Permit Application Status

PRRES20193513


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193513
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
12/03/2019
12/05/2019
01/12/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/05/2019 12/04/2019
Kim Brennan
Property boundary
Corrective Action Required
12/03/2019

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. Bearings are not correct. Please see plat
Residential Plan Review Approved 12/05/2019 12/03/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,413.16 $1,413.16 Paid 12/05/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/05/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/05/2019
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 12/05/2019
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/05/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/05/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/05/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/08/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/28/2020 01/28/2020
Sewer Service Inspection - R Passed 2/6/2020 02/06/2020
Water Service Inspection - R Passed 2/7/2020 2/7/2020 02/07/2020
Underslab Plumbing Inspection - Residential Passed 3/2/2020 3/2/2020 03/02/2020
Erosion Control Inspection Residential Failed 5/13/2020 05/13/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/13/2020
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE -
Piers/Caissons Inspection - Residential Passed 5/13/2020 (11:00) 5/13/2020 05/13/2020
Misc
Informational
05/13/2020
(1) 24 X 36 (1) 24 x 53
All Rough Inspection - Residential Not Ready 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/29/2020
NO INSPECTION PERFORMED NO CITY APPROVED PLANS OR CITY APPROVED TRUSS PLANS ON SITE
Electrical Service Inspection Passed 7/7/2020 7/7/2020 07/07/2020
Gas Piping Inspection - Residential Passed 7/7/2020 7/7/2020 07/07/2020
Gas Service Inspection - Residential Failed 7/7/2020 7/7/2020 07/07/2020
Misc
Corrective Action Required
07/07/2020
- Gas pressure at 7 PSI - Must maintain 10 PSI for 15 minutes minimum
All Rough Inspection - Residential Failed 7/7/2020 7/7/2020 07/07/2020
Misc
Corrective Action Required
06/29/2020
- Firestop throughout all chases, bulkheads, fir outs, deadspaces at top and Fireblock vertical to horizontal - Properly Fireblock all tub traps - Attach to stud and terminate electrical box in kitchen - Secure and protect pex at showers per listed product - Secure pex at all chase locations per listed product - kitchen dining, garage entry - Seal gaps and penetration through Fireblock at HVAC, DWV chase kitchen dining, fireblock vertical to horizontal, fireblock the vertical to horizontal at chase in living room - Support DWV every 48” o.c., traps are not considered support - Garage PFH per plans - Truss hangers per plans - Anchor bolt at bottom plate with 12” of plate break in garage - Connect top plates at top stair landing at 2x6 to 2x4 wall - Provide engineered fix of double girder truss on bearing wall at bedroom #2 and hallway, not supported at ends - Firestop flue chase 2nd floor - Nail truss hangers master bed closet - Protection plate at radon 1st floor, 2nd floor laundry DWV - Solid block above lvl living room, kitchen - Address cut floor joist for DWV basement by egress window - Solid block above beam garage
All Rough Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/10/2020
- Properly Fireblock all tub traps, no light through - Secure and protect pex at showers per listed product - Secure pex at all chase locations per listed product - kitchen dining, garage entry - Support DWV every 48” o.c., traps are not considered support - Garage PFH per plans - Truss hangers per plans - Connect top plates at top stair landing at 2x6 to 2x4 wall - Provide engineered fix of double girder truss on bearing wall at bedroom #2 and hallway, not supported at ends - Protection plate at radon 1st floor, 2nd floor laundry DWV - Solid block above lvl living room, kitchen
All Rough Inspection - Residential Failed 7/13/2020 7/13/2020 07/13/2020
Misc
Corrective Action Required
07/10/2020
- Secure and protect pex at showers per listed product - 2nd floor showers - Garage PFH per plans - Truss hangers per plans - garage, 2nd floor, back patio - Connect top plates at top stair landing at 2x6 to 2x4 wall - Provide engineered fix of double girder truss on bearing wall at bedroom #2 and hallway, not supported at ends - Solid block above lvl living room, kitchen
All Rough Inspection - Residential Failed 7/15/2020 7/15/2020 07/15/2020
Misc
Corrective Action Required
07/13/2020
- Garage PFH per plans - No nuts,washers,bolts seen on triple bottom plate - Truss hangers per plans - back patio - Provide engineered fix of double girder truss on bearing wall at bedroom #2 and hallway, not supported at ends - submit engineer report on repair
All Rough Inspection - Residential Passed 7/21/2020 7/21/2020 07/21/2020
Misc
Resolved
07/21/2020
Erosion Control Inspection Residential Failed 07/21/2020
Misc
Corrective Action Required
07/21/2020
Re establish gravel filter on lot Clean mud and gravel in street
Driveway Inspection Partial 8/4/2020 8/4/2020 08/04/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 8/4/2020 8/4/2020 08/04/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 8/11/2020 8/11/2020 08/12/2020
Sidewalk Inspection Passed 8/11/2020 8/11/2020 08/12/2020
Gas Service Inspection - Residential Passed 9/14/2020 9/14/2020 09/14/2020
Occupancy Inspection - Codes Residential Failed 10/12/2020 10/12/2020 10/12/2020
Misc
Corrective Action Required
10/12/2020
-Resolve outstanding inspection fees before final c of o -Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Complete siding lid at covered patio -Security screws at backdoor -Repair drywall at hood, exposed NM -Label all dedicated outlets in garage and unfinished basement as not GFCI protected -Tempered glass required in window at bottom stair landing, south side -Non combustible attic access cover required 2nd floor
Plot Plan Inspection Passed 12/31/2020 12/31/2020 12/31/2020
Occupancy Inspection - Codes Residential Failed 12/31/2020 12/31/2020 12/31/2020
Misc
Corrective Action Required
12/31/2020
-Splash block at sump pump discharge location, minimum 36” from foundation -Seal all penetrations in siding, seal along top of meter can and AC disconnect -make water meter lid to grade, must maintain 14”-18” distance between top of meter and lid
Occupancy Inspection - Codes Residential Full C of O 1/12/2021 1/12/2021 01/12/2021
Misc
Resolved
01/12/2021
Documents & Images
Date Uploaded File Type Document Name
12/03/2019 Letter Codes Residential Plan Review
12/05/2019 Receipt Receipt for transaction: 2019-007594
12/05/2019 Letter DS Building Permit
12/05/2019 Plot Plan DOC120519-018
01/28/2020 Letter INSPECTION SUMMARY
02/06/2020 Letter INSPECTION SUMMARY
02/07/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/15/2020 82 Reserve at Stoney Creek-Truss Support
07/21/2020 Letter INSPECTION SUMMARY
07/21/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
12/08/2020 Receipt Receipt for transaction:2020-007914
12/31/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter INSPECTION SUMMARY
01/12/2021 Letter Field Certificate of Occupancy
01/12/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home