (3) 2x4 stud packs at bearing ends per plans -(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans -Complete electrical at suspended slab in basement -Fireblock between top plate and framing/foundation wall in basement - see E wall basement bedroom at gas line
Erosion Control Inspection Residential Failed 3/26/2021 3/26/2021 03/26/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/24/2021
3-26-2021 -Inspection denied due to lack of erosion control- -Erosion control requires constant maintenance. Restore silt fence at perimeter of lot. Clean all mud and gravel from street
All Rough Inspection - Residential Failed 3/29/2021 3/29/2021 03/29/2021
Misc
Corrective Action Required
03/26/2021
-(4) stud pack at all girder truss support ends per plans -All truss hangers per plans -Truss bracing per plans (approved truss details not on site, unable to determine at inspection) -Complete electrical at suspended slab in basement -Fireblock between top plate and framing/foundation wall in basement - see E wall basement bedroom at gas line
All Rough Inspection - Residential Passed 3/31/2021 3/31/2021 03/31/2021
Misc
Resolved
03/31/2021
Driveway Inspection Passed 4/12/2021 4/12/2021 04/14/2021
Sidewalk Inspection Passed 4/12/2021 4/12/2021 04/14/2021
Suspended Slab Inspection Passed 05/21/2021
Occupancy Inspection - Codes Residential Failed 5/21/2021 5/21/2021 05/21/2021
Misc
Corrective Action Required
05/21/2021
-Clean mud from street and maintain all erosion control on lot until sod is placed -Resolve outstanding inspection fee(s) before final c of o -Obtain lawn irrigation system permit -Upload engineer letter to permit concerning drilled footing piers as requested at footing inspection 11/2/20 -Final grade -Sod -Address numbers color must contrast with background color -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -Install security screws at deck man door and basement walkout -Grocery pass through door must be self closing, install hardware -Anchor steel column to floor at suspended slab basement -Install smoke at mech room basement -Install landing at deck stairs, more than 7 3/4” from bottom rise
Occupancy Inspection - Codes Residential Failed 5/26/2021 5/26/2021 05/26/2021
Misc
Corrective Action Required
05/21/2021
-Obtain lawn irrigation system permit -Upload engineer letter to permit concerning drilled footing piers as requested at footing inspection 11/2/20 -Final grade -Sod -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -Anchor steel column to floor at suspended slab basement
Footing Inspection - Residential Passed 11/5/2020 (1:00) 05/27/2021
Misc
Resolved
05/27/2021
Occupancy Inspection - Codes Residential Temporary C of O 5/27/2021 5/27/2021 05/27/2021
Misc
Corrective Action Required
05/26/2021
-Obtain lawn irrigation system permit -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation **OK FOR TCO - TCO EXPIRES 6/17/21**
Plot Plan Inspection Failed 06/16/2021
Misc
Corrective Action Required
06/16/2021
-UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE MH 1-A5 AS SHOWN ON THE PLOT PLAN
Occupancy Inspection - Codes Residential Temporary C of O 6/16/2021 6/16/2021 06/16/2021
Misc
Corrective Action Required
05/27/2021
-UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE MH 1-A5 AS SHOWN ON THE PLOT PLAN **OK FOR TCO - TCO EXPIRES 6/25/21**
Erosion Control Inspection Residential Passed 06/24/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/24/2021
Plot Plan Inspection Passed 06/24/2021
Misc
Resolved
06/24/2021
Occupancy Inspection - Codes Residential Full C of O 6/24/2021 6/24/2021 06/24/2021
Misc
Resolved
06/24/2021
Documents & Images
Date Uploaded File Type Document Name
09/23/2020 Application Form RT #20 - PERMIT APP
09/23/2020 RT #20 - TRUSS LAYOUT
09/23/2020 LOT 20 FINAL 9-14-20
09/23/2020 RT #20 - Prescott - Mediterranean - Sheets 9-23-20- signed
09/23/2020 400567
09/25/2020 Specifications APPROVED TRUSS PACKAGE
09/25/2020 Drawing APPROVED TRUSS LAYOUT
09/28/2020 Plans APPROVED HOUSE PLANS
09/28/2020 Receipt Receipt for transaction:2020-006533
09/28/2020 Letter DS Building Permit
10/02/2020 Plot Plan APPROVED PLOT PLAN
11/02/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
02/17/2021 Letter INSPECTION SUMMARY
02/19/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 20 Creekside at Raintree Letter- signed
03/15/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/19/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/21/2021 Receipt Receipt for transaction:2021-003366
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Lot 20 Creekside at Raintree Pier Inspection
05/27/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter Codes Temporary Certificate of Occupancy
06/16/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter Codes Temporary Certificate of Occupancy
06/24/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter Field Certificate of Occupancy
06/24/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home