Permit Application Status

PRRES20192697


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192697
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
09/20/2019
10/15/2019
06/15/2020
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
ROBERT@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/24/2019 10/02/2019
Kim Brennan
Deck location
Corrective Action Required
09/20/2019

Deck location, with dimensions to property lines must be provided on the plot plan. Please call out that this is a covered patio on the plot plan
As-graded plot plan
Corrective Action Required
09/20/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 09/24/2019 09/20/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $930.75 $930.75 Paid 10/15/2019
Right of Way Permit Fee $80.00 $80.00 Paid 10/15/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/15/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/15/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 10/15/2019
Water Meter Fee $425.02 $425.02 Paid 10/15/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/8/2019 (2:45) 11/8/2019 at 2:45 PM 11/08/2019
Underslab Plumbing Inspection - Residential Passed 11/27/2019 11/27/2019 at 9:00 AM 11/27/2019
Water Service Inspection - R Passed 11/27/2019 11/27/2019 11/27/2019
Sewer Service Inspection - R Passed 11/27/2019 11/27/2019 at 10:40 AM 11/27/2019
Piers/Caissons Inspection - Residential Passed 1/15/2020 1/15/2020 at 2:30 PM 01/15/2020
Electrical Service Inspection Passed 2/25/2020 2/25/2020 02/25/2020
Gas Service Inspection - Residential Passed 2/25/2020 2/25/2020 02/25/2020
All Rough Inspection - Residential Failed 2/25/2020 2/25/2020 at 8:55 AM 02/25/2020
Misc
Corrective Action Required
02/25/2020
FRAMING: -Fb all floor and ceiling penetrations -Fb top of return air stud space at master toilet and front bedroom -Nail corner studs in master bedroom and front bedroom -Fb fireplace space from roof. Sheathing used for Fb must be 3/4” sheathing -Shim gap under patio beam at living room corner -Fb dead spaces at stair -Brace end of lvl beam above stair -Toe nail all joists to sill plates -Provide support under split joist below front bedroom -Fb basement wall per code -Solid block lapped joists above I beam -Solid support for point load under master toilet -Provide triple stud support for lvl beam near refrigerator ELECTRICAL: -Overfilled box outside front bedroom -Move wiring min 1” from b-vent -Parallel electrical wiring inside ceiling return air outside basement bedroom. MECHANICAL: -Install double wall interconnecting fitting at common vent -Pan off return air from ceiling fur down outside basement bedroom; pan off return air from joist space above front basement bedroom (below master toilet) -Seal penetrations of return air space **DO NOT INSULATE SILL PLATES
All Rough Inspection - Residential Failed 2/27/2020 2/27/2020 at 11:05 AM 02/27/2020
Misc
Corrective Action Required
02/25/2020
-Fb fireplace space from roof. **Space still opened to the roof -Brace end of lvl beam above stair -Toe nail all joists to sill plates **Code requires 3-8d toe nails -Fb basement wall per code **Wall opened to ceiling space at basement bedroom window -Solid block lapped joists above I beam -Solid support for point load under master toilet -Protect wiring within six ft of attic access **DO NOT INSULATE SILL PLATES
All Rough Inspection - Residential Passed 2/28/2020 2/28/2020 at 9:30 AM 02/28/2020
Misc
Resolved
02/28/2020
-Fb fireplace space from roof. **Space still opened to the roof -Brace end of lvl beam above stair -Toe nail all joists to sill plates **Code requires 3-8d toe nails -Fb basement wall per code **Wall opened to ceiling space at basement bedroom window -Solid block lapped joists above I beam -Solid support for point load under master toilet -Protect wiring within six ft of attic access **DO NOT INSULATE SILL PLATES
Sidewalk Inspection Partial 4/15/2020 4/15/2020 04/15/2020
Misc
Informational
04/15/2020
Sidewalk- forms and materials passed pre-inspection.
Driveway Inspection Partial 4/15/2020 (P.M.) 4/15/2020 04/15/2020
Misc
Informational
04/15/2020
Driveway- forms and materials passed pre-inspection.
Sidewalk Inspection Passed 4/15/2020 4/15/2020 04/22/2020
Misc
Informational
04/15/2020
Sidewalk- forms and materials passed pre-inspection.
Misc
Informational
04/22/2020
Sidewalk- passed final inspection.
Occupancy Inspection - Codes Residential Failed 5/7/2020 5/7/2020 at 9:00 AM 05/07/2020
Misc
Corrective Action Required
05/07/2020
-Driveway not approved on record -Erosion control along the street must be installed prior to any occupancy approval -As-graded plot plan is required prior to sodding -The sewer tracer wire and port must be accessible at grade level -Install downspout splash blocks and downspout extensions -Install guardrail at open side of patio adjacent to window well -Provide 5/8” gb under garage boxed out wall -Open access panel to hydrotub -Tempered glass windows required at front bedroom -Cut off the excess ufer rebar -Locate and make accessible the sewer clean out -Install single plug receptacle for alarm or provide gfci protection
Plot Plan Inspection Passed 5/27/2020 05/27/2020
Driveway Inspection Passed 06/03/2020
Misc
Informational
04/15/2020
Driveway- forms and materials passed pre-inspection.
Misc
Informational
06/03/2020
Driveway - passed final inspection.
Occupancy Inspection - Codes Residential Temporary C of O 6/5/2020 6/5/2020 at 9:20 AM 06/05/2020
Misc
Corrective Action Required
05/07/2020
-Provide 5/8” gb under garage boxed out wall -Locate and make accessible the sewer clean out
Occupancy Inspection - Codes Residential Full C of O 6/15/2020 6/15/2020 06/15/2020
Misc
Informational
06/15/2020
-Provide 5/8 gb under garage boxed out wall -Locate and make accessible the sewer clean out
Documents & Images
Date Uploaded File Type Document Name
09/20/2019 Letter Codes Residential Plan Review
10/15/2019 Receipt Receipt for transaction: 2019-006805
10/15/2019 Letter DS Building Permit
10/17/2019 Plot Plan DOC101719-012
11/08/2019 Letter INSPECTION SUMMARY
11/27/2019 Letter INSPECTION SUMMARY
11/27/2019 Letter INSPECTION SUMMARY
11/27/2019 Letter INSPECTION SUMMARY
01/15/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/26/2020 Plot Plan As Graded Plot Plan
05/27/2020 Letter INSPECTION SUMMARY
06/03/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter Codes Temporary Certificate of Occupancy
06/15/2020 Letter Codes Final Certificate of Occupancy
06/15/2020 Letter Field Certificate of Occupancy
06/15/2020 Letter Codes Residential Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home