Summary
PRRES20193175
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK 4 FOOT RETAINING WALL SUSPENDED GARAGE PLOT PLAN WAS REVISED ON 12/19/19 THAT SHOWS HOUSE BEING LOWERED AS WELL AS A GRINDER PUMP BEING INSTALED - KAB
10/29/2019
11/14/2019
08/06/2021
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVE@DAVERICHARDSHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/31/2019 11/13/2019
Kim Brennan
Misc
Corrective Action Required
10/29/2019

Please add not that all grades are taken from the approved Master Drainage Plan versus the subdivision grading plans.
North arrow and scale
Corrective Action Required
10/29/2019

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.) The scaled plot plan is off by a foot
Deck location
Corrective Action Required
10/29/2019

Deck location, with dimensions to property lines must be provided on the plot plan. Deck is encroaching into the rear 30 foot setback requirement
Residential Plan Review Approved 10/31/2019 11/04/2019
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
10/29/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provide square footage for the covered deck
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/29/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance Please show egress out of all bedrooms. Bedroom #4 references the 2012 code book
Misc
Corrective Action Required
10/29/2019

Retaining Wall must be drawn, signed and stamped by a design professional
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,129.15 $1,129.15 Paid 11/14/2019
Right of Way Permit Fee $80.00 $80.00 Paid 11/14/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/14/2019
8331507-Sewer Connection Fee $540.00 $540.00 Paid 11/14/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 11/14/2019
Water Meter Fee $425.02 $425.02 Paid 11/14/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 05/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 1/29/2020 1/29/2020 at 9:55 AM 01/29/2020
Water Service Inspection - R Passed 2/4/2020 at 2:00 PM 02/04/2020
Sewer Service Inspection - R Passed 2/6/2020 (3:00) 2/6/2020 02/06/2020
Electrical Service Inspection Failed 7/16/2020 7/16/2020 07/16/2020
Misc
Corrective Action Required
07/16/2020
NO ACCESS
Gas Service Inspection - Residential Failed 7/16/2020 7/16/2020 07/16/2020
Misc
Corrective Action Required
07/16/2020
NO ACCESS
All Rough Inspection - Residential Not Ready 7/16/2020 7/16/2020 at 8:40 AM 07/16/2020
Misc
Corrective Action Required
07/16/2020
**NO ACCESS TO HOUSE. BUILDER FAILED TO PROVIDE LOCKBOX CODE. TRIED TO CALL THREE TIMES BUT NO ONE ANSWERED THE CALL. WASTED TRIP FEE ASSESSED **NO INSPECION SHALL BE GRANTED UNTIL OVERGROWN VEGETATION IS MOWED.
Electrical Service Inspection Passed 7/31/2020 7/31/2020 07/31/2020
Misc
Corrective Action Required
07/16/2020
NO ACCESS
Gas Service Inspection - Residential Passed 7/31/2020 7/31/2020 07/31/2020
Misc
Corrective Action Required
07/16/2020
NO ACCESS
All Rough Inspection - Residential Failed 7/31/2020 7/31/2020 at 8:20 AM 07/31/2020
Misc
Corrective Action Required
07/16/2020
FRAMING: -Install hangers for double ceiling joist connections above front bedroom and pantry -Fb all floor penetrations ; Fb fireplace space -Over notched ceiling joist above garage -Fb basement wall per code -Double trimmer joists at floor frame opening more than 3 ft from support (below foyer bathroom) or get engineer approval -Over notched joist above sump pump ELECTRICAL: -Provide a receptacle for foyer wall with width 3ft or more for foyer larger than 60 sq ft -Secure wiring within 8” of outdoor receptacle box behind garage -Complete electrical to fireplace -Secure and support black NM cables at max 4.5 ft interval in basement -Too many NM cables going through the wall top plate hole. DO NOT FOAM THESE 3 HOLES OR YOU HAVE TO DERATE ALL THESE CABLES -Secure and support wiring at rear basement bedroom MECHANICAL: -Seal return air penetrations throughout PLUMBING: -Slope grinder pump vent in attic toward drain; install roof flashing **OK TO INSULATE
All Rough Inspection - Residential Failed 8/10/2020 8/10/2020 at 9:10 AM 08/10/2020
Misc
Corrective Action Required
07/31/2020
-Fb all floor penetrations -Fb basement wall per code. **fb gap at vertical fireblocking and fire-blocking sheathing along the exterior wall of the bedroom -Double trimmer joists at floor frame opening more than 3 ft from support (below foyer bathroom) or get engineer approval -Over notched joist above sump pump MECHANICAL: -Seal return air penetrations throughout **not done PLUMBING: -Slope grinder pump vent in attic toward drain**not done **DO NOT FOAM THE 3 HOLES ABOVE THE SERVICE PANEL **OK TO INSULATE
Driveway Inspection Partial 8/21/2020 8/21/2020 08/21/2020
Misc
Informational
08/21/2020
8/21/20 Friday 12:00PM Driveway - forms and materials passed pre-inspection.
Driveway Inspection Passed 8/24/2020 8/24/2020 08/24/2020
Misc
Informational
08/21/2020
8/21/20 Friday 12:00PM Driveway - forms and materials passed pre-inspection.
Misc
Informational
08/24/2020
Driveway- passed final inspection.
All Rough Inspection - Residential Passed 9/1/2020 9/1/2020 at 8:25 AM 09/01/2020
Misc
Resolved
09/01/2020
-Fb all floor penetrations -Fb basement wall per code. **fb gap at vertical fireblocking and fire-blocking sheathing along the exterior wall of the bedroom -Double trimmer joists at floor frame opening more than 3 ft from support (below foyer bathroom) or get engineer approval -Over notched joist above sump pump MECHANICAL: -Seal return air penetrations throughout **not done PLUMBING: -Slope grinder pump vent in attic toward drain**not done **DO NOT FOAM THE 3 HOLES ABOVE THE SERVICE PANEL **OK TO INSULATE
Piers/Caissons Inspection - Residential Partial 9/25/2020 09/25/2020
Partial Correction
09/25/2020
TWO PIERS AT OUTER CORNERS ARE OK TO POUR; HOWEVER, CHECK IF THE PLAN CALLS FOR MIDDLE PIER TO SUPPORT FLOOR LOAD
Footing Inspection - Residential Passed 9/25/2020 09/25/2020
Informational
09/25/2020
FOOTING INSPECTED AND APPROVED BY ENGINEER
Piers/Caissons Inspection - Residential Passed 10/5/2020 (8:00) 10/5/2020 10/05/2020
Occupancy Inspection - Codes Residential Failed 5/11/2021 5/11/2021 05/11/2021
Misc
Corrective Action Required
05/11/2021
7/16/20-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
05/11/2021
**EROSION CONTROL SHALL BE INSTALLED ALONG THE REAR OF LOT AND STREET. NO FURTHER INSPECTION WILL BE GRANTED UNTIL EROSION CONTROL IS IN COMPLIANCE -Lower water lid meter to grade level -Support loose receptacle at front -Provide permanent address -As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Install deck ledger board lag screws through spacers; install support device for one deck joist near outer post; support deck posts to Simpson bases per manufacturer; bolt lower deck ledger board to foundation wall with bolts staggered per code -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Garage door not self closing -Provide wall receptacle at fireplace shelf cabinet with countertop -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen and basement wet bar countertop backsplash -Secure kitchen countertop receptacle; receptacles shall be gfci-protected -Receptacle located within 6 ft of the wet bar sink must be gfci-protected -Install locking device for basement slide doors and also secondary locking device per security code -Install breaker lock for kitchen hood and out-of-sight water heater -Provide clean out for the furnace condensate line -Provide engineer letter of inspection and approval of the suspended garage floor. Apex letter only indicates that the engineer observed structural garage slab on gravel.
Erosion Control Inspection Residential Failed 5/11/2021 05/11/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/11/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 5/19/2021 5/19/2021 05/19/2021
Misc
Corrective Action Required
05/11/2021
7/16/20-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
05/11/2021
-Not ready fee assessed on 7/16/20 has not been paid -Lower water lid meter to grade level -As-graded plot plan is required prior to sodding -Final grade, sod, downspout and sump pump extensions. Extensions min 3 ft from wall -Fix hole in exterior wall near electrical service -The grounding rod connection shall be buried (soil or concrete) -Support deck posts to Simpson bases per manufacturer; bolt lower deck ledger board to foundation wall with bolts staggered per code -Garage door not self closing **adjust door to fully closed -Receptacle located within 6 ft of the wet bar sink must be gfci-protected **the wall receptacle in front of the sink not gfci-protected -Install locking device for basement slide doors and also secondary locking device per security code -Provide engineer letter of inspection and approval of the suspended garage floor. Apex letter only indicates that the engineer observed structural garage slab on gravel.
Occupancy Inspection - Codes Residential Failed 5/20/2021 5/20/2021 05/20/2021
Misc
Resolved
05/20/2021
7/16/20-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
05/19/2021
-As-graded plot plan is required prior to sodding -Final grade and sod -Support deck posts to Simpson bases per manufacturer; bolt lower deck ledger board to foundation wall with bolts staggered per code **2 rows of 1/2" bolts at max. 24" on center, with top row min 2" below top edge. The 2 rows must be min 5" apart**; have the engineer address cut piers and the support for posts
Erosion Control Inspection Residential Passed 05/20/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/20/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2021 05/20/2021
Misc
Corrective Action Required
05/20/2021
-As-graded plot plan is required prior to sodding -Final grade and sod -Support deck posts to Simpson bases per manufacturer; bolt lower deck ledger board to foundation wall with bolts staggered per code **2 rows of 1/2" bolts at max. 24" on center, with top row min 2" below top edge. The 2 rows must be min 5" apart**; have the engineer address cut piers and the support for posts **DO NOT USE THE DECK UNTIL THE DECK ISSUE IS RESOLVED
Occupancy Inspection - Codes Residential Failed 7/27/2021 07/27/2021
Misc
Corrective Action Required
05/20/2021
-As-graded plot plan is required prior to sodding -Final grade and sod -Support deck posts to Simpson bases per manufacturer; bolt lower deck ledger board to foundation wall with bolts staggered per code **2 rows of 1/2" bolts at max. 24" on center, with top row min 2" below top edge. The 2 rows must be min 5" apart**; have the engineer address cut piers and the support for posts **DO NOT USE THE DECK UNTIL THE DECK ISSUE IS RESOLVED
Misc
Corrective Action Required
07/27/2021
No action or response from 6/23 . last email was ENG was gone and waiting for him to return. 10 NOV letter will be sent.
Occupancy Inspection - Codes Residential Full C of O 8/6/2021 08/06/2021
Misc
Resolved
08/06/2021
-As-graded plot plan is required
Misc
Resolved
08/06/2021
No action or response from 6/23 . last email was ENG was gone and waiting for him to return. 10 NOV letter will be sent.
Documents & Images
Date Uploaded File Type Document Name
10/29/2019 Letter Codes Residential Plan Review
11/14/2019 Receipt Receipt for transaction: 2019-007307
11/14/2019 Letter DS Building Permit
11/14/2019 Engineer Report/Study DOC111419-012
11/14/2019 Letter DOC111419-013
11/14/2019 Plans DOC111419-014
12/19/2019 Plot Plan Revised Plot Plan
12/26/2019 Engineer Report/Study Garys Fndn 1100 NE Goshen Ct Lee's Summit Mo Footing Forming and Reinforcement Inspection Report 12-23-19
01/29/2020 Letter INSPECTION SUMMARY
02/04/2020 Letter INSPECTION SUMMARY
02/06/2020 Letter INSPECTION SUMMARY
03/26/2020 Engineer Report/Study Final_2019.07.12_DPier_LSMO_Pat Cochran Concrete
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/24/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/20/2021 Receipt Receipt for transaction:2021-003267
05/20/2021 Engineer Report/Study Engineer report - deck 5-20-21
05/20/2021 Engineer Report/Study Final_2020.03.26_SuspGSlab_LSMO_Pat Cochran Concrete
05/20/2021 Engineer Report/Study Final_2020.03.26_SuspGSlab_LSMO_Pat Cochran Concrete
05/20/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter Codes Temporary Certificate of Occupancy
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter Codes 10 Day Letter
07/27/2021 Letter Codes 10 Day Letter
07/27/2021 Letter Codes 10 Day Letter
07/27/2021 Letter Codes 10 Day Letter
08/05/2021 RE 1100 Ne Goshen
08/06/2021 Letter Field Certificate of Occupancy
08/06/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents