Summary
PRRES20201715
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
06/24/2020
07/20/2020
12/28/2020
07/02/2021
Locations
Contacts
STEWART BUILDERS LLC, Address:12 SEQUOYAH PT, Phone:(816) 510-7850  
RANDY@STEWARTBUILDERSKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/30/2020 07/08/2020
Steve Conrick
Spot elevations
Corrective Action Required
07/01/2020

Spot elevations, CONTOURS, and drainage flow arrows shall be provided throughout the lot.
Residential Plan Review Approved 06/30/2020 07/01/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,141.77 $1,141.77 Paid 07/20/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/20/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/20/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 07/20/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/20/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 07/20/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 8/18/2020 8/18/2020 08/18/2020
Footing Inspection - Residential Passed 08/18/2020
Sewer Service Inspection - R Passed 8/28/2020 (9:45) 8/28/2020 08/28/2020
Water Service Inspection - R Partial 8/28/2020 8/28/2020 08/28/2020
Water Service Inspection - R Passed 8/28/2020 (1:15) 8/28/2020 08/28/2020
Piers/Caissons Inspection - Residential Failed 9/23/2020 (9:00) 9/23/2020 09/23/2020
Misc
Corrective Action Required
09/23/2020
36” depth required for (3) piers
Piers/Caissons Inspection - Residential Passed 9/24/2020 (8:00) 9/24/2020 09/24/2020
Misc
Resolved
09/24/2020
Electrical Service Inspection Passed 1/28/2021 1/28/2021 01/28/2021
Gas Piping Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
Gas Service Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
All Rough Inspection - Residential Failed 1/28/2021 1/28/2021 01/28/2021
Misc
Corrective Action Required
01/28/2021
-City approved stamped plans required on site -Joist hanger required at tail joist connection to attic access in garage, over 4’ -Joist hangers required on joists/header between dbl and single car door in garage, 4’ -Joist hanger at ceiling joist garage entry water closet -Garage PFH portal framing per plans S2.0 detail, 5/8" ANCHOR BOLT PER R403.1.6 W/ 2"x2"x3/16" PLATE WASHER -Protection plate at master bath vanity DWV -Plans show W18x35 steel beam in garage - no engineered girder truss documentation in permit -Clarify (2) locations beam as spec’d in great room as shown in plans -DBL wall kitchen per plans -No approved engineered floor system plans in permit -submit for approval and have approved copies on site -Basement bedroom #3, Bocca protection plate at DWV and pex location for bath at top plate -Seal pex top plate penetration bed #3 -Fireblock deadspace bedroom #3 between foundation and bath -Security blocking at basement walkout -Deck beam to column connection per plans S1.3 -Cannot verify garage portal hold down straps embedded into concrete, required per R602.10.6.2, see detail S2.0, also cannot verify 3” nailing pattern for sheathing to header
All Rough Inspection - Residential Failed 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/11/2021
-Cannot verify garage portal hold down straps embedded into concrete, required per R602.10.6.2, see detail S2.0 ***OK TO INSULATE AND ROCK***
Occupancy Inspection - Codes Residential Failed 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/11/2021
-Final deck inspection at occupancy -Deck beam to column connection per plans S1.3
Misc
Corrective Action Required
02/11/2021
-Final deck inspection at occupancy -Deck beam to column connection per plans S1.3
Misc
Resolved
02/11/2021
All Rough Inspection - Residential Passed 2/16/2021 2/16/2021 02/16/2021
Misc
Resolved
02/16/2021
Sidewalk Inspection Partial 3/24/2021 3/24/2021 03/24/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Partial 03/24/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/31/2021 3/31/2021 04/01/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/31/2021 3/31/2021 04/01/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Failed 5/25/2021 5/25/2021 05/25/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/25/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN EROSION CONTROL AT REAR OF LOT, NEIGHBORING LOT AT REAR EXPERIENCING SILT FENCE RUNOFF ON PROPERTY
Deck Final Inspection - Residential Failed 6/14/2021 6/14/2021 06/14/2021
Miscellaneous Correction
Corrective Action Required
06/14/2021
Provide Simpson end post caps and post bases per option 2 of detail 5 on S1.3 or continous posts with let in beam and through bolts per option 1
Deck Final Inspection - Residential Passed 6/15/2021 6/15/2021 06/15/2021
Miscellaneous Correction
Resolved
06/15/2021
Plot Plan Inspection Passed 07/02/2021
Erosion Control Inspection Residential Passed 07/02/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/02/2021
Occupancy Inspection - Codes Residential Full C of O 7/2/2021 7/2/2021 07/02/2021
Misc
Resolved
06/15/2021
Misc
Resolved
06/15/2021
Documents & Images
Date Uploaded File Type Document Name
06/24/2020 License_Tax_Application
06/24/2020 Residental Permit Application_1 (002)
06/24/2020 Lot 57 SVF Plot PLan
06/24/2020 DW Permit Plan Mackenzie II 3129 SW Blue Ribbon Lot 57 Summit View Farms
06/25/2020 Lot 57 SVF Plot Plan
07/01/2020 APPROVED DW Permit Plan Mackenzie II 3129 SW Blue Ribbon Lot 57 Summit View Farms
07/01/2020 Letter Codes Residential Plan Review
07/07/2020 Lot 57 SVF Plot Plan Revised
07/08/2020 APPROVED Lot 57 SVF Plot Plan Revised
07/20/2020 Receipt Receipt for transaction:2020-004562
07/20/2020 Letter DS Building Permit
07/25/2020 M L Crose 3129 SW Blue Ribbon LSMO SVF Lot 57 Stewart P 2020-1715 3rd Party Footing Inspection Report 7-24-20
08/18/2020 Letter INSPECTION SUMMARY
08/18/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/24/2020 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/08/2021 Approved Plans Approved I-Joist Layout
02/08/2021 Approved Plans Approved Truss Package
02/08/2021 Approved Plans Approved I-Joist Layout
02/08/2021 Approved Plans Approved Drawings
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/16/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 deck post detail
06/15/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter Field Certificate of Occupancy
07/02/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.