Permit Application Status

PRRES20200534


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200534
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO LAWN IRRIGATION PERMIT INCLUDED WITH THIS APPLICATION
03/02/2020
03/30/2020
12/04/2020
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
PAUL@BELLAHHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/04/2020 03/27/2020
Kim Brennan
Legal description
Corrective Action Required
03/25/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Should be SW versus SE on both streets
Right-of-way
Corrective Action Required
03/25/2020

The right-of-way with dimensions must be provided on the plot plan. Please show the 20 ft R/W for the alley
Sidewalks
Corrective Action Required
03/25/2020

Sidewalks with dimensions must be provided on the plot plan. Is there an ADA ramp at the corner? If so, please show
Curb elevation
Corrective Action Required
03/25/2020

The elevation at top of curb at end of driveway and at lot corners adjacent to street must be provided on the plot plan.
Misc
Corrective Action Required
03/26/2020

Please show contours for finished elevations
Residential Plan Review Approved 03/04/2020 03/02/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $971.36 $971.36 Paid 03/30/2020
Right of Way Permit Fee $80.00 $80.00 Paid 03/30/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/30/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 03/30/2020
Water Meter Fee $425.02 $425.02 Paid 03/30/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 03/30/2020
Additional Permit Fee $30.00 $30.00 Paid 03/30/2020
Valuation Fee New Single Family $42.47 $42.47 Paid 08/18/2020
$1,013.83
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/2/2020 04/16/2020
Corrective Action Required
04/16/2020
3rd party footing signed & stamped by David P Ainsworth, P.E. - notes: ufer ground located north basement sidewall 10" E of the rear garage wall
Underslab Plumbing Inspection - Residential Passed 4/23/2020 4/23/2020 04/23/2020
Erosion Control Inspection Residential Failed 4/23/2020 04/23/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/23/2020
- PROVIDE GRAVEL FILTER - - MAINTAIN SILT FENCE -
Sewer Service Inspection - R Passed 5/13/2020 (10:30) 5/13/2020 05/13/2020
Water Service Inspection - R Passed 5/14/2020 (11:15) 5/14/2020 05/14/2020
Electrical Service Inspection Passed 7/20/2020 7/20/2020 07/20/2020
Gas Piping Inspection - Residential Passed 7/20/2020 07/20/2020
Gas Service Inspection - Residential Passed 7/20/2020 7/20/2020 07/20/2020
All Rough Inspection - Residential Failed 7/20/2020 7/20/2020 07/20/2020
Misc
Corrective Action Required
07/20/2020
- SHIELD ELECTRICAL BOX IN PLENUM IN HALL AT MASTER - - PROVIDE JOIST HANGERS ABOVE SUMP PUMP - - SEAL BORES IN TOP & BOTTOM PLATE AT MASTER SHOWER - - BED # 2 PROVIDE (3) 2 X 12 FOR ROOF SUPPORT PER PLAN - - PROVIDE PFH PORTAL FRAMING GARAGE DOORS PER PLAN DETAIL 1 S3.0 - - SHEATH GARAGE FACE OF REAR WALL PER FRAMING NOTE #1 - - ADDRESS RAFTERS LANDING ON BLOCKS THROUGHOUT -
All Rough Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
Misc
Resolved
07/22/2020
All Rough Inspection - Residential Failed 9/1/2020 9/1/2020 09/01/2020
Misc
Corrective Action Required
09/01/2020
Fireblock finished basement area stud walls at maximum 10’ intervals horizontally
All Rough Inspection - Residential Passed 9/3/2020 09/03/2020
Misc
Resolved
09/03/2020
Fireblock finished basement area stud walls at maximum 10’ intervals horizontally
Sidewalk Inspection Partial 9/10/2020 9/10/2020 09/14/2020
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted. Talked with Terry about connecting to the ADA ramp and the storm box. RP 9-14-20
Sidewalk Inspection Passed 9/18/2020 9/18/2020 09/18/2020
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted. Talked with Terry about connecting to the ADA ramp and the storm box. RP 9-14-20
Misc
Informational
09/18/2020
Finished sidewalk meets LS and ADA specs. RP 9-18-20
Occupancy Inspection - Codes Residential Failed 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/29/2020
-Driveway inspection pending, contact development services to resolve this issue -Submit as graded plot plan for review -Final grade per approved as graded plot and sod. Plot inspection required before the installation of sod -Seal all exterior penetrations -Provide tamper resistant Schrader valve caps at condensing unit -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation and 5’ from property line -Minimum 6” clearance from wood siding to grade below -Grade must fall minimum 6” in the first 10’ from foundation -Remove paper from exposed batt insulation in unfinished basement area -faulty deadbolt at side entry door
Occupancy Inspection - Codes Residential Temporary C of O 11/2/2020 11/2/2020 11/02/2020
Misc
Corrective Action Required
10/29/2020
-Submit as graded plot plan for review -Final grade per approved as graded plot and sod. Plot inspection required before the installation of sod -Seal all exterior penetrations -Provide tamper resistant Schrader valve caps at condensing unit -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation and 5’ from property line -Minimum 6” clearance from wood siding to grade below -Grade must fall minimum 6” in the first 10’ from foundation or provide swale between properties
Occupancy Inspection - Codes Residential Full C of O 12/4/2020 12/4/2020 12/04/2020
Misc
Resolved
12/04/2020
-Submit as graded plot plan for review -Final grade per approved as graded plot and sod. Plot inspection required before the installation of sod -Seal all exterior penetrations -Provide tamper resistant Schrader valve caps at condensing unit -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation and 5’ from property line -Minimum 6” clearance from wood siding to grade below -Grade must fall minimum 6” in the first 10’ from foundation or provide swale between properties
Plot Plan Inspection Passed 11/6/2020 12/04/2020
Misc
Resolved
12/04/2020
-as built plot reflects on site conditions but as stated in TCO inspection report, grade must fall minimum 6” in the first 10’ from foundation per code or provide swale between properties.
Plot Plan Inspection Passed 12/04/2020
Misc
Resolved
12/04/2020
-as built plot reflects on site conditions but as stated in TCO inspection report, grade must fall minimum 6” in the first 10’ from foundation per code or provide swale between properties.
Documents & Images
Date Uploaded File Type Document Name
03/25/2020 Plans Lawn Sprinkler release for lot 108 Pergoal Park
03/25/2020 Scope of Work Building permit and license tax form for lot 108 Pergola Park
03/26/2020 Letter Codes Residential Plan Review
03/27/2020 Plans Drawings for Pergola Park Lot 108
03/27/2020 Plot Plan Plot Plan for 3201 SW Mary St.
03/30/2020 Receipt Receipt for transaction: 2020-001314
03/30/2020 Letter DS Building Permit
04/08/2020 Engineer Report/Study M L Crose 3201 SW Mary St LSMO Bellah Permit 2020-0534 3rd Party Footing Inspection Report 4-2-20
04/16/2020 Letter INSPECTION SUMMARY
04/23/2020 Letter INSPECTION SUMMARY
04/23/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter Framing Issues Report 7-21-20
08/18/2020 Drawing Approved Basement Plan
08/18/2020 Receipt Receipt for transaction:2020-005353
09/01/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter Codes Temporary Certificate of Occupancy
11/05/2020 Plot Plan APPROVED AS-BUILT
11/06/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter Codes Final Certificate of Occupancy
12/04/2020 Letter Field Certificate of Occupancy
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home