Summary
PRRES20193622
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK SUSPENDED SLAB STOP WORK ORDER generated on 03/03/2020 12:00 AM by username 'Mark Harding'. STOP WORK ORDER removed on 05/12/2020 12:00 AM by username 'Mark Harding'.
12/16/2019
12/30/2019
01/21/2021
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
MARKV@ROBWASHAMHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/18/2019 12/19/2019
Kim Brennan
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
12/16/2019

Identify roof covering material (IRC Section R905)
10 Combustion air
Corrective Action Required
12/16/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Misc
Corrective Action Required
12/16/2019

Plans show a walk-out basement however a walk-out is not approved for this lot. It will need to be changed to a daylight basement.
Miscellaneous Correction
Corrective Action Required
12/16/2019

Plans show optional bathroom. Pllease indicate if this will be finished or unfinished.
Miscellaneous Correction
Corrective Action Required
12/16/2019

Plans show a suspended slab but application does not. Please specify.
Plot Plan Review Approved 12/18/2019 12/19/2019
Kim Brennan
Basement elevation
Corrective Action Required
12/16/2019

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) The MDP calls for a daylight basement and not a walk-out.
Basement egress
Corrective Action Required
12/16/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
12/16/2019

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Plot Plan shows 963.5 and the MDP shows 965.20.
City infrustructure
Corrective Action Required
12/16/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please label all infrastructure including stoirmwater
As-graded plot plan
Corrective Action Required
12/16/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $912.54 $912.54 Paid 12/30/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/30/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/30/2019
8331507-Sewer Connection Fee $480.00 $480.00 Paid 12/30/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/30/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/30/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 2/18/2020 2/18/2020 02/18/2020
Water Service Inspection - R Passed 2/19/2020 (9:45) 2/19/2020 02/19/2020
Underslab Plumbing Inspection - Residential Passed 2/20/2020 2/20/2020 02/20/2020
Footing Inspection - Residential Failed 3/3/2020 3/3/2020 03/03/2020
Misc
Corrective Action Required
03/03/2020
No footing inspections performed on this permit. see Engeers letters from RES> placing a Stop Construction on the permit. Insulation is not installed per code. contact Mark Harding, see email to RES.
All Rough Inspection - Residential Partial 5/13/2020 05/13/2020
Misc
Informational
05/13/2020
- Inspected garage portal -
Footing Inspection - Residential Failed 3/5/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
03/03/2020
- Foam insulation at back of house damaged and missing under door -
Suspended Slab Inspection Passed 5/18/2020 (1:30) 5/18/2020 05/18/2020
Erosion Control Inspection Residential Failed 06/04/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 6/9/2020 6/9/2020 06/09/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Gas Piping Inspection - Residential Passed 6/24/2020 6/24/2020 06/24/2020
Electrical Service Inspection Passed 6/24/2020 6/24/2020 06/24/2020
Gas Service Inspection - Residential Failed 6/24/2020 6/24/2020 06/24/2020
Miscellaneous Correction
Corrective Action Required
06/24/2020
-PRESSURE GAUGE IS BROKEN AT TIME OF INSPECTION. PLEASE REPLACE FOR RE-INSPECTION
All Rough Inspection - Residential Failed 6/24/2020 6/24/2020 06/24/2020
Misc
Informational
05/13/2020
- Inspected garage portal -
Miscellaneous Correction
Corrective Action Required
06/24/2020
Tighten anchor bolts in garage Protect NM in garage by laundry room Fire stop joint of double wall top plate in laundry Nail corners and wall intersections per code Missing Smoke and co2 detector outside of bedrooms Seal around flue in chase wall in hall Block joists above wall at cantilevers Missing hanger on joist southeast corner at cantilever Fire block beam webs Nail double 2x10 joists in basement family room Provide treated wood where in contact with concrete in the storm shelter Tighten anchor bolts in basement Fire stop furred out wall at walk in and basement mechanical room Pressure valve on gas gauge broken Fire stop floor joist and wall top plate near subpanel Fire stop Recess gap in sheathing in mechanical room with sub panel Provide hanger connections where deck joist meets corner of house
Gas Service Inspection - Residential Passed 07/01/2020
Miscellaneous Correction
Resolved
07/01/2020
-PRESSURE GAUGE IS BROKEN AT TIME OF INSPECTION. PLEASE REPLACE FOR RE-INSPECTION
All Rough Inspection - Residential Failed 7/1/2020 7/1/2020 07/01/2020
Misc
Informational
06/24/2020
- Inspected garage portal -
Miscellaneous Correction
Corrective Action Required
06/24/2020
**OK TO INSULATE EXCEPT WHERE CORRECTIONS ARE NEEDED. DO NOT SHEET ROCK** -Fire block beam webs-wall by furnace and north mechanical room off of stairs -Tighten anchor bolts in basement-south wall by closet door and north bedroom
All Rough Inspection - Residential Passed 7/2/2020 7/2/2020 07/02/2020
Misc
Informational
07/01/2020
- Inspected garage portal -
Miscellaneous Correction
Resolved
07/02/2020
**OK TO INSULATE EXCEPT WHERE CORRECTIONS ARE NEEDED. DO NOT SHEET ROCK** -Fire block beam webs-wall by furnace and north mechanical room off of stairs -Tighten anchor bolts in basement-south wall by closet door and north bedroom
Driveway Inspection Passed 8/20/2020 8/20/2020 08/20/2020
Misc
Informational
08/20/2020
On Thursday, 8-20-2020. A driveway inspection was conducted and found the sub-grade and forming to meet city standards. Inspection passes
Erosion Control Inspection Residential Passed 09/29/2020
Misc
Resolved
09/29/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site
Occupancy Inspection - Codes Residential Failed 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
07/02/2020
-Irrigation permit required -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation -Footing inspection was never passed and no record of third party inspection available at time of inspection, provide engineered solution -Grade must fall minimum 6” in the first 10’ from foundation, rear of structure -minimum 6” clearance from wood siding to grade below -Seal all exterior penetrations -Garage/dwelling separation door must self close and self latch -Remove trash and construction debris -Label dedicated circuits at receptacle as non-GFCI protected in garage unfinished basement area -Complete stairs from garage into dwelling -Secure lawn irrigation piping to foundation wall -four 3” wood screws in basement exterior door strike -Weatherstripping at basement exterior door -Locate and expose manhole lid front of Lot north side as shown on plot plan DECK -Beam/post connection per code, through bolts -Provide engineered solution for joist/ledger connection to house at corners -Noncontinuous posts supporting covered deck, provide city approved plans at re-inspection to ensure proper attachment
Deck Final Inspection - Residential Failed 10/29/2020
Miscellaneous Correction
Corrective Action Required
07/02/2020
-PROVIDE ENGINEERED SOLUTION FOR JOIST/LEDGER CONNECTION AT CORNERS OF HOUSE
Plot Plan Inspection Failed 11/10/2020 10/29/2020
Erosion Control Inspection Residential Passed 10/29/2020
Misc
Resolved
10/29/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site
Footing Inspection - Residential Passed 11/11/2020
Misc
Resolved
11/11/2020
- Foam insulation at back of house damaged and missing under door -
Deck Final Inspection - Residential Passed 11/16/2020 11/16/2020 11/16/2020
Miscellaneous Correction
Resolved
11/16/2020
-PROVIDE ENGINEERED SOLUTION FOR JOIST/LEDGER CONNECTION AT CORNERS OF HOUSE
Occupancy Inspection - Codes Residential Temporary C of O 11/16/2020 11/16/2020 11/16/2020
Misc
Corrective Action Required
10/29/2020
-Irrigation permit required -Grade must fall minimum 6” in the first 10’ from foundation, rear of structure, review 2018 IRC R403.1 -Seal all exterior penetrations, LB for irrigation electrical TCO valid through 12/16/2020
Occupancy Inspection - Codes Residential Full C of O 01/21/2021
Misc
Resolved
01/21/2021
-Irrigation permit required -Grade must fall minimum 6” in the first 10’ from foundation, rear of structure, review 2018 IRC R403.1 -Seal all exterior penetrations, LB for irrigation electrical TCO valid through 12/16/2020
Plot Plan Inspection Passed 01/21/2021
Documents & Images
Date Uploaded File Type Document Name
12/16/2019 Letter Codes Residential Plan Review
12/30/2019 Receipt Receipt for transaction: 2019-007865
12/30/2019 Letter DS Building Permit
12/30/2019 Plot Plan DOC123019
02/18/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
02/20/2020 Letter INSPECTION SUMMARY
03/03/2020 Letter Stop Work Order
03/23/2020 Engineer Report/Study 19-1168-dr-1 (Whispering Woods)
03/23/2020 Engineer Report/Study 19-1168-dr-1B (Whispering Woods)
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/18/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
08/07/2020 Engineer Report/Study Deck Pier Inspection - 1824 SW River Run Drive - Lot 11 Whispering Woods
09/16/2020 Plot Plan APPROVED AS-BUILT
09/16/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
11/09/2020 Plot Plan As Graded Plot Plan
11/11/2020 Letter INSPECTION SUMMARY
11/13/2020 2020_11_09_1824 SW River Run Dr_Lee's Summit MO_Report_Sealed
11/16/2020 Letter INSPECTION SUMMARY
11/16/2020 Letter Codes Temporary Certificate of Occupancy
01/21/2021 Letter Codes Final Certificate of Occupancy
01/21/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home