Permit Application Status

PRRES20201084


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201084
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - UNFINISHED BASEMENT
04/29/2020
05/27/2020
03/16/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/05/2020 05/22/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
05/01/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Drainage swales
Corrective Action Required
05/01/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
Planning Review (RES) Approved 05/05/2020 05/21/2020
Dylan Eppert
Residential Plan Review Approved 05/05/2020 05/01/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,348.38 $1,348.38 Paid 05/26/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 05/26/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 05/26/2020
Water Meter Fee $425.02 $425.02 Paid 05/26/2020
Right of Way Permit Fee $80.00 $80.00 Paid 05/26/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/26/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/16/2020 (10:30) 6/16/2020 06/16/2020
Water Service Inspection - R Passed 6/26/2020 6/26/2020 06/26/2020
Underslab Plumbing Inspection - Residential Passed 6/29/2020 6/29/2020 06/29/2020
Footing Inspection - Residential Passed 6/4/2020 6/4/2020 07/07/2020
Electrical Service Inspection Failed 8/27/2020 8/27/2020 08/27/2020
Misc
Corrective Action Required
08/27/2020
- Color code UFER ground
Gas Piping Inspection - Residential Failed 8/27/2020 8/27/2020 08/27/2020
Misc
Corrective Action Required
08/27/2020
- Secure gas flex line at fireplace
Gas Service Inspection - Residential Passed 8/27/2020 8/27/2020 08/27/2020
All Rough Inspection - Residential Failed 8/27/2020 8/27/2020 08/27/2020
Misc
Corrective Action Required
08/27/2020
- Seal all top plate penetrations - garage - Nail header to supporting floor joists at HVAV chase in pantry - Protection plate at refrigerator pex in kitchen - Fireblock all tub traps - Secure gas flex line at fireplace - Structural straps required at top and bottom plates bored 50% or more on exterior walls and interior bearing walls - (2) 2x10 header above bedroom door and closet door per plans bedroom #5 interior bearing wall - EC#2 per plans - Truss hangers per plans - front porch - Complete bath fan exhaust 2nd floor bath - Complete HVAC duct master bath - Color code UFER ground - Support DWV in basement SW side, traps not support 48” o.c. - (3) 2x10 joists between steel beams in basement for 1st floor bearing per plans
All Rough Inspection - Residential Failed 9/1/2020 9/1/2020 09/01/2020
Misc
Corrective Action Required
08/27/2020
- Nail header ends to supporting floor joist at HVAV chase in pantry - (2) 2x10 header above bedroom door and closet door per plans bedroom #5 interior bearing wall - Complete bath fan exhaust 2nd floor bath - Color code UFER ground
Gas Piping Inspection - Residential Passed 09/01/2020
Misc
Resolved
09/01/2020
All Rough Inspection - Residential Passed 9/2/2020 9/2/2020 09/02/2020
Misc
Resolved
09/02/2020
- Nail header ends to supporting floor joist at HVAV chase in pantry - (2) 2x10 header above bedroom door and closet door per plans bedroom #5 interior bearing wall - Complete bath fan exhaust 2nd floor bath - Color code UFER ground
Misc
Informational
09/02/2020
9/2/2020 ALL CORRECTIONS MADE- OK TO INSULATE & ROCK
Electrical Service Inspection Passed 9/2/2020 9/2/2020 09/02/2020
Misc
Resolved
09/02/2020
- Color code UFER ground
Driveway Inspection Passed 9/16/2020 (Ready Now) 9/16/2020 09/16/2020
Misc
Informational
09/16/2020
On Wednesday 9-16-2020. A driveway inspection was performed. Driveway passed inspection.
Plot Plan Inspection Passed 10/13/2020 10/13/2020
Occupancy Inspection - Codes Residential Failed 12/30/2020 12/30/2020 12/30/2020
Misc
Corrective Action Required
12/30/2020
-sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Guardrail required at front porch, more than 30” from grade -Final sidewalk inspection -seal all penetrations in siding, seal along top of AC disconnect and meter can -Label dedicates receptacles in garage and unfinished basement as not GFCI protected -access required for jacuzzi tub motor in master bath -AFCI protection required at washer circuit -Egress ladder required at basement well -Address NM against b vent at furnace, minimum 1” clearance required
Sidewalk Inspection Passed 9/16/2020 (Ready Now) 9/16/2020 01/04/2021
Misc
Informational
01/04/2021
On 9-16-2020 a sidewalk inspection was conducted and passed inspection.
Occupancy Inspection - Codes Residential Failed 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
12/30/2020
-sod -As graded plot plan failed due to stock piles from trenching on adjacent lot-recall when corrected -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Guardrail required at front porch, more than 30” from grade -Address NM against b vent at furnace, minimum 1” clearance required-Use permanent fastening method
Occupancy Inspection - Codes Residential Failed 01/21/2021
Misc
Corrective Action Required
01/21/2021
-sod -As graded plot plan failed due to stock piles from trenching on adjacent lot-recall when corrected -Address NM against b vent at furnace, minimum 1” clearance required-Use permanent fastening method
Plot Plan Inspection Failed 1/21/2021 01/21/2021
Misc
Corrective Action Required
01/21/2021
-Unable to verify grading due to stockpiles from trenching at adjacent lot
Plot Plan Inspection Passed 3/16/2021 3/16/2021 03/16/2021
Misc
Resolved
03/16/2021
-Unable to verify grading due to stockpiles from trenching at adjacent lot
Occupancy Inspection - Codes Residential Full C of O 3/16/2021 3/16/2021 03/16/2021
Misc
Resolved
03/16/2021
-sod -As graded plot plan failed due to stock piles from trenching on adjacent lot-recall when corrected -Address NM against b vent at furnace, minimum 1” clearance required-Use permanent fastening method
Documents & Images
Date Uploaded File Type Document Name
04/29/2020 Application Form HT #38 - PERMIT APP
04/29/2020 LOT 38 FINAL
04/29/2020 38 HAWTHORNE RIDGE 2ND FLOOR LAYOUT- signed
04/29/2020 38 HAWTHORNE RIDGE 1ST FLOOR LAYOUT- signed
04/29/2020 400235
04/29/2020 HT #38 - Canterbury - Modern Farm House - Sheets- signed
05/01/2020 Plans APPROVED HOUSE PLANS 1524 SUGAR TREE
05/01/2020 Specifications APPROVED TRUSS PACKAGE
05/01/2020 Drawing APPROVED 1ST FLOOR LAYOUT
05/01/2020 Drawing APPROVED 2ND FLOOR LAYOUT
05/21/2020 Letter Codes Residential Plan Review
05/22/2020 APPROVED ELEVATIONS
05/26/2020 Receipt Receipt for transaction:2020-002362
05/27/2020 Letter DS Building Permit
05/27/2020 Plot Plan Approved Plot Plan
06/02/2020 Lot 38 Hawthorne Ridge - Subgrade Inspection - Spread Footing
06/04/2020 Letter Lot 38 Hawthorne Ridge -Footing Inspection
06/11/2020 Letter Lot 38 Hawthorne Ridge -Wall Inspection
06/16/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
10/12/2020 Plot Plan APPROVED AS-BUILT
10/13/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
12/30/2020 Letter INSPECTION SUMMARY
01/20/2021 Plot Plan APPROVED AS-BUILT
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter Field Certificate of Occupancy
03/16/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home