Permit Application Status

PRRES20201016


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201016
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK
04/21/2020
04/28/2020
10/21/2020
11/07/2023
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/30/2020 04/28/2020
Steve Conrick
Basement egress
Corrective Action Required
04/28/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Residential Plan Review Approved 04/30/2020 04/28/2020
Steve Conrick
Plot Plan Review Rejected 04/24/2020 04/24/2020
Steve Conrick
Basement egress
Corrective Action Required
04/24/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Residential Plan Review Approved 04/24/2020 04/24/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,309.29 $1,309.29 Paid 04/28/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/28/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/28/2020
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 04/28/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/28/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 04/28/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 04/28/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/22/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/26/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/12/2020 5/12/2020 05/12/2020
Erosion Control Inspection Residential Failed 5/12/2020 05/12/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/12/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Not Ready 6/22/2020 6/22/2020 06/22/2020
Misc
Corrective Action Required
06/22/2020
NO INSPECTION PERFORMED - DWV HAS NOT BEEN COMPLETED, MATERIAL PILED UP IN CENTER OF FLOOR - NOT READY FEE
Underslab Plumbing Inspection - Residential Passed 6/23/2020 6/23/2020 06/23/2020
Misc
Resolved
06/23/2020
Sewer Service Inspection - R Passed 8/5/2020 (9:45) 8/5/2020 08/05/2020
Water Service Inspection - R Passed 8/6/2020 (8:45) 8/6/2020 08/06/2020
Gas Service Inspection - Residential Not Ready 8/11/2020 8/11/2020 08/11/2020
Misc
Corrective Action Required
08/11/2020
NOT READY FOR INSPECTION, INSTALL GAS FIREPLACE NOT READY FEE
Electrical Service Inspection Passed 9/11/2020 9/11/2020 09/11/2020
Gas Piping Inspection - Residential Passed 9/11/2020 9/11/2020 09/11/2020
Gas Service Inspection - Residential Failed 9/11/2020 9/11/2020 09/11/2020
Misc
Corrective Action Required
08/11/2020
GAS PRESSURE AT 6 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 9/11/2020 9/11/2020 09/11/2020
Misc
Corrective Action Required
09/11/2020
- Garage PFH per plans-5/8” anchor bolt w/ 2” x 2” x 3/16” plate washer - Joist hanger tail joist at attic access in garage - Secure ward flex at fireplace - Terminate NM (romex) at ceiling W wall by fireplace 1st floor - Security blocking at back door - Pex within 6” of recessed can light in kitchen - relocate or shield - Joist hanger at sgl joist to lvl connection above kitchen pantry - Protection plates at romex bottom plate within 1 1/4” from end of framing member - dining room, master bedroom - HSS columns at steel beam in garage per plans - Address rafters landing on blocks - submit engineer letter - Steel beam column support basement per plan pier locations - conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. - Gas pressure at 6 psi, must maintain 10 psi for 15 minutes
All Rough Inspection - Residential Failed 10/21/2020 10/21/2020 10/21/2020
Misc
Corrective Action Required
09/11/2020
- Secure electric box and romex W side garage wall
Gas Service Inspection - Residential Passed 10/21/2020
Misc
Resolved
10/21/2020
All Rough Inspection - Residential Passed 10/23/2020 10/23/2020 10/23/2020
Misc
Resolved
10/23/2020
- Secure electric box and romex W side garage wall
Miscellaneous Correction
Corrective Action Required
10/23/2020
-CLEARLY MARK ADDRESS-
Driveway Inspection Partial 11/19/2020 (P.M.) 11/19/2020 11/19/2020
Misc
Informational
11/19/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 11/26/2020 11/26/2020 11/30/2020
Misc
Informational
11/19/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Plot Plan Inspection Passed 01/26/2021
Piers/Caissons Inspection - Residential Passed 01/26/2021
Occupancy Inspection - Codes Residential Failed 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/26/2021
-Resolve outstanding inspection fee(s) before final c of o -Emergency egress ladder at basement well -E3902.16 AFCI protection required - branch circuits that supply 120 volt, single phase, 15 and 20 volt amp outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and any similar areas. -Basement stair handrail must terminate to a newel post or safety terminal at lowest riser R311.7.8.4 -complete landscaping/sod at front of house -downspout discharge minimum 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 1/28/2021 1/28/2021 01/28/2021
Misc
Corrective Action Required
01/26/2021
-complete landscaping/sod at front of house -downspout discharge minimum 36” from foundation OK FOR TCO - TCO EXPIRES 2/11/21
Occupancy Inspection - Codes Residential Full C of O 11/7/2023 11/07/2023
Misc
Resolved
11/07/2023
-complete landscaping/sod at front of house -downspout discharge minimum 36” from foundation OK FOR TCO - TCO EXPIRES 2/11/21
Documents & Images
Date Uploaded File Type Document Name
04/21/2020 exciseapplication
04/21/2020 Lees Summit Residental Permit Application 1808 blackstone
04/21/2020 1808 blackstone stamped city plan lot 98 napa
04/21/2020 LOT 98 FINAL
04/21/2020 1808 blackstone stamped city plan lot 98 napa
04/24/2020 Letter Codes Residential Plan Review
04/28/2020 APPROVED LOT 98 CITY
04/28/2020 APPROVED 1808 blackstone stamped city plan lot 98 napa0
04/28/2020 Receipt Receipt for transaction: 2020-001766
04/28/2020 Letter DS Building Permit
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
06/22/2020 Letter INSPECTION SUMMARY
06/22/2020 Receipt Receipt for transaction:2020-003421
06/23/2020 Letter INSPECTION SUMMARY
08/05/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/06/2020 Engineer Report/Study Final_2020.07.16_DPier_LSMO_Concrete Design
08/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
10/21/2020 APPROVED
10/21/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Receipt Receipt for transaction:2021-000408
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter Codes Temporary Certificate of Occupancy
11/07/2023 Letter Codes Final Certificate of Occupancy
11/07/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home