Permit Application Status

PRRES20202118


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202118
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK ROOF TRUSSES
07/29/2020
08/04/2020
05/14/2021
Locations
Contacts
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
PERMITTING@SUMMITHOMESKC.COM  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/03/2020 08/04/2020
Steve Conrick
Residential Plan Review Approved 08/03/2020 08/03/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $871.64 $871.64 Paid 08/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/04/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/04/2020
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 08/04/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/04/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/04/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/04/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/06/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/06/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/06/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/7/2020 (8:00) 10/7/2020 10/07/2020
Underslab Plumbing Inspection - Residential Passed 11/3/2020 11/3/2020 11/03/2020
Sewer Service Inspection - R Passed 12/14/2020 12/14/2020 12/14/2020
Water Service Inspection - R Partial 12/14/2020 12/14/2020 12/14/2020
Misc
Informational
12/14/2020
-INSPECTED PARTIAL FOR PEX FROM MID POINT OF YARD TO HOUSE ENTRANCE
Water Service Inspection - R Passed 12/15/2020 (10:30) 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
-INSPECTED PARTIAL FOR PEX FROM MID POINT OF YARD TO HOUSE ENTRANCE
Electrical Service Inspection Failed 1/8/2021 1/8/2021 01/08/2021
Misc
Corrective Action Required
01/08/2021
-NO ELECTRICAL INSTALLED IN HOUSE
All Rough Inspection - Residential Not Ready 1/8/2021 1/8/2021 01/08/2021
Misc
Corrective Action Required
01/08/2021
NO INSPECTION PERFORMED -NO CITY APPROVED PLANS AND TRUSS PLANS ON SITE
Erosion Control Inspection Residential Failed 01/21/2021
Misc
Corrective Action Required
01/21/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -maintain gravel filter -no further inspections until issues are resolved
Gas Piping Inspection - Residential Failed 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/11/2021
-SECURE GAS FLEX LINE AT FIREPLACE
Gas Service Inspection - Residential Passed 2/11/2021 2/11/2021 02/11/2021
Electrical Service Inspection Passed 2/11/2021 2/11/2021 02/11/2021
Misc
Resolved
02/11/2021
All Rough Inspection - Residential Failed 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/11/2021
-Seal all top and bottom plate penetration - see master bedroom -Protection plate at DWV bottom plate master water closet -Protection plate at bottom plate pex master shower -Secure gas flex line at fireplace -seal gaps in fireplace Fireblock lid -security blocking - back door, basement walkout -Fireblock between dbl wall top plates in kitchen -Secure all DWV 2” or less at mid point -all truss hangers per plans -all truss bracing per plans -EC#2 hold down per plans -Replace cut out stud at kitchen exterior wall, 16” oc stud per plans at exterior walls -Remove lid at front porch to allow for inspection of truss hold downs -(4) 2x4 stud pack bearing at all girder truss ends per plans -Garage portal header to jack stud strap at dbl car garage per plans R602.10.6.2 -Address overbored sgl and dbl floor joists for DWV, above basement stair landing -Joist hanger required at joist to header connection above basement stair landing -Fireblock vertical every 10’ between framing and foundation wall/framing-seal all gaps at Fireblock and between Fireblock materials and any penetrations through Fireblock -Joist hangers required at all joists connected to triple joist and dbl joists at basement rec room windows/walkout, over 4’ -Joist hanger required at joist to header connection at basement mechanical near furnace, over 4’ -Address (4) floor joists in mech room above main service panel bored for pex less than 2” apart and bored less than 2” from end of joist -W8X24 steel beam bearing on (5) 2” x 6” per plans at basement rec room windows -Unable to verify garage portal 3” grid nail pattern for sheathing to header R602.10.6.2 -Deck ledger connection to house per code -Joist hangers required at all deck joists -(2) bolts required at post/beam connection at deck -Bolt outer ply of rim to ledger and add angel clip to inner ply at deck -Nail exterior sheathing per plans, 6” edge 12” field -Flashing at garage door trim
Erosion Control Inspection Residential Failed 3/4/2021 3/4/2021 03/04/2021
Misc
Resolved
03/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -maintain gravel filter -no further inspections until issues are resolved
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/04/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -SILT FENCE REQUIRED- -CLEAN ALL MUD AND GRAVEL FROM STREET-
All Rough Inspection - Residential Failed 3/4/2021 3/4/2021 03/04/2021
Misc
Corrective Action Required
03/04/2021
INSPECTION DENIED, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -SILT FENCE REQUIRED- -CLEAN ALL MUD AND GRAVEL FROM STREET -Seal all top and bottom plate penetration - see master bedroom -Protection plate at DWV bottom plate master water closet -Protection plate at bottom plate pex master shower -Secure gas flex line at fireplace -seal gaps in fireplace Fireblock lid -security blocking - back door, basement walkout -Fireblock between dbl wall top plates in kitchen -Secure all DWV 2” or less at mid point -all truss hangers per plans -all truss bracing per plans -EC#2 hold down per plans -Replace cut out stud at kitchen exterior wall, 16” oc stud per plans at exterior walls -Remove lid at front porch to allow for inspection of truss hold downs -(4) 2x4 stud pack bearing at all girder truss ends per plans -Garage portal header to jack stud strap at dbl car garage per plans R602.10.6.2 -Address overbored sgl and dbl floor joists for DWV, above basement stair landing -Joist hanger required at joist to header connection above basement stair landing -Fireblock vertical every 10’ between framing and foundation wall/framing-seal all gaps at Fireblock and between Fireblock materials and any penetrations through Fireblock -Joist hangers required at all joists connected to triple joist and dbl joists at basement rec room windows/walkout, over 4’ -Joist hanger required at joist to header connection at basement mechanical near furnace, over 4’ -Address (4) floor joists in mech room above main service panel bored for pex less than 2” apart and bored less than 2” from end of joist -W8X24 steel beam bearing on (5) 2” x 6” per plans at basement rec room windows -Unable to verify garage portal 3” grid nail pattern for sheathing to header R602.10.6.2 -Deck ledger connection to house per code -Joist hangers required at all deck joists -(2) bolts required at post/beam connection at deck -Bolt outer ply of rim to ledger and add angel clip to inner ply at deck -Nail exterior sheathing per plans, 6” edge 12” field -Flashing at garage door trim
Gas Piping Inspection - Residential Passed 3/9/2021 3/9/2021 03/09/2021
Misc
Resolved
03/09/2021
All Rough Inspection - Residential Failed 3/9/2021 3/9/2021 03/09/2021
Misc
Corrective Action Required
03/04/2021
-Fireblock between dbl wall top plates in kitchen -EC#2 hold down per plans -Remove lid at front porch to allow for inspection of truss hold downs -(4) 2x4 stud pack bearing at all girder truss ends per plans -Garage portal header to jack stud strap at dbl car garage per plans R602.10.6.2 -Address overbored sgl and dbl floor joists for DWV, above basement stair landing -Fireblock vertical every 10’ between framing and foundation wall/framing-seal all gaps at Fireblock and between Fireblock materials and any penetrations through Fireblock veritcal and horizontal between top plate and foundation wall/framing -Address (4) floor joists in mech room above main service panel bored for pex less than 2” apart and bored less than 2” from end of joist -W8X24 steel beam bearing on (5) 2” x 6” per plans at basement rec room windows -Unable to verify garage portal 3” grid nail pattern for sheathing to header R602.10.6.2 -(2) bolts required at post/beam connection at deck -Bolt outer ply of rim to ledger and add angel clip to inner ply at deck -Nail exterior sheathing per plans, 6” edge 12” field -Flashing at garage door trim
All Rough Inspection - Residential Failed 3/10/2021 3/10/2021 03/10/2021
Misc
Corrective Action Required
03/09/2021
-EC#2 hold down per plans -Remove lid at front porch to allow for inspection of truss hold downs -(4) 2x4 stud pack bearing at all girder truss ends per plans -Garage portal header to jack stud strap at dbl car garage per plans R602.10.6.2 -Address overbored sgl and dbl floor joists for DWV, above basement stair landing -Address (4) floor joists in mech room above main service panel bored for pex less than 2” apart and bored less than 2” from end of joist -submit letter on fix -Land NM to boxes at basement den windows -Flashing at sgl car garage door trim
All Rough Inspection - Residential Failed 3/12/2021 3/12/2021 03/12/2021
Misc
Corrective Action Required
03/10/2021
-Remove lid at front porch to allow for inspection of truss hold downs -(4) 2x4 stud pack bearing at all girder truss ends per plans - engineer letter references revised changes to A3-A5 pages but those are not included with engineer letter -Garage portal header to jack stud strap at dbl car garage per plans R602.10.6.2 -Address overbored sgl and dbl floor joists for DWV, above basement stair landing - engineer fix not completed - Install CS-16 strap approximately 24” long with (12) 10d x 1-1/2” nails on each floor joist -Address (4) floor joists in mech room above main service panel bored for pex less than 2” apart and bored less than 2” from end of joist - corrections only attempted on (2) of (4) joists called out, follow engineered fix on all joists, Install CS-16 strap approximately 24” long with (12) 10d x 1-1/2” nails on each floor joist -Flashing at sgl car garage door trim *****HOUSE HAS BEEN INSULATED WITHOUT APPROVAL****** ***3/12/21 - 6 ALL ROUGH INSPECTIONS HAVE BEEN PERFORMED, FEES HAVE BEEN ADDED***
All Rough Inspection - Residential Failed 3/19/2021 3/19/2021 03/19/2021
Misc
Corrective Action Required
03/12/2021
**Ok to sheet rock -Address (1) floor joist in mech room above main service panel, covered by duct work bored for pex less than 2” apart and bored less than 2” from end of joist- Install CS-16 strap approximately 24” long with (12) 10d x 1-1/2” nails on each floor joist-location is in unfinished space and should be visible on final *****HOUSE HAS BEEN INSULATED WITHOUT APPROVAL****** ***3/12/21 - 6 ALL ROUGH INSPECTIONS HAVE BEEN PERFORMED, FEES HAVE BEEN ADDED***
Driveway Inspection Partial 3/29/2021 03/29/2021
Misc
Informational
03/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/29/2021 03/29/2021
Misc
Informational
03/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Passed 4/6/2021 4/6/2021 04/06/2021
Misc
Resolved
04/06/2021
Occupancy Inspection - Codes Residential Failed 5/6/2021 5/6/2021 05/06/2021
Misc
Corrective Action Required
05/06/2021
-Final driveway and sidewalk inspections required-contact development services to schedule -Final grade and sod -Cover plate at floor receptacle living room -Install light or cover exposed NM at kitchen ceiling box -Hot water heater must be operational -Cover plates at all receptacles and switches -Complete electrical at AC compressor -(2) through bolts at each post/beam connection at deck -Install exterior light at basement walkout -Seal all penetrations in siding, seal along top of AC disconnect and meter can -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation
Driveway Inspection Passed 4/5/2021 4/5/2021 05/07/2021
Misc
Informational
03/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 4/5/2021 4/5/2021 05/07/2021
Misc
Informational
03/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 5/11/2021 5/11/2021 05/11/2021
Misc
Corrective Action Required
05/06/2021
-Final grade and sod -(2) through bolts at each post/beam connection at deck -R507.5.1 (2) 1/2" diameter through bolts required -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation **OK FOR TCO - TCO EXPIRES 6/1/21**
Plot Plan Inspection Passed 5/13/2021 5/13/2021 05/13/2021
Erosion Control Inspection Residential Passed 05/13/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/13/2021
Occupancy Inspection - Codes Residential Temporary C of O 5/13/2021 5/13/2021 05/13/2021
Misc
Corrective Action Required
05/11/2021
-Obtain lawn irrigation system -(2) through bolts at each post/beam connection at deck -R507.5.1 (2) , 1/2" diameter through bolts required **OK FOR TCO - TCO EXPIRES 6/1/21**
Occupancy Inspection - Codes Residential Full C of O 5/14/2021 5/14/2021 05/14/2021
Misc
Resolved
05/14/2021
Documents & Images
Date Uploaded File Type Document Name
07/29/2020 MN #86 - PERMIT APPLICATION
07/29/2020 LOT 86 FINAL
07/29/2020 MN #86 - Charlotte - Mediterranean - Sheets- signed
07/29/2020 86 MANOR AT STONEY CREEK ROOF LAYOUT- signed
07/29/2020 2387107 RF SEALS 06262020
08/04/2020 APPROVED MN #86 - Charlotte - Mediterranean - Sheets- signed
08/04/2020 APPROVED LOT 86 FINAL
08/04/2020 APPROVED 2387107 RF SEALS 06262020
08/04/2020 APPROVED 86 MANOR AT STONEY CREEK ROOF LAYOUT- signed
08/04/2020 Receipt Receipt for transaction:2020-004941
08/04/2020 Letter DS Building Permit
10/07/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter INSPECTION SUMMARY
03/11/2021 86 Manor at Stoney Creek Field Issues Letter- signed
03/12/2021 Letter INSPECTION SUMMARY
03/18/2021 MN86 - Charlotte - Mediterranean - REVISION 3-9-21- signed
03/18/2021 Approved Plans supplimental approved plans
03/19/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/05/2021 MN86 strap
04/06/2021 Letter INSPECTION SUMMARY
05/06/2021 Receipt Receipt for transaction:2021-002626
05/06/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter Codes Temporary Certificate of Occupancy
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter Codes Temporary Certificate of Occupancy
05/14/2021 Letter Field Certificate of Occupancy
05/14/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home